Audio sources are ubiquitously available on portable electronic devices, including cell phones. Here we demonstrate lysis of Mycobacterium marinum and Staphylococcus epidermidis bacteria utilizing a portable audio device coupled with a simple and inexpensive electromagnetic coil. The resulting alternating magnetic field rotates a magnet in a tube with the sample and glass beads, lysing the cells and enabling sample preparation for these bacteria anywhere there is a cell phone, mp3 player, laptop, or other device with a headphone jack.
We present a proof-of-concept design and preliminary data to demonstrate a novel syringe infusion pump that is low cost, nonelectric, reusable, and adjustable. This device addresses the need for infusion therapy in low- and middle-income countries (LMIC), where intermittent electrical power precludes the use of conventional electronic infusion pumps and limited financial resources make high costs of disposable infusion pumps impractical. Our design uses a pneumatically pressurized, hydraulic (air over oil) drive piston coupled to a closed-circuit flow restriction to drive a syringe plunger at a constant velocity, thus providing a constant volumetric flow rate to the patient. The device requires no proprietary or precision consumables, significantly reducing treatment costs compared with other methods. The highly adjustable device provides constant flow rates across the range of 0.5–8 mL/h when used with a 30-mL syringe. The user interface is simple and intuitive; the hardware is robust and portable. This novel technology platform has broad applications in addressing priority health needs in LMIC.
1 June 2021 in Medical Devices: Evidence and Research
Purpose: Infusion pumps are the preferred method for intravenous delivery of drugs and fluids, and an essential tool in health facilities. Their high cost, complexity and reliance on electricity pose serious challenges to wide-spread use, availability and access in low- and middle-income countries. PATH developed the RELI Delivery System (RELI), a low cost, non-electric infusion pump to address these challenges. Input collected from fifty-nine newborn and maternal care providers and from seven national level decision makers in Uganda was used to guide product development, further informing product design requirements, and optimal design features to best serve their needs. Methods: A formative evaluation following a mixed methods approach including focus group discussions (FGDs), stakeholder interviews, and observations was used to collect data from end users. Results: Stakeholders provided critical input on the RELI prototype design features, safety criteria, and contexts of use of infusion pumps, as well as recommendations for design refinements. Infusion systems are greatly needed but not readily available and their use is limited to well-resourced higher level facilities, even though the need is high in non-tertiary care hospital where patient volume is high, resources are scarce, power is inconsistent, and facilities are understaffed and overcrowded. Users expressed a need for an affordable and simple device with an intuitive user interface, clear instructions for use, and basic safety features. Conclusion: The study provided important guidance for further design refinements based on input from respondents and confirmed the need for robust, affordable, infusion pumps that meet the requirements for use in low-resource settings.
Background: Preterm birth and resulting respiratory failure is a leading cause of newborn death- the majority of which occur in resource-constrained settings and could be prevented with bubble continuous positive airway pressure (bCPAP). Commercialized devices are expensive, however, and sites commonly use improvised devices utilizing 100% oxygen which can cause blindness. To address this, PATH and a multidisciplinary team developed a very low-cost bCPAP device including fixed-ratio oxygen blenders. Objective: We assessed feasibility of use of the device on neonatal patients as well as the usability and acceptability of the device by healthcare workers. This study did not evaluate device effectiveness. Methods: The study took place in a Ugandan level two unit. Neonates with respiratory failure were treated with the bCPAP device. Prospective data were collected through observation as well as likert-style scales and interviews with healthcare workers. Data were analyzed using frequencies, means and standard deviation and interviews via a descriptive coding method. Retrospectively registered via ClinicalTrials.gov number NCT05462509. Results: Fourteen neonates were treated with the bCPAP device in October—December 2021. Patients were born onsite (57%), with median weight of 1.3 kg (IQR 1–1.8). Median treatment length was 2.5 days (IQR 2–6). bCPAP was stopped due to: improvement (83%) and death (17%). All patients experienced episodes of saturations >95%. Median time for device set up: 15 minutes (IQR 12–18) and changing the blender: 15 seconds (IQR 12–27). After initial device use, 9 out of 9 nurses report the set-up as well as blender use was “easy” and their overall satisfaction with the device was 8.5/10 (IQR 6.5–9.5). Interview themes included the appreciation for the ability to administer less than 100% oxygen, desire to continue use of the device, and a desire for additional blenders. Conclusions: In facilities otherwise using 100% oxygen, use of the bCPAP device including oxygen blenders is feasible and acceptable to healthcare workers. Trial registration: ClinicalTrials.gov, Identifier NCT05462509.
1 June 2022 in Medical Devices: Evidence and Research
Purpose: Bubble continuous positive airway pressure (bCPAP) is often used to treat respiratory distress experienced by some 15 million preterm infants born globally every year. In low- and middle-income countries, improvised bCPAP devices are used, often without a blender that protects the infant from the sequelae of excessive oxygen exposure. Materials and Methods: The aim of this bench testing was to assess the mechanical safety and performance of the PATH bCPAP and blenders device, which provides a stable and reliable source of pressurized blended gas without the requirement for a source of compressed medical air or electricity. The device includes two fixed ratio blenders: a “low” blend that provides 37% oxygen and a “high” blend that provides 60% oxygen. We performed bench testing to characterize the performance of the bCPAP and blenders, including respiratory circuit verification, blender verification, conditioned humidity testing, and sound measurement. Results: Test results for all performance variables met the acceptance criteria of our product requirement specification. The device provides a fixed ratio of air and oxygen that is consistent over the entire range of clinically relevant pressures (4 to 8 cmH2O) and remains consistent despite changes in flow (2 to 7 liters per minute). The blend is stable within ± 5% of the blenders’ nominal blend ratio when used with a 100% oxygen source, irrespective of the flow and pressure from the oxygen source or the flow and pressure of the blended gas delivered to the neonate. Sound and humidity test results were within specifications. Conclusion: This very low-cost nonelectric bCPAP and blenders device is optimally designed to deliver a stable and reliable source of pressurized blended gas.
23 November 2016 in International Journal of Pediatrics
Hypoxemia is a complication of pneumonia—the leading infectious cause of death in children worldwide. Treatment generally requires oxygen-enriched air, but access in low-resource settings is expensive and unreliable. We explored use of reservoir cannulas (RCs), which yield oxygen savings in adults but have not been examined in children. Toddler, small child, and adolescent breathing profiles were simulated with artificial lung and airway models. An oxygen concentrator provided flow rates of 0 to 5 L/min via a standard nasal cannula (NC) or RC, and delivered oxygen fraction (FdO2) was measured. The oxygen savings ratio (SR) and absolute flow savings (AFS) were calculated, comparing NC and RC. We demonstrated proof-of-concept that pendant RCs could conserve oxygen during pediatric therapy. SR mean and standard deviation wereto,to, andtofor toddler, small child, and adolescent models, respectively. Maximum AFS observed were,, and L/min for the same models. RCs have the potential to reduce oxygen consumption during treatment of hypoxemia in children; however, further evaluation of products is needed, followed by clinical analysis in patients.