Marcos Rogério Széliga

Marcos Rogério Széliga

Auto-generated profile, based on publicly available information

Marcos Rogério Széliga

Universidade Estadual de Ponta Grossa, Brazil

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Engenharia Sanitaria e Ambiental
Verified
Journal Article
Open access
LWLuiz Fernando Wagner
Luiz Fernando Wagner
GWGiovana Wiecheteck
Giovana Wiecheteck
MSMarcos Rogério Széliga
Marcos Rogério Széliga
RESUMO O objetivo deste trabalho foi analisar a disposição do lodo do decantador de uma estação de tratamento de água (ETA) com sedimentação lastreada por microareia (Actiflo®) em uma estação de tratamento de esgoto (ETE) composta de upflow anaerobic sludge blanket (UASB) e lagoa de polimento, em Ponta Grossa, Paraná. A ETE Verde operou em condição estável, com uma vazão média afluente de 213,14 L.s-1. Os UASBs operaram com tempo de detenção hidráulica (TDH) de 9,9 horas, carga hidráulica volumétrica de 2,4 m3.m-3.d-1 e carga orgânica volumétrica (COV), em função da demanda química de oxigênio (DQO), variando entre 0,75 e 1,66 kgDQO.m-3.d-1. A lagoa operou com TDH de 4,5 dias, com taxa de aplicação superficial variando entre 765 e 2.872 kgDQO.ha-1.d-1 e COV variando entre 19 e 72 gDQO.m-3.d-1. A eficiência na remoção de DQO e sólidos suspensos totais (SST) foi mantida, mesmo com o lançamento do lodo da ETA. A eficiência da ETE variou entre 80 e 86% para a remoção de DQO e entre 92 e 96% para a remoção de SST. Concluiu-se que o lançamento na rede de esgotos é uma alternativa viável de disposição do lodo do decantador da ETA Actiflo®.

1 January 2020 in Engenharia Sanitaria e Ambiental
Verified
Journal Article
Open access
PDF file
JAJuliano Penteado de Almeida
Juliano Penteado de Almeida
AKAna Carolina Barbosa Kummer
Ana Carolina Barbosa Kummer
GCGabriel Carranza
Gabriel Carranza
Luiza C. CamposLuiza C. Campos
Luiza C. Campos
MSMarcos Rogério Széliga
Marcos Rogério Széliga
GWGiovana Wiecheteck
Giovana Wiecheteck
RESUMO Com a escassez da disponibilidade de água doce e o aumento da demanda de água no mundo e no Brasil, uma das alternativas são os sistemas de dessalinização de água, que removem os sais das águas salobra ou salgada. Este estudo teve como objetivo avaliar a eficiência de um sistema piloto de dessalinização de água salobra a qual foi obtida a partir da mistura de águas do mar e de rio até atingir concentração de sólidos dissolvidos totais (SDT) de 1.500 mg.L-1. O sistema piloto de dessalinização, com capacidade de 1,0 m3.h-1, é composto de ultrafiltração (UF) e abrandamento como pré-tratamento à osmose reversa (OR). Foram realizadas análises de qualidade da água na entrada e saída das unidades de tratamento relativas a SDT, condutividade elétrica, turbidez, pH, cor aparente, alcalinidade, dureza total, cálcio, magnésio, cloreto, sulfato e temperatura. Foram avaliadas a pressão osmótica, o fluxo de filtração e a taxa de recuperação de água no sistema de OR. Com os resultados obtidos, conclui-se que a eficiência de remoção de SDT e condutividade foi de 99%. A UF foi eficiente na remoção de turbidez, enquanto a OR apresentou maiores eficiências de remoção de sais. O sistema piloto de tratamento foi capaz de remover todos os parâmetros estudados. A taxa de recuperação na OR foi de 74,64%.

9 October 2025 in Environmental Technology
Verified
Journal Article
Closed access
GSGuilherme Sandaka
Guilherme Sandaka
MPMaritane Prior
Maritane Prior
MSMarcos Rogério Szeliga
Marcos Rogério Szeliga
AKAna Carolina Barbosa Kummer
Ana Carolina Barbosa Kummer
EMErivelto Mercante
Erivelto Mercante
JSJair Antônio Cruz Siqueira
Jair Antônio Cruz Siqueira
Wetlands are commonly used for wastewater treatment, with table salt frequently used as a tracer. This study aimed to evaluate the behaviour of table salt as a tracer for hydrodynamic characterization of wetlands using low-cost Arduino sensors to collect data and computational imaging to monitor the flow in a laboratory-scale wetland. A 100 L circular-shaped tank filled with gravel was used, and sampling points were placed at 56 different points. Five tests were conducted: three with only water in the tank, and two with water and a 0.27 m coarse aggregate layer (void ratio 45%, typical for wetlands). Water-only tests used a flow rate of 7.2 L·h-1 for an ascendant configuration, and 3.6 and 7.2 L·h-1 for a descendant configuration. Hydraulic diagnosis data were collected from electrical signals by electrodes in the circulation tank using the signal conductivity-concentration correlation. To analyse the tracer plume evolution over time, a control volume was created using processing software. For different tank levels, concentration curves, and hydraulic efficiency parameters, including short circuit, hydraulic efficiency (λ), theoretical residence time (tn), and average residence time (tm), were calculated. Colour map graphs exhibited densimetric deposition of the tracer at the bottom of the tank for all tested flow configurations. The imagery showed the behaviour of table salt as a tracer, highlighting deposition and diffusion for the tested configurations. The imaging method obtained in this study may be applied to other studies and adapted to different scenarios.

1 January 2023 in Engenharia Sanitaria e Ambiental
Verified
Journal Article
Open access
PDF file
MPMeiryellen Cristina Vargas Proença
Meiryellen Cristina Vargas Proença
MSMarcos Rogério Széliga
Marcos Rogério Széliga
A escassez de água disponível tem gerado a necessidade da utilização de fontes alternativas de água para abastecimento público. Neste trabalho foi avaliada a eficiência do sistema de bancada por batelada no tratamento por coagulação, floculação, sedimentação e filtração (CFS-F) seguido de eletrodiálise (ED) no tratamento de água salobra, a fim de propor uma alternativa para a dessalinização. A água salobra (afluente do sistema de tratamento proposto) possuía concentrações de 1.000, 2.000 e 3.000 ± 180 mg.L-1 de sólidos dissolvidos totais (SDT). O tratamento convencional consistia em CFS-F com cloreto de polialumínio como coagulante, sendo a dosagem previamente ajustada por ensaios de Jar Test. A CFS-F removeu sólidos suspensos totais (20,02 a 99,99%), turbidez (78,13 a 98,45%) e cor aparente (85,05 a 99,99%), porém não ocorreu alteração da concentração de SDT. A ED foi eficiente na redução de 90,01, 94,72 e 96,73% de SDT do diluído para as concentrações afluentes de 1.000, 2.000 e 3.000 ± 180 mg.L-1 de SDT, respectivamente. Para obter diluído efluente pelo sistema proposto com concentração de SDT menor que 100 mg.L-1, observou-se maior tempo de tratamento para as maiores concentrações de SDT afluente à ED. No entanto, quanto maior o teor de SDT de diluído e concentrado afluente maior a corrente elétrica correspondente ao aplicar tensão constante de 30 V. Isso demonstra que a concentração de SDT dentro do equipamento de ED influencia a corrente elétrica que, por sua vez, aumenta a taxa de fluxo de íons do diluído para o concentrado, amenizando o fator tempo de tratamento para as maiores concentrações de SDT afluentes.