Detection of X- and gamma-rays is essential to a wide range of applications from medical imaging to high energy physics, astronomy, and homeland security. Cadmium zinc telluride (CZT) is the most widely used material for room-temperature detector applications and has been fulfilling the requirements for growing detection demands over the last three decades. However, CZT still suffers from the presence of a high density of performance-limiting defects, such as sub-grain boundary networks and Te inclusions. Cadmium zinc telluride selenide (CZTS) is an emerging material with compelling properties that mitigate some of the long-standing issues seen in CZT. This new quaternary is free from sub-grain boundary networks and possesses very few Te inclusions. In addition, the material offers a high degree of compositional homogeneity. The advancement of CZTS has accelerated through investigations of the material properties and virtual Frisch-grid (VFG) detector performance. The excellent material quality with highly reduced performance-limiting defects elevates the importance of CZTS as a potential replacement to CZT at a substantially lower cost.
We utilized a low-temperature spatially resolved micro-photoluminescence mapping technique to investigate the spatial variation of photoluminescence- and electronic-defect states in areas of CdZnTe (CZT) single crystals containing structural-imperfections. Photoluminescence mapping of the donor-bound-exciton emission reveals an unexpected blue-shift of the CZT bandgap at Te inclusions, which indicates that for optical measurements the localized strain field needs to be considered for accurate calculation of Zn composition and energy levels near micro-scale defects. We observed that the line widths of the donor-bound-exciton peak and defect-related D band are broadened in regions with a high density of dislocations; in contrast, the donor-acceptor-pair peak is narrowed.
Pixelated semi-conductor detectors providing high energy resolution enable parallel acquisition of x-ray fluorescence (XRF) signals, potentially leading to performance enhancement of benchtop XRF imaging or computed tomography (XFCT) systems utilizing ordinary polychromatic x-ray sources. However, little is currently known about the characteristics of such detectors under typical operating conditions of benchtop XRF imaging/XFCT. In this work, a commercially available pixelated cadmium telluride (CdTe) detector system, HEXITEC (High Energy X-ray Imaging Technology), was characterized to address this issue. Specifically, HEXITEC was deployed into our benchtop cone-beam XFCT system, and used to detect gold $\text{K}\alpha $ XRF photons from gold nanoparticle (GNP)–loaded phantoms. To facilitate the detection of XRF photons, various parallel-hole stainless steel collimators were fabricated and coupled with HEXITEC. A pixel-by-pixel spectrum merging algorithm was introduced to obtain well-defined XRF + scatter spectra with parallel-hole collimators. The effect of charge sharing addition (CSA) and discrimination (CSD) algorithms was also investigated for pixel-level CS correction. Finally, the detector energy resolution, in terms of the full-width at half-maximum (FWHM) values at two gold $\text{K}\alpha $ XRF peaks (~68 keV), was also determined. Under the current experimental conditions, CSD provided the best energy resolution of HEXITEC (~1.05 keV FWHM), compared with CSA and no CS correction. This FWHM value was larger (by up to ~0.35 keV) than those reported previously for HEXITEC (at ~60 keV Am-241 peak) and single-crystal CdTe detectors (at two gold $\text{K}\alpha $ XRF peaks). This investigation highlighted characteristics of HEXITEC as well as the necessity for application-specific detector characterization.
Nuclear detectors for x-ray and gamma-ray spectroscopy and imaging are a vital tool in many homeland security, medical imaging, astrophysics and other applications. Most of these applications require room-temperature operation due to the operational constraints imposed by a cryogenic cooling system. CdZnTe (CZT) has been the main material with the desired detection properties, and CZT crystals have been used commercially for three decades. However, CdZnTe still suffers from long-standing issues of high densities of performance-limiting intrinsic defects such as Te inclusions and networks of dislocation walls (sub-grain boundaries). A recently invented new quaternary material CdZnTeSe showed excellent material properties for radiation detection. The material was found to be free from dislocation networks, possess reduced Te inclusions, and have better compositional homogeneity. Virtual Frisch grid detectors were fabricated from crystals taken from a CdZnTeSe ingot that was grown by the traveling heater method. The detectors were fabricated from an as-grown ingot, bypassing the post-growth annealing process commonly practiced for industrial-grade CZT. The performances of the detectors were studied with different Frisch grid lengths using an amplifier shaping time ranging from 1–6 µs. The detectors showed high-quality spectroscopic performance with an as-measured energy resolution of ~1.1% at 662 keV for an optimum Frisch grid length of 3 mm. The charge collection was observed to enhance for longer Frisch grids.
Frisch-ring CdZnTe detectors have demonstrated good energy resolution for identifying isotopes, <1% FWHM at 662 keV, and good efficiency for detecting gamma rays. We will fabricate and test at Brookhaven National Laboratory an integrated module of a 64-element array of 6times6times12 mm 3 Frisch-ring detectors, coupled with a readout electronics system. It supports 64 readout channels, and includes front-end electronics, signal processing circuit, USB interface and high-voltage power supply. The data-acquisition software is used to process the data stream, which includes amplitude and timing information for each detected event. This paper describes the design and assembly of the detector modules, readout electronics, and a conceptual prototype system. Some test results are also reported.