We have introduced an approach for low optical absorption coefficient measurement of piezoelectric materials based on the piezoelectric resonance laser calorimetry (PRLC) method. An RF oscillator circuit provides a convenient way to track the piezoelectric resonance frequency during laser irradiation. In this work, the optical absorption coefficient of lithium triborate crystal under high-power IR laser irradiation was measured using the oscillator circuit and the conventional PRLC technique.
Phase-matching temperature tuning curves and longitudinal temperature distribution of periodically poled lithium niobate (PPLN) crystal were measured in the process of second-harmonic generation (SHG) of 1070 nm pump wavelength using tiny transparent piezoelectric crystals as the temperature sensors. The temperatures of the crystal sensors placed along the PPLN length were determined directly by measuring the induced frequency shifts of their piezoelectric resonances, which were excited in a noncontact manner by a probe radio-frequency electric field. Such temperature sensors do not suffer additional heating conditioned by absorption of scattered radiation and also do not have any contact wires. Due to the high factors of piezoelectric resonances, the measurement accuracy of 0.05°C was achieved for a local determination of PPLN surface temperature during SHG. The self-consistent theoretical model that describes the SHG process in the presence of induced nonuniform temperature distribution of the nonlinear-optical crystal is introduced.
A novel method of acoustic resonance laser calorimetry (ARLC) for the determination of low optical absorption coefficients of crystals and glasses is introduced. It is based on measurements of the kinetics of the equivalent temperature of the sample irradiated by the pulse laser radiation. The equivalent temperature of the sample is directly obtained by measuring the frequency changes of its temperature-calibrated acoustic resonances excited by the laser radiation with a corresponding pulse repetition rate. In contrast to the conventional resonant photoacoustic spectroscopy, where the resonance is used for the enhancement of the registered signal, in ARLC, the laser-excited acoustic resonance of the sample acts as a high-sensitivity temperature probe for measurements of its heating kinetics. The ARLC approach was verified by measuring the optical absorption coefficient of the potassium dihydrogen phosphate crystal ( ) at 1064 nm wavelength.
We introduce the experimental and theoretical investigation of the mutual influence of two four-wave mixing (FWM) processes during the propagation of high-power nanosecond pulses at 1030 nm and 1562 nm wavelengths in the few-mode optical fiber. Both fundamental mode FWM (FM FWM) of laser pulses at these wavelengths, and intermodal FWM (IM FWM) of 1030 nm pulses, have common anti-Stokes components at 1003 nm wavelength. This leads to the mutual influence of FWM effects. As a result, the decrease of optical power of the fundamental mode is observed at both 1030 nm and 1562 nm wavelengths. The method for the suppression of such an adverse effect is proposed. It is based on the attenuation of the 1030 nm higher LP11 mode at the few-mode optical fiber input.
We introduce an approach for the temperature stabilization of nonlinear-optic crystals during laser frequency conversion processes. This approach is based on the stabilization of the piezoelectric resonance (PR) frequency of the crystal, so that the crystal itself becomes a temperature sensor. Application of an electronic oscillator provides a remarkably handy way to determine the PR frequency. When the PR frequency stabilization was employed, the stable generation of the second harmonic (SH) at 532 nm wavelength was achieved in periodically poled lithium niobate (PPLN) at more than 30% power compared to the case of the application of external temperature sensors. Long-term stability of SH power was also enhanced.
A spatial diagnostic of optical quality of the massive lithium triborate crystal boule with untreated facets was performed by measuring optical absorption coefficients at 1070 and 1908 nm wavelengths using the piezoelectric resonance laser calorimetry technique.