We present an implantable single-photon shank-based imager, monolithically integrated onto a single CMOS IC. The imager comprises of 512 single-photon avalanche diodes distributed along two shanks, with a 6-bit depth in-pixel memory and an on-chip digital-to-time converter. To scale down the system to a minimally invasive form factor, we substitute optical filtering and focusing elements with a time-gated, angle-sensitive detection system. The imager computationally reconstructs the position of fluorescent sources within a 3-D volume of 3.4 mm $\times $ 600 $\mathrm {\mu }\text{m}\,\,\times $ 400 $\mu \text{m}$ .
10 July 2020 in IEEE Transactions on Biomedical Circuits and Systems
This paper presents a device for time-gated fluorescence imaging in the deep brain, consisting of two on-chip laser diodes and 512 single-photon avalanche diodes (SPADs). The edge-emitting laser diodes deliver fluorescence excitation above the SPAD array, parallel to the imager. In the time domain, laser diode illumination is pulsed and the SPAD is time-gated, allowing a fluorescence excitation rejection up to O.D. 3 at 1 ns of time-gate delay. Each SPAD pixel is masked with Talbot gratings to enable the mapping of 2D array photon counts into a 3D image. The 3D image achieves a resolution of 40, 35, and 73 μm in the x, y, and z directions, respectively, in a noiseless environment, with a maximum frame rate of 50 kilo-frames-per-second. We present measurement results of the spatial and temporal profiles of the dual-pulsed laser diode illumination and of the photon detection characteristics of the SPAD array. Finally, we show the imager's ability to resolve a glass micropipette filled with red fluorescent microspheres. The system's 420 μm-wide cross section allows it to be inserted at arbitrary depths of the brain while achieving a field of view four times larger than fiber endoscopes of equal diameter.
Despite the advantages of optical imaging over electrophysiology, such as cell-type specificity, its application has been limited to the investigation of shallow brain regions (< 2 mm) because of the light scattering property of brain tissue. Passive optical conduits such as graded-index lenses and waveguides have permitted access to deeper locales but with restricted resolution and field of view, while creating massive lesions along the inserted path, with little pathway to improvement in the technology. As an alternative, we present the Acus device, an active implantable complementary metal-oxide-semiconductor (CMOS) neural imager with a 512-pixel silicon image sensor post- processed into a 4.1-mm-long, 120-μm-wide shank with a collinear fiber for illumination, which is able to record transient fluorescent signals in deep brain regions at 400 frames/sec. Acus can achieve single-neuron resolution in functional imaging of GCaMP6s-expressing neurons at a frame rate of 400 frames/sec.