Christopher Woods

Christopher Woods

Auto-generated profile, based on publicly available information

Christopher Woods

Atrial Fibrillation and Complex Arrhythmia Center, Sutter California Pacific Medical Center, San Francisco (C.E.W.).

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 September 2023 in JACC: Clinical Electrophysiology
Verified
Journal Article
Open access
JSJavier Sanchez
Javier Sanchez
CWChristopher Woods
Christopher Woods
JZJason Zagrodzky
Jason Zagrodzky
JNJose Nazari
Jose Nazari
MSMatthew J. Singleton
Matthew J. Singleton
MMMark Metzl
Mark Metzl
Active esophageal cooling reduces the incidence of endoscopically identified severe esophageal lesions during radiofrequency (RF) catheter ablation of the left atrium for the treatment of atrial fibrillation. A formal analysis of the atrioesophageal fistula (AEF) rate with active esophageal cooling has not previously been performed. The authors aimed to compare AEF rates before and after the adoption of active esophageal cooling. This institutional review board (IRB)-approved study was a prospective analysis of retrospective data, designed before collecting and analyzing the real-world data. The number of AEFs occurring in equivalent time frames before and after adoption of cooling using a dedicated esophageal cooling device (ensoETM, Attune Medical) were quantified across 25 prespecified hospital systems. AEF rates were then compared using generalized estimating equations robust to cluster correlation. A total of 14,224 patients received active esophageal cooling during RF ablation across the 25 hospital systems, which included a total of 30 separate hospitals. In the time frames before adoption of active cooling, a total of 10,962 patients received primarily luminal esophageal temperature (LET) monitoring during their RF ablations. In the preadoption cohort, a total of 16 AEFs occurred, for an AEF rate of 0.146%, in line with other published estimates for procedures using LET monitoring. In the postadoption cohort, no AEFs were found in the prespecified sites, yielding an AEF rate of 0% (P < 0.0001). Adoption of active esophageal cooling during RF ablation of the left atrium for the treatment of atrial fibrillation was associated with a significant reduction in AEF rate.

2 July 2024 in EP Europace
Verified
Journal Article
Open access
TATolga Aksu
Tolga Aksu
RPRoman Piotrowski
Roman Piotrowski
RTRoderick Tung
Roderick Tung
TPTom De Potter
Tom De Potter
TMTimothy M Markman
Timothy M Markman
HHHenry D. Huang
Henry D. Huang
Aims: Prior case series showed promising results for cardioneuroablation in patients with vagally induced atrioventricular blocks (VAVBs). We aimed to examine the acute procedural characteristics and intermediate-term outcomes of electroanatomical-guided cardioneuroablation (EACNA) in patients with VAVB. Methods and results: This international multicentre retrospective registry included data collected from 20 centres. Patients presenting with symptomatic paroxysmal or persistent VAVB were included in the study. All patients underwent EACNA. Procedural success was defined by the acute reversal of atrioventricular blocks (AVBs) and complete abolition of atropine response. The primary outcome was occurrence of syncope and daytime second- or advanced-degree AVB on serial prolonged electrocardiogram monitoring during follow-up. A total of 130 patients underwent EACNA. Acute procedural success was achieved in 96.2% of the cases. During a median follow-up of 300 days (150, 496), the primary outcome occurred in 17/125 (14%) cases with acute procedural success (recurrence of AVB in 9 and new syncope in 8 cases). Operator experience and use of extracardiac vagal stimulation were similar for patients with and without primary outcomes. A history of atrial fibrillation, hypertension, and coronary artery disease was associated with a higher primary outcome occurrence. Only four patients with primary outcome required pacemaker placement during follow-up. Conclusion: This is the largest multicentre study demonstrating the feasibility of EACNA with encouraging intermediate-term outcomes in selected patients with VAVB. Studies investigating the effect on burden of daytime symptoms caused by the AVB are required to confirm these findings.

27 April 2025 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
RTRoderick Tung
Roderick Tung
MPMargarida Pujol-Lopez
Margarida Pujol-Lopez
ALAndrew H. Locke
Andrew H. Locke
DADaniel M. Alyesh
Daniel M. Alyesh
SSSri Sundaram
Sri Sundaram
ADAndre D’avila
Andre D’avila

16 August 2023 in JACC: Clinical Electrophysiology
Verified
Journal Article
Closed access
KWKenneth Wong
Kenneth Wong
ASAmir A. Schricker
Amir A. Schricker
RNRidhima Nerlekar
Ridhima Nerlekar
ZFZekun Feng
Zekun Feng
SSSylvia Sudat
Sylvia Sudat
CWChristopher Woods
Christopher Woods

27 November 2022 in Expert Review of Medical Devices
Verified
Journal Article
Open access
JCJulie Cooper
Julie Cooper
CJChristopher Joseph
Christopher Joseph
JZJason Zagrodzky
Jason Zagrodzky
CWChristopher Woods
Christopher Woods
MMMark Metzl
Mark Metzl
JDJames Daniels
James Daniels
Atrial fibrillation is a condition in which the heart beats irregularly, causing symptoms such as palpitations, dizziness, shortness of breath, and chest pain. Atrial fibrillation increases the risk for stroke, heart failure, dementia, and death. One treatment for atrial fibrillation is a procedure called a catheter ablation. This procedure is minimally invasive and is performed by a specialized cardiologist, called an electrophysiologist. The electrophysiologist, or operator, uses an energy source, such as radiofrequency energy (radio waves), to stop erratic electrical signals from traveling through the heart. One complication of the catheter ablation is an inadvertent injury to the esophagus, the organ that passes food from the mouth to the stomach. If the injury is severe it may develop into an atrioesophageal fistula, which often results in death. In this review a new technology is described that helps prevent this type of injury and can provide additional benefits for the patient, operator, and hospital.

21 January 2026 in JACC
Verified
Journal Article
Open access
VRVivek Y. Reddy
Vivek Y. Reddy
HKHans Kottkamp
Hans Kottkamp
HCHugh Calkins
Hugh Calkins
DNDevi G. Nair
Devi G. Nair
PSPhilipp Sommer
Philipp Sommer
AVAtul Verma
Atul Verma
In first-in-human studies of the treatment of paroxysmal atrial fibrillation (PAF), a multielectrode globular spherical array pulsed field ablation (PFA) catheter and system able to map, pace, sense contact, and ablate exhibited a high rate, 94%, of durable pulmonary vein isolation (PVI). In this study, the authors sought to assess the 1-year outcomes of a multicenter single-arm pivotal trial of the spherical array system to treat PAF. In the multicenter PULSAR pivotal investigational device exemption trial, patients with symptomatic drug-resistant or intolerant PAF underwent PVI with the use of the spherical array system. The array catheter was used to render left atrial anatomy and voltage and perform PVI. The primary effectiveness endpoint was a composite of 12-month freedom from atrial arrhythmias (as assessed by weekly and symptomatic transtelephonic monitoring and 24-hour Holter monitoring) and freedom from other failure modes: failure to achieve PVI, repeated ablation or cardioversion, and the use of new or increased doses of class I or III antiarrhythmic drugs. The primary safety endpoint included primary adverse events within 7 days of the index ablation procedure. The study cohort of 183 patients included 19 roll-in and 164 pivotal patients: aged 65 ± 9.1 years, 40% female, CHA2DS2-VASc 2.1 ± 1.4, left atrial diameter 3.8 ± 0.6 cm. Mapping time (9.0 ± 5.5 min), transpired ablation time (25.6 ± 9.8 min), left atrial catheter dwell time (59.9 ± 11.6 min), and procedure time (95.8 ± 20.7 min) revealed an efficient procedure. Most pulmonary veins (PVs) (94%, 607/647 veins) were electrically isolated by the first pulsed field application. The primary safety event rate was 0.6% (1/164): a hemorrhagic stroke identified immediately after the procedure in a patient with severe hypertension and polycystic kidney disease. The PV stenosis substudy revealed no patients with moderate or severe vein narrowing. Primary effectiveness at 12 months was 77.8% (95% CI: 70.6%-83.9%). During redo ablation in 11 patients, 39 of 41 (95.1%) pulmonary veins remained durably isolated. The favorable clinical success observed in this multicenter Food and Drug Administration trial of this novel PFA catheter appears to reflect the clinical success achievable with durable PVI in PAF patients. (Safety and Effectiveness of the Globe Pulsed Field System for Treating Patients with Symptomatic Paroxysmal or Persistent Atrial Fibrillation [PULSAR]; NCT05462145).