28 February 2024 in Clinical Oral Implants Research
Purpose: Investigate survival and technical complications of two‐unit posterior implant‐supported cantilever made of monolithic zirconia on titanium‐base abutments (Zr‐TiB) vs. porcelain‐fused‐to‐metal on castable gold abutments (PFM‐GA) using two different implant connections, internal butt‐joint (IBJ) and internal conical (IC).Materials and Methods: Forty‐eight implants (4.3 mm diameter) were divided into four groups (n = 12) to support 2‐unit mandibular premolar cantilevers with two different materials (Zr‐TiB vs. PFM‐GA) and two connection types (IBJ vs. IC). Tested groups were as follows: (1) IBJ/Zr‐TiB; (2) IBJ/PFM‐GA; (3) IC/Zr‐TiB; and (4) IC/PFM‐GA. Specimens were thermomechanical aged (1,200,000 cycles, 98 N, 5–55°C) with occlusal axial load on the pontic. Catastrophic and non‐catastrophic events were registered, and removal torque values measured before and after aging. Specimens surviving aging were subjected to loading until failure. Survival, total complication rates, torque loss (%), and bending moments were calculated.Results: From 48 specimens, 38 survived aging. Survival rates significantly varied from 16.7% (IC/PFM‐GA) to 100% (IBJ/Zr‐TiB; IBJ/PFM‐GA; IC/Zr‐TiB) (p < .01). Internal conical connection revealed significantly higher torque loss (IC/ZrTiB – 67%) compared to internal butt‐joint (IBJ/Zr‐TiB – 44%; IBJ/PFM‐GA – 46%) (p < .01). Bending moments were higher in internal butt‐joint connections than in internal conical (p < .05).Conclusion and Clinical Implications: Two‐unit posterior implant‐supported cantilever FDPs replacing mandibular premolars composed of monolithic zirconia on titanium‐base abutments demonstrated higher mechanical stability compared to porcelain‐fused‐to‐metal on castable gold abutments in this in vitro study. The internal conical connection combined with porcelain‐fused‐to‐metal on gold abutments revealed a high number of failures; therefore, their clinical use may be considered cautiously for this indication.
7 July 2025 in Journal of Prosthodontics
Purpose: To evaluate the fracture load and retention of subtractively manufactured interim restorations for single‐unit implants of two diameters, using three interim abutment types: stock abutments, titanium base (Ti‐base) abutments, and pre‐milled polymethyl methacrylate (PMMA) abutments.Materials and Methods: A total of 90 milled PMMA interim restorations were fabricated on three abutment types: (1) cement‐retained restorations on stock abutments (stock group), (2) screw‐retained restorations on Ti‐base abutments (Ti‐base group), and (3) screw‐retained restorations fabricated on pre‐milled PMMA abutments (pre‐milled PMMA group). For fracture load testing, 60 restorations were allocated across implants with two diameters (Ø3.5 mm and Ø4.5 mm), forming six groups (n = 10 per group). Crown retention was evaluated by pull‐out testing following cyclic loading on 30 restorations (n = 10 per abutment type), and failure modes were recorded. Statistical analyses were conducted (α = 0.05).Results: The Ø4.5‐mm implants exhibited higher fracture loads than the Ø3.5‐mm implants (p < 0.001). For both implant diameters, the pre‐milled PMMA group had significantly lower fracture loads than the stock and Ti‐base groups (p < 0.05). Nevertheless, all groups’ fracture loads were significantly higher than the reported maximum occlusal force (p < 0.001). The pre‐milled PMMA group demonstrated the highest pull‐out force, significantly exceeding that of the stock and Ti‐base groups (p < 0.001).Conclusions: The pre‐milled PMMA group demonstrated superior retention but lower fracture load than the stock and Ti‐base groups. The Ø4.5‐mm implants exhibited higher fracture loads compared to the Ø3.5‐mm implants. Despite the lower fracture load of the pre‐milled PMMA group, all three abutment types surpassed the reported maximum occlusal force.
18 November 2025 in Journal of Dentistry
6 June 2026 in The Journal of Prosthetic Dentistry
14 December 2025 in Journal of Dentistry