Thiago Nogueira Costa

Thiago Nogueira Costa

Auto-generated profile, based on publicly available information

Thiago Nogueira Costa

Universidade de São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)
Verified
Journal Article
Open access
TCThiago Nogueira Costa
Thiago Nogueira Costa
Francisco TustumiFrancisco Tustumi
Francisco Tustumi
LFLucas Sousa Maia Ferros
Lucas Sousa Maia Ferros
BCBárbara Buccelli Colonno
Bárbara Buccelli Colonno
RARicardo Zugaib Abdalla
Ricardo Zugaib Abdalla
ICIvan Cecconello
Ivan Cecconello
BACKGROUND: Robotic-assisted surgery research has grown dramatically in the past two decades and the advantages over traditional videolaparoscopy have been extensively debated. For hernias, the robotic system can increase intraoperative strategies, especially in complex hernias or incisional hernias. AIMS: This study aimed to compare the direct cost differences between robotic and laparoscopic hernia repair and determine each source of expenditure that may be related to the increased costs in a robotic program from the perspective of a Brazilian public institution. METHODS: This study investigated the differences in direct costs from the data generated from a trial protocol (ReBEC: RBR-5s6mnrf). Patients with incisional hernia were randomly assigned to receive laparoscopic ventral incisional hernia repair (LVIHR) or robotic ventral incisional hernia repair (RVIHR). The direct medical costs of hernia treatment were described in the Brazilian currency (R$). RESULTS: A total of 19 patients submitted to LVIHR were compared with 18 submitted to RVIHR. The amount spent on operation room time (RVIHR: 2,447.91±644.79; LVIHR: 1,989.67±763.00; p=0.030), inhaled medical gases in operating room (RVIHR: 270.57±211.51; LVIHR: 84.55±252.34; p=0.023), human resources in operating room (RVIHR: 3,164.43±894.97; LVIHR: 2,120.16±663.78; p<0.001), material resources (RVIHR: 3,204.32±351.55; LVIHR: 736.51±972.32; p<0.001), and medications (RVIHR: 823.40±175.47; LVIHR: 288.50±352.55; p<0.001) for RVIHR was higher than that for LVIHR, implying a higher total cost to RVIHR (RVIHR: 14,712.24±3,520.82; LVIHR: 10,295.95±3,453.59; p<0.001). No significant difference was noted in costs related to the hospital stay, human resources in intensive care unit and ward, diagnostic tests, and meshes. CONCLUSION: Robotic system adds a significant overall cost to traditional laparoscopic hernia repair. The cost of the medical and robotic devices and longer operative times are the main factors driving the difference in costs.

1 January 2022 in ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)
Verified
Journal Article
Open access
JMJosé Donizeti de Meira-Júnior
José Donizeti de Meira-Júnior
TCThiago Nogueira Costa
Thiago Nogueira Costa
AMAndre Luis Montagnini
Andre Luis Montagnini
SNSergio Carlos Nahas
Sergio Carlos Nahas
JJJose Jukemura
Jose Jukemura

1 January 2024 in ABCD. Arquivos Brasileiros de Cirurgia Digestiva (São Paulo)
Verified
Journal Article
Open access
PDF file
Francisco TustumiFrancisco Tustumi
Francisco Tustumi
GDGeorge Felipe Bezerra Darce
George Felipe Bezerra Darce
MFMurillo Macedo Lobo Filho
Murillo Macedo Lobo Filho
RARicardo Zugaib Abdalla
Ricardo Zugaib Abdalla
TCThiago Nogueira Costa
Thiago Nogueira Costa
BACKGROUND: One of the primary complications associated with large incisions in abdominal surgery is the increased risk of fascial closure rupture and incisional hernia development. The choice of the fascial closure method and closing with minimal tension and trauma is crucial for optimal results, emphasizing the importance of uniform pressure along the suture line to withstand intra-abdominal pressure. AIMS: To evaluate the resistance to pressure and tension of stapled and sutured hand-sewn fascial closure in the abdominal wall. METHODS: Nine abdominal wall flaps from human cadavers and 12 pigs were used for the experimentation. An abdominal defect was induced after the resection of the abdominal wall and the creation of a flap in the cadaveric model and after performing a midline incision in the porcine models. The models were randomized into three groups. Group 1 was treated with a one-layer hand-sewn small bite suture, Group 2 was treated with a two-layer hand-sewn small bite suture, and Group 3 was treated with a two-layer stapled closure. Tension measurements were assessed in cadaveric models, and intra-abdominal pressure was measured in porcine models. RESULTS: In the human cadaveric model, the median threshold for fascial rupture was 300N (300-350) in Group 1, 400N (350-500) in Group 2, and 350N (300-380) in Group 3. Statistical comparisons revealed non-significant differences between Group 1 and Group 2 (p=0.072, p>0.05), Group 1 and Group 3 (p=0.346, p>0.05), and Group 2 and Group 3 (p=0.184, p>0.05). For porcine subjects, Group 1 showed a median pressure of 80 mmHg (85-105), Group 2 had a median of 92.5 mmHg (65-95), and Group 3 had a median of 102.5 mmHg (80-135). Statistical comparisons indicated non-significant differences between Group 1 and Group 2 (p=0.243, p>0.05), Group 1 and Group 3 (p=0.468, p>0.05), and Group 2 and Group 3 (p=0.083, p>0.05). CONCLUSIONS: Stapled and conventional suturing resist similar pressure and tension thresholds.

1 June 2021 in Videoscopy™
Verified
Journal Article
Closed access
ACAlessandro Carrara
Alessandro Carrara
TCThiago Nogueira Costa
Thiago Nogueira Costa
FNFrancesca Laura Nava
Francesca Laura Nava
LFLuca Fabris
Luca Fabris
MZMichele Zuolo
Michele Zuolo
GTGiuseppe Tirone
Giuseppe Tirone
Introduction: Laparoscopic repair for incisional hernias was described initially in the early 1990s.1 The procedure involves an intraperitoneal mesh placement to achieve a tension-free repair of the hernia. However, in recent years, there has been great concern about long-term complications related to the intraperitoneal mesh placement. Many case reports and case series have found evidence of mesh adhesion, bowel fistulae, shrinking, and migration resulting in various minor and major acute abdominal complications.2 After these concerns, in the past years, many new techniques have been developed, alongside the most traditional ones, such as Rives Stoppa.3,4 These new procedures such as the MILOS, the ELAR, the TESAR, and the REPA5–8 aim to treat incisional hernias in an extraperitoneal way. Our group has recently published a new and innovative technique, the THT (named from our regional surgical group, the Trentino Hernia Team), which aims to reconstruct the abdominal wall midline endoscopically with a linear stapler through a single umbilical access.9 The advantages of this procedure consist mainly in its simplicity of execution and speed (1 hour), its high reproducibility, the extraperitoneal approach (with the only exception of a 5 mm trocar), and the sublay mesh positioning with a significant decrease in costs compared with the traditional Intraperitoneal Onlay Mesh approach.10 Patient Selection and Work-Up: The patient depicted in the video was urgently admitted to our department for strangulation of a voluminous recurrent incisional umbilical hernia. The patient was 53 years old, with a body mass index of 33. He had undergone previous laparoscopic cholecystectomy in 2016 for cholelithiasis and a direct suture of an umbilical trocar site incisional hernia in 2017. At admission, a CT scan revealed a defect of 6 × 8 cm (M3 L6 W2 according to European Hernia Society classification)11,12 with a synchronous epigastric hernia of 2 cm and a diastasis of 8 cm width and 18 cm of longitudinal extension. Informed consent was obtained and he was furthermore informed about the THT procedure and the possibility of a transversus abdominis release (TAR) procedure in case of excessive tension along the median suture. Preoperative Preparation: The surgery was conducted under general anesthesia. A single dose of a short-term antibiotic (cefazolin 2 g i.v.)13 was administered before the operation. Equipment Preference Card: The patient was positioned on the operating table with the right arm open, the left one closed, and split legs. The first operator stood between his legs, the second operator on the patient's left side, and the nurse between the surgeons. Two monitors were used, one positioned behind the right shoulder of the patient, the second one behind his right leg. Methods: First, through a 4 cm periumbilical incision, the umbilicus was disconnected from the fascial plane. The voluminous hernia sac was dissected and opened to verify its content. A portion of necrotic strangulated omentum was resected with Ligasure™ (Medtronic). No ischemic intestinal portions were found inside the hernia. The hernia sac was subsequently resected and the peritoneum closed with an interrupted suture. A Veress needle was positioned through the suture to inflate a pneumoperitoneum of 12 mm Hg. One 10 mm trocar was placed in the patient's left side to have a direct visual check of the peritoneal cavity and the viability of the hernia sac contents. The rectus sheaths were isolated and incised to enter the retromuscular space on both sides. The two branches of a linear stapler were inserted into the two rectus sheaths; because of the patient's tissues thickness (in particular, the posterior rectus sheets), 4.0–5.0 mm linear stapler (EndoGIA™ 60 mm black reload with Tri-Staple™ technology; Medtronic) was used. Two EndoGIA reloads were used to suture the two rectus sheaths first toward the sternum and then toward the pubis, to create a wide retromuscular space. A single-port device (GelPOINT® mini; Applied Medical) was then introduced through the umbilical incision inside the neo-formed retromuscular space. The retromuscular space was then dissected on both sides using a monopolar hook until reaching the costal margins cranially, the arcuate line caudally, and the rectus neurovascular bundles laterally. Three other reloads of EndoGIA 60 mm were used to endoscopically complete the suture of the rectus sheaths from the xiphoid to the Retzius space. Because of the presence of high tension on the midline suture and to the high risk of recurrence associated with the patient's obesity, it was decided to perform a totally endoscopic TAR as an adjunct to the THT technique. Starting from a distance of 5 mm from the origin of the neurovascular peduncles, the posterior rectus sheaths were incised preserving the peritoneum and, as much as possible, the transversalis fascia. The incision was extended to the arcuate line caudally and the costal margin cranially. The transversus muscles were dissected with a high-energy device (Ligasure) creating a wide space between the transverse muscle and the transversalis fascia where the mesh was positioned. At this point, 8 cm per side were gained, allowing a reduction of the tension along the midline. After the measurement of length and width (30 × 27 cm) of the neo-formed retromuscular plane, a macroporous light-weight mesh (Softmesh, Bard) was tailored and positioned endoscopically through the umbilical access. After the removal of the GelPOINT Mini, the two rectus abdominis were joined together using absorbable stitches. The same stitches were also used to transversally suture the margins of the anterior rectus sheaths. A polydioxanone suture was used to reattach the umbilicus to the fascial plane. The cutaneous wounds were closed with intradermal stitches and cyanoacrylate. Results: In the first postoperative 24 hours, the analgesic therapy was set as follows: paracetamol 1 g i.v. every 8 hours, ketoprofen 160 mg i.v. as rescue. The patient was discharged on postoperative day (POD) 2. Antithrombotic prophylaxis (low-weight heparin 4000 UI every 24 hours) was continued for 12 days after. At the follow-up visit on POD 7, a superficial infection (SSI) on the umbilical incision was diagnosed. The infection was limited at the subcutaneous layer on the left margin of the wound. Fifteen days later, the wound appeared to be fully recovered. After 3 months, neither major nor minor complications had been reported. Follow-up at 18 months is free from recurrences. Conclusions: The THT technique associated with TAR represents a feasible and effective treatment for incisional hernias. At present, this technique has been used in eight cases with a short length of hospital stay (2 days) and a fast return to normal activities of daily living (2–4 weeks) along with an excellent quality of life. Except for the SSI of this patient, no other major or minor complications have been reported. In a mean follow-up of 12 months, no recurrences were reported. Nevertheless, more studies are necessary to confirm these preliminary results. No competing financial interests exist. Runtime of video: 10 mins

1 September 2017 in Pancreatology
Verified
Journal Article
Closed access
Francisco TustumiFrancisco Tustumi
Francisco Tustumi
TCThiago Nogueira Costa
Thiago Nogueira Costa
SPSonia Penteado
Sonia Penteado
EFEstela Regina Ramos Regina Ramos Figueira
Estela Regina Ramos Regina Ramos Figueira
TBTelesforo Bacchella
Telesforo Bacchella
ICIvan Cecconello
Ivan Cecconello

1 April 2015 in Hernia
Verified
Journal Article
Closed access
PDF file
JHJ. Harlaar
J. Harlaar
EDE. B. Deerenberg
E. B. Deerenberg
RDRoy S. Dwarkasing
Roy S. Dwarkasing
AKAstrid Kamperman
Astrid Kamperman
JJJ. Jeekel
J. Jeekel
FAF. Abbonante
F. Abbonante