22 April 2009 in Materialwissenschaft und Werkstofftechnik
7 September 2019 in Metrology and instruments
Investigating pulse in different parts of the body is of great interest to doctors. The purpose is the development of metrological maintenance, calibration and certification of photometric instruments [1—3]. Photoplethysmograph is designed to record changes in optical density of a person’s body area with a beam of light reflected in the light [4—6]. Measurements are carried out non-invasively [7]. Such device registers pulse wave (PW) signals and reference ECG with computer processing, Fig. 1—2 [8—10]. A working measure (LED) was created and calibrated using an optical radiation power meter based on the substitution method [11], test bench is at Fig. 3, calibration results — in Table 1 and Fig. 4. Test bench for device calibration and an optical radiator are at Fig. 5—6, view of calibrated signal — at Fig. 7. As a result of calibration (Table 2) the dependence of the output signal on LED power supply (Fig. 8) is obtained, and the calibration dependence is shown at Fig. 9. In the test bench for SMC used standardized light filters KNS-01 at a wavelength of 630 nm (Fig. 10a). The calibration curve is calculated as the dependence of the relative coefficient of inverse light dispersion (RCILD) on PW (Fig. 10b, Table 3). The view of output signal is at Fig. 11. As a result of SMC, the limits of permissible absolute error of 2 % in the range of RCILD (15—100) % are defined.
1 January 2010 in IFMBE Proceedings
OZOleksandr V. Zakorcheny
+2
29 November 2022 in Cybernetics and Computer Technologies
Introduction. The article is devoted to the calibration and graduation of the multi-sensor gas analyzer developed at the V.M. Glushkov Institute of Cybernetics of National Academy of Sciences of Ukraine. The modern trend in the development of medical equipment, in particular, containing built-in measuring devices, consists in its miniaturization, intellectualization, the use of information technologies, and the introduction of wireless and network means of data transmission. The purpose of the article is to design, create electronics and software for recording the concentration of three gases (oxygen, carbon dioxide and carbon monoxide), test and calibrate the device. Results. Three prototypes of sensor modules for oxygen, carbon dioxide and carbon monoxide have been created. The structure, scheme of connection of sensor modules, and the principle of operation of the gas analyzer was described. Testing and optimization of these prototypes were performed. Auxiliary pneumatic equipment for checking the performance of devices, their calibration and graduation was manufactured. Measurement technique was developed and test measurements of the specified gases were performed. The calibration technique was developed and the device was calibrated using two test gas samples such as ethanol vapor and air-gas mixture of carbon dioxide. In addition, a special software has been developed, which allow observe a registered input signal from sensor modules and store it to the file. Conclusions. As a result of the work, prototype of the device was created, its testing, calibration and graduation were carried out at the State Enterprise "Ukrmetrteststandart", 4 certificates of metrological attestation were obtained. The gas analyzer can be used for screening of healthy persons based on study of exhalation to predict the risk of diseases.