Valdir Fernandes de Aranda

Valdir Fernandes de Aranda

Auto-generated profile, based on publicly available information

Valdir Fernandes de Aranda

Hospital Israelita Albert Einstein São Paulo SP Brazil Hospital Israelita Albert Einstein, São Paulo, SP, Brazil

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Brazilian Journal of Medical and Biological Research
Verified
Journal Article
Open access
PDF file
VAV.F. de Aranda
V.F. de Aranda
PDP.B.M. Derogis
P.B.M. Derogis
LSL.R. Sanches
L.R. Sanches
CMC.L.P. Mangueira
C.L.P. Mangueira
MKM. Katz
M. Katz
JGJ.C. de Campos Guerra
J.C. de Campos Guerra
The aim of the study was to evaluate the diagnostic accuracy of thromboelastometry for assessing rivaroxaban concentrations. The accuracy of thromboelastometry was compared with the high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method, which is the gold standard for drug plasma monitoring (the reference standard). Forty-six clinically stable patients were treated with 10, 15, or 20 mg of rivaroxaban once daily (OD group) or 15 mg twice a day (BID group) (no particular indication for treatment). Patient samples were collected 2 h after the use of the medication (peak) and 2 h before the next dose (trough). The rivaroxaban plasma concentrations were determined via HPLC-MS/MS, and thromboelastometry was performed using a ROTEM® delta analyzer. There were significant prolongations in clotting time (CT) for the 10, 15, and 20 mg of rivaroxaban treatments in the OD groups. In the 15 mg BID group, the responses at the peak and trough times were similar. At the peak times, there was a positive correlation between the plasma concentration of rivaroxaban and CT (Spearman correlation rho=0.788, P<0.001) and clot formation time (rho=0.784, P<0.001), and a negative correlation for alpha angle (rho=−0.771, P<0.001), amplitude after 5 min (rho=−0.763, P<0.001), and amplitude after 10 min (rho=−0.680, P<0.001). The CT presented higher specificity and sensitivity using the cut-off determined by the receiver characteristics curve. ROTEM has potential as screening tool to measure possible bleeding risk associated with rivaroxaban plasma levels.

30 August 2023 in Einstein (São Paulo)
Verified
Journal Article
Open access
PDF file
BSBruno Caldin Silva
Bruno Caldin Silva
RCRicardo Luiz Cordioli
Ricardo Luiz Cordioli
BSBento Fortunato Cardoso dos Santos
Bento Fortunato Cardoso dos Santos
JGJoão Carlos de Campos Guerra
João Carlos de Campos Guerra
RRRoseny dos Reis Rodrigues
Roseny dos Reis Rodrigues
TCThiago Domingos Corrêa
Thiago Domingos Corrêa
Highlights 43.4% of the cohort developed acute kidney injury. D-dimer and fibrinogen levels were high in both groups. Rotational thromboelastometry data were similar between groups. Serum levels of antithrombin activity and protein C were lower in patients who developed acute kidney injury. Objective The incidence of thrombotic events and acute kidney injury is high in critically ill patients with COVID-19. We aimed to evaluate and compare the coagulation profiles of patients with COVID-19 developing acute kidney injury versus those who