1 October 2009 in American Journal of Roentgenology
OBJECTIVE. The purpose of this study was to evaluate the degree of liver fibrosis in patients with chronic hepatitis C by use of a method in which the homogeneity of the tissue texture of the liver on B-mode ultrasound images is analyzed on the basis of results of a statistical chi-square test of the echo amplitudes. The method includes an algorithm for removing small structures, such as cross sections of the thin vessels, in the background texture to minimize differences in analysis results between users.SUBJECTS AND METHODS. Analysis was performed on images of 148 patients with histologically proven chronic hepatitis C without cirrhosis. The peak value of the \batchmode \documentclass[fleqn,10pt,legalpaper]{article} \usepackage{amssymb} \usepackage{amsfonts} \usepackage{amsmath} \pagestyle{empty} \begin{document} \(C_{m}^{2}\) \end{document} (modified chi-square distribution) histogram was calculated from B-mode ultrasound images, and the resulting value was compared with the histologic fibrosis grade.R...
1 January 2006 in Journal of Hepatology
13 July 2010 in Journal of Medical Ultrasonics
1 May 1994 in Japanese Journal of Applied Physics
Speed of sound is an important acoustic parameter for quantitative characterization of living tissues. In this paper, the relationship between speed of sound in and density of rat liver tissues are investigated. The speed of sound was measured by the nondeformable technique based on frequency-time analysis of a 3.5 MHz pulse response. The speed of sound in normal livers varied minimally between individuals and was not related to body weight or age. In liver tissues which were administered CCl4, the speed of sound was lower than the speed of sound in normal tissues. The relationship between speed of sound and density in normal, fatty and cirrhotic livers can be fitted well on the line which is estimated using the immiscible liquid model assuming a mixture of normal liver and fat tissues. For 3.5 MHz ultrasound, it is considered that the speed of sound in fresh liver with fatty degeneration is responsible for the fat content and is not strongly dependent on the degree of fibrosis.
1 May 2001 in Japanese Journal of Applied Physics
To realize quantitative diagnosis of liver cirrhosis, we have been analyzing the probability density function (PDF) of echo amplitude using B-mode images. However, the B-mode image is affected by the various signal and image processing techniques used in the diagnosis equipment, so a detailed and quantitative analysis is very difficult. In this paper, we analyze the PDF of echo amplitude using RF echo signal and B-mode images of normal and cirrhotic livers, and compare both results to examine the validity of the RF echo signal.
1 September 1992 in The Journal of the Acoustical Society of America
The sound speed in biological tissues provides important diagnostic and treatment planning information. Conventional methods of sound-speed determination generally require that transducers make physical contact with specimens in order to measure thickness and travel time in the time domain. The physical contact may cause deformation and affect blood flow and the measurement of travel time in the time domain may be sensitive to waveform distortion due to tissue inhomogeneity and surface roughness. A method for determination of the sound speed is proposed in which the sound travel time in the sample and the difference in total travel time from the transducer to the rigid reflector due to the presence of the sample are estimated in the frequency domain and which does not require physical contact of ultrasonic probes to living or freshly excised tissue specimens. Ultrasonic speed measurements in silicone rubber and acrylic resin specimens verified the method validity. The standard deviation of the measurements over a 10-×10-mm area is less than 4 m/s. Sound-speed distribution measurements of porcine muscle are in agreement with previously published results.