Shanfang Huang

Shanfang Huang

Auto-generated profile, based on publicly available information

Shanfang Huang

Department of Engineering Physics, Tsinghua University, Beijing 100084, China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
YMYugao Ma
Yugao Ma
Shichang LiuShichang Liu
Shichang Liu
ZLZhen Luo
Zhen Luo
SHShanfang Huang
Shanfang Huang
KLKaiwen Li
Kaiwen Li
HYHongxing Yu
Hongxing Yu

1 December 2021 in Nuclear Engineering and Design
Verified
Journal Article
Closed access
YMYugao Ma
Yugao Ma
WHWenbin Han
Wenbin Han
BXBiheng Xie
Biheng Xie
HYHongxing Yu
Hongxing Yu
MLMinyun Liu
Minyun Liu
XCXiaoming Chai
Xiaoming Chai

21 March 2023 in Applied Thermal Engineering
Verified
Journal Article
Closed access
YMYugao Ma
Yugao Ma
HYHongxing Yu
Hongxing Yu
XWXueqing Wang
Xueqing Wang
YZYingnan Zhang
Yingnan Zhang
SHShanfang Huang
Shanfang Huang
XCXiaoming Chai
Xiaoming Chai

1 September 2018 in Experimental Thermal and Fluid Science
Verified
Journal Article
Closed access
YPYanzhi Pan
Yanzhi Pan
YMYugao Ma
Yugao Ma
SHShanfang Huang
Shanfang Huang
PNPengman Niu
Pengman Niu
DWDong Wang
Dong Wang
JXJianhua Xie
Jianhua Xie

1 January 2015 in Science and Technology of Nuclear Installations
Verified
Journal Article
Open access
PDF file
DGDaxin Gong
Daxin Gong
SHShanfang Huang
Shanfang Huang
GWGuanbo Wang
Guanbo Wang
KWKan Wang
Kan Wang
Heat transfer characteristics of fuel assemblies for a high flux research reactor with a neutron trap are numerically investigated in this study. Single-phase turbulence flow is calculated by a commercial code, FLUENT, where the computational objective covers standard and control fuel assemblies. The simulation is carried out with an inlet coolant velocity varying from 4.5 m/s to 7.5 m/s in hot assemblies. The results indicate that the cladding temperature is always lower than the saturation temperature in the calculated ranges. The temperature rise in the control fuel assembly is smaller than that of the standard fuel assembly. Additionally, the assembly with a hot spot is specially studied, and the safety of the research reactor is also approved.

1 March 2020 in Annals of Nuclear Energy
Verified
Journal Article
Closed access
QPQingquan Pan
Qingquan Pan
JRJunjie Rao
Junjie Rao
SHShanfang Huang
Shanfang Huang
KWKan Wang
Kan Wang