Javad Safaie

Javad Safaie

Auto-generated profile, based on publicly available information

Javad Safaie

Electrical Engineering Department, Faculty of Engineering, Ferdowsi University of Mashhad, Mashhad, Iran

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2013 in Journal of Neural Engineering
Verified
Journal Article
Closed access
PDF file
JSJ Safaie
J Safaie
RGR Grebe
R Grebe
HMH Abrishami Moghaddam
H Abrishami Moghaddam
FWF Wallois
F Wallois
Objective. Interactions between neuronal electrical activity and regional changes in microcirculation are assumed to play a major role in physiological brain activity and the development of pathological disorders, but have been poorly elucidated to date. There is a need for advanced diagnostic tools to investigate the relationships between these two physiological processes.Approach. To meet these needs, a wireless wearable system has been developed, which combines a near infrared spectroscopy (NIRS) system using light emitting diodes (LEDs) as a light source and silicon photodiodes as a detector with an integrated electroencephalography (EEG) system. Main results. The main advantages over currently available devices are miniaturization and integration of a real-time electrical and hemodynamic activity monitor into one wearable device. For patient distributed monitoring and creating a body-area network, up to seven same devices can be connected to a single base station (PC) synchronously. Each node presents enhanced portability due to the wireless communication and highly integrated components resulting in a small, lightweight signal acquisition device. Further progress includes the individual control of LEDs output to automatically or interactively adjust emitted light to the actual local situation online, the use of silicon photodiodes with a safe low-voltage power supply, and an integrated three dimensional accelerometer for movement detection for the identification of motion artifacts. Significance. The device was tested and validated using our enhanced EEG-NIRS tissue mimicking fluid phantom for sensitivity mapping. Typical somatotopic electrical evoked potential experiments were performed to verify clinical applicability.

9 May 2011 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
APAmol V. Patil
Amol V. Patil
JSJavad Safaie
Javad Safaie
HMHamid Abrishami Moghaddam
Hamid Abrishami Moghaddam
FWFabrice Wallois
Fabrice Wallois
RGReinhard Grebe
Reinhard Grebe
Near infrared spectroscopy (NIRS) is regarded as a potential medical diagnostic technique for investigation of hemodynamic changes. However, uncertainties pertaining to the origin of NIRS signals have hampered its clinical interpretation. The uncertainities in NIRS measurements especially in case of living tissues are due to lack of rigorous combined theoretical-experimental studies resulting in clear understanding of the origin of NIRS signals. For their reliable interpretation it is important to understand the relationship between spatial changes in optical properties and corresponding changes in the NIRS signal. We investigated spatial sensitivity of near infrared optical measurements using an experimental approach. It uses a liquid optical phantom as tissue equivalent, which is explored under robot-control by a small, approximately point like perturbation of desired optical properties, and a NIRS instrument for trans-illumination/reflection measurements. The experimentally obtained sensitivity has been analyzed and compared with numerical simulations. In preliminary experiments we investigated the influence of various optical properties of the medium and of source/detector distances on the spatial sensitivity distribution. The acquired sensitivity maps can be used to define characteristic parameters. As an example, we used a 25% threshold to define a penetration depth measure which provides values in good accordance with published ones. To the best of our knowledge this is the first experimental study of NIRS spatial sensitivity. The presented method will allow in depth experimental investigation of the influence of various conditions pertaining to medium such as optical properties of tissue (scattering and absorption) and of the source/detector configuration.

10 June 2020 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
SMSohrab Milanizadeh
Sohrab Milanizadeh
JSJavad Safaie
Javad Safaie
Human Computer Interface systems are extending their boundaries in our daily life and become an important subject in biomedical engineering. Electrooculogram signal as an input for such systems stems from the corneo-retinal standing potential, which can be used for monitoring human eye rotation. Higher amplitude, better signal-to-noise ratio, and much easier recording conditions compared to EEG, make it an important input modality for HCI systems. In the present study, a real-time processing and cost effective (<100$) HCI system was designed and developed based on the EOG signals. The required electrodes were embedded in updated eyeglasses for easy electrode placement over the subject s face. EOG signals were acquired by the subject’s eye movement toward the four middle parts of screen edges of a laptop placed in front of them. The system training for each subject ameliorated system withstanding against the blink and wrinkle artifact. Finally, the required commands for quadcopter navigation (up, down, left and right) generated with 0.6s total delay and 94.8% of system accuracy in detecting the correct eye movements. A real quadcopter navigation experiment based on the standard navigation interface and the developed HCI system represented the system accuracy, robustness and usefulness.

3 January 2018 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
MAMahdi Abbasi
Mahdi Abbasi
AAAref Afsharfard
Aref Afsharfard
RARoya Arasteh
Roya Arasteh
JSJavad Safaie
Javad Safaie

6 April 2020 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ZQZahra Qaviandam
Zahra Qaviandam
NNNadia Naghavi
Nadia Naghavi
JSJavad Safaie
Javad Safaie
This paper presents a new approach to improve the performance of IPMC-based sensors as reliable deflection sensors. Theoretical and experimental responses of an IPMC sensor strip were investigated when it was being biased by an AC electrical signal source. Using an especially-designed experimental setup, the sensitivity, linearity, and stability of the biased sensor were analyzed under different deflection angles. Moreover, the impact of frequency and amplitude of the bias signal, the influence of internal impedance of the bias signal source, and the effect of mechanical deflection frequency and angle on the performance of the IPMC sensor were studied. Theoretical and experimental results indicated that it would be possible to greatly improve the sensitivity (446.5 times) and stability (24.4 times) of an IPMC deflection sensor by applying an appropriate electrical bias signal.

13 December 2025 in Sensors and Actuators A: Physical
Verified
Journal Article
Closed access
MBMahnaz Bayat
Mahnaz Bayat
JSJavad Safaie
Javad Safaie
SBSahar Mollazadeh Beidokhti
Sahar Mollazadeh Beidokhti
FWFabrice Wallois
Fabrice Wallois