Objective: The aim of this study was to evaluate reader variability in screening mammograms according to the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) assessment and breast density categories. Methods: A stratified random sample of 100 mammograms was selected from a population-based breast cancer screening programme in Barcelona, Spain: 13 histopathologically confirmed breast cancers and 51 with true-negative and 36 with false-positive results. 21 expert radiologists from radiological units of breast cancer screening programmes in Catalonia, Spain, reviewed the mammography images twice within a 6-month interval. The readers described each mammography using BI-RADS assessment and breast density categories. Inter- and intraradiologist agreement was assessed using percentage of concordance and the kappa (κ) statistic. Results: Fair interobserver agreement was observed for the BI-RADS assessment [κ=0.37, 95% confidence interval (CI) 0.36–0.38]. When the categories were collapsed in terms of whether additional evaluation was required (Categories III, 0, IV, V) or not (I and II), moderate agreement was found (κ=0.53, 95% CI 0.52–0.54). Intra-observer agreement for BI-RADS assessment was moderate using all categories (κ=0.53, 95% CI 0.50–0.55) and substantial on recall (κ=0.66, 95% CI 0.63–0.70). Regarding breast density, inter- and intraradiologist agreement was substantial (κ=0.73, 95% CI 0.72–0.74 and κ=0.69, 95% CI 0.68–0.70, respectively). Conclusion: We observed a substantial intra-observer agreement in the BI-RADS assessment but only moderate interobserver agreement. Both inter- and intra-observer agreement in mammographic interpretation of breast density was substantial. Advances in knowledge: Educational efforts should be made to decrease radiologists' variability in BI-RADS assessment interpretation in population-based breast screening programmes.
Colorectal cancer (CRC) survival depends mostly on stage at the time of diagnosis. However, symptom duration at diagnosis or treatment have also been considered as predictors of stage and survival. This study was designed to: 1) establish the distinct time-symptom duration intervals; 2) identify factors associated with symptom duration until diagnosis and treatment. This is a cross-sectional study of all incident cases of symptomatic CRC during 2006–2009 (795 incident cases) in 5 Spanish regions. Data were obtained from patients’ interviews and reviews of primary care and hospital clinical records. Measurements: CRC symptoms, symptom perception, trust in the general practitioner (GP), primary care and hospital examinations/visits before diagnosis, type of referral and tumor characteristics at diagnosis. Symptom Diagnosis Interval (SDI) was calculated as time from first CRC symptoms to date of diagnosis. Symptom Treatment Interval (STI) was defined as time from first CRC symptoms until start of treatment. Nonparametric tests were used to compare SDI and STI according to different variables. Symptom to diagnosis interval for CRC was 128 days and symptom treatment interval was 155. No statistically significant differences were observed between colon and rectum cancers. Women experienced longer intervals than men. Symptom presentation such as vomiting or abdominal pain and the presence of obstruction led to shorter diagnostic or treatment intervals. Time elapsed was also shorter in those patients that perceived their first symptom/s as serious, disclosed it to their acquaintances, contacted emergencies services or had trust in their GPs. Primary care and hospital doctor examinations and investigations appeared to be related to time elapsed to diagnosis or treatment. Results show that gender, symptom perception and help-seeking behaviour are the main patient factors related to interval duration. Health service performance also has a very important role in symptom to diagnosis and treatment interval. If time to diagnosis is to be reduced, interventions and guidelines must be developed to ensure appropriate examination and diagnosis during both primary and hospital care.
13 March 2006 in Journal of Epidemiology and Community Health
Study objective: To investigate the cumulative false positive recall rate throughout the period of participation in a population based breast cancer screening programme and to examine its association with women related factors. Design: Analysis of a database to estimate the cumulative false positive recall rate after 10 biennial mammograms in a cohort of women. Cumulative risk after 10 rounds was calculated by projecting forward the information available on the four rounds. Logistic regression was used to evaluate the association between the cumulative risk of false positive recall and women related factors. Setting: Population based breast cancer screening programme in Barcelona City (Spain). Participants: 8502 women aged 50–69 years who participated in four consecutive screening rounds. Eligible women had received a mammogram in the first screening round between 1 December 1995 and 31 December 1996. Main results: The false positive recall rate in the first screening for women who entered the screening programme at the age of 50–51 years was assessed at 10.6% (95% CI 8.9, 12.3). In the second screening this risk decreased to 3.8% (95% CI 2.7, 4.9) and remained almost constant in subsequent rounds. After 10 mammograms, the cumulative false positive recall rate was estimated at 32.4% (95% CI 29.7, 35.1). The factors associated with a higher cumulative risk of false positive recall were: previous benign breast disease (OR = 8.48; CI 7.39, 9.73), perimenopausal status (OR = 1.62; CI 1.12, 2.34), body mass index above 27.3 (OR = 1.17; CI 1.02, 1.34), and age 50–54 years (OR = 1.15; CI 1.00, 1.31). Conclusions: One third of women could have at least one false positive recall over 10 biennial screens. Women participating in screening programmes should be informed about this risk, especially those with associated factors.