Alafate Kahaer

Alafate Kahaer

Auto-generated profile, based on publicly available information

Alafate Kahaer

The First Affiliated Hospital of Xinjiang Medical University

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 February 2024 in Global Spine Journal
Verified
Journal Article
Open access
YWYixi Wang
Yixi Wang
AMAbulikemu Maimaiti
Abulikemu Maimaiti
ATAbudusalamu Tuoheti
Abudusalamu Tuoheti
YXYang Xiao
Yang Xiao
RZRui Zhang
Rui Zhang
PRPaerhati Rexiti
Paerhati Rexiti
Study Design: Review. Objective: Unilateral Biportal Endoscopy (UBE) is a minimally invasive surgery that is gaining recognition and being employed in clinical practice. Nevertheless, the precise method for determining UBE portals’ location varies depending on the originator’s preferences or the anatomical structure’s proximity to the portal positions. Consequently, the relationship among UBE portals' locations is messy. This study aims to elaborate on the specific portal localization and explore the positional association and commonality among different UBE approaches’ portals. Methods: The following keywords are used to search in the PubMed, Ovid, Web of Science, ScienceDirect, SpringerLink, Scopus, CNKI, and Wanfang database: “Biportal endoscopic spinal surgery”, “Two portal endoscopic spinal surgery”, “Percutaneous biportal endoscopic decompression”, “Unilateral biportal endoscopy”, “Irrigation endoscopic discectomy”, “UBE” and “BESS”. Results: After screening, 29 pieces of literature are included. The study summarizes different UBE approach portal localizations, categorized by fusion or non-fusion surgery and pathological classification. The study presents an inaugural method for categorizing the lumber into four surgical intervals based on bone landmarks and assigns different UBE approaches to the appropriate intervals based on their characteristics, making the selection of UBE surgical approaches’ portal locations more flexible. Additionally, the study provides an overview of the indications, complications, and distinct benefits associated with each interval, further refining the novel UBE portal interval localization method. Conclusion: The study clarifies the interrelationship and commonality between the portals of different UBE approaches and proposes a new UBE portal interval localization method to enhance surgeons’ understanding and proficiency in UBE procedures.

28 March 2022 in Journal of Healthcare Engineering
Verified
Journal Article
Open access
PDF file
AKAlafate Kahaer
Alafate Kahaer
ZZZhihao Zhou
Zhihao Zhou
JMJulaiti Maitirouzi
Julaiti Maitirouzi
SWShuiquan Wang
Shuiquan Wang
WSWenjie Shi
Wenjie Shi
PRPaerhati Rexiti
Paerhati Rexiti
There is no detailed biomechanical research about the hybrid CBT-TT (CBT screws at cranial level and TT screws at caudal level) and TT-CBT (TT screws at cranial level and CBT screws at caudal level) techniques with finite element (FE) method. Therefore, the purpose of this study was to evaluate and provide specific biomechanical data of the hybrid lumbar posterior fixation system and compare with traditional pedicle screw and cortical screw trajectories without fusion, in FE method. Specimens were from the anatomy laboratory of Xinjiang Medical University. Four FE models of the L4-L5 lumbar spine segment were generated. For each of these, four implanted models with the following instruments were created: bilateral traditional trajectory screw fixation (TT-TT), bilateral cortical bone trajectory screw fixation (CBT-CBT), hybrid CBT-TT fixation, and hybrid TT-CBT fixation. A 400 N compressive load with 7.5 Nm moments was applied so as to simulate flexion, extension, left lateral bending, right lateral bending, left rotation, and right rotation, respectively. The range of motion (ROM) of the L4-L5 segment and the posterior fixation, the von Mises stress of the intervertebral disc, and the posterior fixation in four implanted models were compared. CBT-TT displayed a lower ROM of the fixation segment (3.82 ± 0.633°) compared to TT-TT (4.78 ± 0.306°) and CBT-CBT (4.23 ± 0.396°). In addition, CBT-TT showed a lower ROM of the posterior fixation (0.595 ± 0.108°) compared to TT-TT (0.795 ± 0.103°) and CBT-CBT (0.758 ± 0.052°). The intervertebral disc stress of CBT-TT (4.435 ± 0.604 MPa) was lower than TT-TT (7.592 ± 0.387 MPa) and CBT-CBT (6.605 ± 0.600 MPa). CBT-TT (20.228 ± 3.044 MPa) and TT-CBT (12.548 ± 2.914 MPa) displayed a lower peak von Mises stress of the posterior fixation compared to TT-TT (25.480 ± 3.737 MPa). The hybrid CBT-TT and TT-CBT techniques offered superior fixation strength compared to the CBT-CBT and TT-TT techniques.

1 June 2022 in Revista da Associação Médica Brasileira
Verified
Journal Article
Open access
PRPaerhati Rexiti
Paerhati Rexiti
DADilimulati Aikeremu
Dilimulati Aikeremu
SWShuiquan Wang
Shuiquan Wang
NANueraihemaiti Abuduwali
Nueraihemaiti Abuduwali
AKAlafate Kahaer
Alafate Kahaer
SWSheng Weibing
Sheng Weibing
To reduce surgical exposure and improve accuracy, this study evaluated the anatomical distance parameter D (including D1, D2, and D3) of the lumbar isthmus for cortical bone screw insertion. A total of 25 structurally complete lumbar dry specimens were used for lumbar anatomy measurements. The six cadaver specimens were divided into upper and lower parts on the plane of the T11–T12 vertebrae, and we use the lower parts. Therefore, six lumbar wet specimens and another four complete lumbar dry specimens were selected. The lumbar isthmus tangent point was considered a coordinate origin, and the insertion point was determined through translating the distance of D1 value to the midline of the vertebral body horizontally and then vertically moved toward inferior board of the transverse process with the distance of D3 value. In four dry and six wet intact lumbar specimens, cortical bone screws were placed according to the average value of the isthmus parameter D. A total of 100 trajectories were verified in specimens by X-ray and computed topography scan to evaluate the safety, accuracy, and feasibility of the surgical use of isthmus parameter D. Using this parameter, the rates of excellent screw placement were 95% (38/40) in four dry specimens and 88.7% (53/60) in six wet specimens. The isthmus parameter D is easier to use by the operator, which can improve surgical accuracy and reduce operation time. Level IV, prospective study.