Huijie Xu

Huijie Xu

Auto-generated profile, based on publicly available information

Huijie Xu

Department of Otolaryngology, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, China Academy of Medicine Sciences, Beijing, P.R. China

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 March 2017 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
HPHao Peng
Hao Peng
HXHuijie Xu
Huijie Xu
ZXZhiyong Xu
Zhiyong Xu
WHWeining Huang
Weining Huang
RJRuifang Jia
Ruifang Jia
WHWeihong Huang
Weihong Huang
Objective: To discuss the possibility of fundamental frequency (F0) and formant frequency (FF) to generally differentiate the sources of snoring sounds determined by drug-induced sleep endoscopy (DISE). Methods: A total of 74 snoring subjects underwent DISE and snoring sounds were recorded simultaneously. The noise-suppressed snoring sounds were analyzed and classified into different groups based on the sources of vibration identified by DISE. F0 and FFs were calculated. Results: Totally, 516 snoring sounds from three vibrating sources (the palate, combined the palate and the lateral wall, the lateral wall) of 47 patients were divided into three groups then analyzed. The levels of F0 and FFs for each group follow the order: Group 1 < Group 2 < Group 3. There was statistical difference between Group 1 and other groups in F0 and F2 (p < .05). The area under the receiver–operator curves (AUC) was F0, at 0.727, and the cut-off value was 134.2 Hz; and F2, at 0.654, and the cut-off value was 2028.0 Hz. Conclusions: F0 and the second formant frequency (F2) are found to be significantly lower in palatal snoring sound. F0 might be a significant in distinguishing palatal snoring sound from non-palatal snoring sound. F2 is more significant than F1 and F3 in identifying the sources of the snoring sounds but is less sensitive than F0.

26 March 2015 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
PDF file
HPHao Peng
Hao Peng
HXHuijie Xu
Huijie Xu
ZGZhan Gao
Zhan Gao
WHWeining Huang
Weining Huang
YHYuxia He
Yuxia He
Conclusion: The sound pressure level (SPL) parameters, especially the A-weighted equivalent sound level (LAeq) and accumulative percentile sound level 10 (L10), were significantly different between simple snoring (SS) and obstructive sleep apnea-hypopnea syndrome (OSAHS). The apnea-hypopnea index (AHI) was the most significant factor to affect the SPLs of snoring sounds. LAeq and L10 were valuable acoustic characters of snoring which could reflect the severity of sleep disordered breathing in clinic. Objectives: Due to the limitation of acoustic analysis of single snoring sound for snorers, this study analyzed characteristics of consecutive snoring sounds overnight by the SPLs in patients of SS and OSAHS. Method: Ninety-four patients who underwent simultaneous SPL recording and polysomnography (PSG) were included in this study. Parameters of SPL such as LAeq, peak sound level (Lpeak), L10, L50, and L90 were analyzed. The correlation between these parameters and PSG results was also analyzed. Results: The LAeq and L10 in OSAHS patients were significantly different from patients with SS. The body mass index (BMI) was positively correlated to LAeq and L10. Among various factors of PSG data and demographic factors, the SPLs were mostly affected by the AHI and the lowest oxygen saturation (LSaO2).

11 September 2014 in Interdisciplinary Sciences: Computational Life Sciences
Verified
Journal Article
Closed access
PDF file
KQKun Qian
Kun Qian
JGJian Guo
Jian Guo
HXHuijie Xu
Huijie Xu
ZZZhaomeng Zhu
Zhaomeng Zhu
GZGongxuan Zhang
Gongxuan Zhang

25 September 2017 in Interdisciplinary Sciences: Computational Life Sciences
Verified
Journal Article
Closed access
PDF file
JGJian Guo
Jian Guo
KQKun Qian
Kun Qian
GZgongxuan zhang
gongxuan zhang
HXHuijie Xu
Huijie Xu
BSBjörn Schuller
Björn Schuller

1 January 2023 in Journal of Clinical Sleep Medicine
Verified
Journal Article
Closed access
HPHao Peng
Hao Peng
HXHuijie Xu
Huijie Xu
ZXZhiyong Xu
Zhiyong Xu
RJRuifang Jia
Ruifang Jia
HYHui Yu
Hui Yu
The goal of this study was to investigate the value of the long-term average spectrum in the acoustic analysis of snore sounds arising from different sources in the upper airway. Long-term average spectrum was used to analyze sequences of 10 consecutive snore sounds that had been divided into 2 groups, soft-palate type and lateral-wall type, according to the vibration site generating the snore sounds and the patterns of soft tissue collapse in the upper airway as identified by drug-induced sleep endoscopy. We calculated the first spectral peak, mean spectral energy, high-frequency energy, 0-1 kHz spectral energy, 1-5 kHz spectral energy, and 0-1 kHz/1-5 kHz difference from each group and compared the differences between them. All parameters except mean spectral energy showed significant differences between the 2 groups. The first spectral peak of less than 265.53 Hz, and the 0-1k/1-5 kHz difference of less than -11.6 dB strongly suggests soft-palate-type snore sounds. Long-term average spectrum has potential application for snore sound source identification. We recommend using first spectral peak and a 0-1 kHz/1-5 Hz difference to identify soft-palate-type snore sounds. Peng H, Xu H, Xu Z, Jia R, Yu H. Long-term average spectrum measures of consecutive snore sounds from different sources determined by drug-induced sleep endoscopy. J Clin Sleep Med. 2023;19(1):145-150.