Martin Albrecht

Martin Albrecht

Auto-generated profile, based on publicly available information

Martin Albrecht

The Extreme Light Infrastructure ERIC

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2021 in The European Physical Journal Special Topics
Verified
Journal Article
Open access
PDF file
EKEva Klimešová
Eva Klimešová
OKOlena Kulyk
Olena Kulyk
ZHZiaul Hoque
Ziaul Hoque
ARAndreas Hult Roos
Andreas Hult Roos
KKKrishna P. Khakurel
Krishna P. Khakurel
MJMatej Jurkovič
Matej Jurkovič
We report on the status of a users’ end-station, MAC: a Multipurpose station for Atomic, molecular and optical sciences and Coherent diffractive imaging, designed for studies of structure and dynamics of matter in the femtosecond time-domain. MAC is located in the E1 experimental hall on the high harmonic generation (HHG) beamline of the ELI Beamlines facility. The extreme ultraviolet beam from the HHG beamline can be used at the MAC end-station together with a synchronized pump beam (which will cover the NIR/Vis/UV or THz range) for time-resolved experiments on different samples. Sample delivery systems at the MAC end-station include a molecular beam, a source for pure or doped clusters, ultrathin cylindrical or flat liquid jets, and focused beams of substrate-free nanoparticles produced by an electrospray or a gas dynamic virtual nozzle combined with an aerodynamic lens stack. We further present the available detectors: electron/ion time-of-flight and velocity map imaging spectrometers and an X-ray camera, and discuss future upgrades: a magnetic bottle electron spectrometer, production of doped nanodroplets and the planned developments of beam capabilities at the MAC end-station.

19 February 2020 in Journal of Vacuum Science & Technology B
Verified
Journal Article
Open access
PDF file
Shirly EspinozaShirly Espinoza
Shirly Espinoza
FSFabio Samparisi
Fabio Samparisi
Fabio FrassettoFabio Frassetto
Fabio Frassetto
SRSteffen Richter
Steffen Richter
MRMateusz Rebarz
Mateusz Rebarz
JAJakob Andreasson
Jakob Andreasson
In this paper, the authors present the characterization experiments of a 20 fs vacuum ultraviolet beam from a high harmonic generation source. The beam hits a silicon sample and passes a triple reflection gold polarizer located inside an ultrahigh vacuum chamber. The polarizer’s Malus curve was obtained; the total acquisition time for each point of the curve was 30 s. This aims to be the first vacuum ultraviolet time-resolved user station dedicated to ellipsometry. The high harmonic beam is generated by a 12 mJ, 1 kHz, 20 fs, in-house-developed laser and detected by a back-illuminated charge-coupled device.

1 June 2019 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
JNJ. Nejdl
J. Nejdl
JVJ. Vančura
J. Vančura
KBK. Boháček
K. Boháček
MAM. Albrecht
M. Albrecht
UCUddhab Chaulagain
Uddhab Chaulagain
A new optical probing method with increased interferometric sensitivity for a low-density gas jet characterization is presented. The proposed technique employs a Michelson interferometer with a self-imaging object arm, which enables the relay imaging of the object on itself, and in this way, the phase sensitivity of the device is increased by a double propagation of the object laser beam through the gas jet. The wavelength of 405 nm was chosen to further increase the sensitivity by increasing the probe wavenumber. A low-density argon gas jet with various backing pressures was characterized by our method and by a commonly used Mach-Zehnder interferometer setup showing the expected twofold increase in the signal to noise ratio in the double pass configuration.

5 November 2018 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
VNV. E. Nefedova
V. E. Nefedova
Marcelo CiappinaMarcelo Ciappina
Marcelo Ciappina
OFO. Finke
O. Finke
MAM. Albrecht
M. Albrecht
MKM. Kozlová
M. Kozlová
JNJ. Nejdl
J. Nejdl
The low conversion efficiency of high-order harmonic generation (HHG) in gases is an insurmountable limitation for many applications, where a considerable photon flux is an instrumental prerequisite. We present a study of the HHG conversion efficiency dependence on the driving laser intensity and analyze the conditions for optimal phase-matching in a loose focusing configuration and long generation medium using a Ti:Sapphire laser. Moreover, by determination of the influence of plasma effects on the driving laser pulse, we observe a correlation between the HHG conversion efficiency and the blueshift of the fundamental pulse. The maximal HHG conversion efficiency is achieved just before the driving laser spectrum is considerably affected by the plasma. Similar behavior is observed in HHG for different noble gases. In this respect, the appearance of a plasma-induced spectral shift in the driving laser might serve as an indication of a substantial loss of HHG conversion efficiency. Consequently, our findings can be exploited to obtain essential information about the laser-plasma interaction process during HHG and can pave the way for a more convenient control of optimal HHG conditions.

1 January 2023 in New Journal of Physics
Verified
Journal Article
Open access
ARAndreas H Roos
Andreas H Roos
ZHZiaul Hoque
Ziaul Hoque
EKEva Klimešová
Eva Klimešová
LLLtaief Ben Ltaief
Ltaief Ben Ltaief
CMCristian Medina
Cristian Medina
MKMaria Krikunova
Maria Krikunova
We have investigated the possibility to track and control correlation dynamics of valence electrons in krypton (Kr) initiated by the absorption of one extreme ultraviolet (XUV) photon. In this investigation, pump-probe experiments have been performed where monochromatized single high-harmonics at photon energies 29.6, 32.8, and 35.9 eV have been used as pump to populate different intermediate excited states. A temporally delayed near-infrared (NIR) pulse probes the population of various decay channels via the detection of Kr2+ ion yields and its transient profiles. We observe that by varying the NIR pulse intensity within a range from 0.3 × 10 13 to 2.6 × 10 13 W cm−2, the shape of the Kr2+ transient profile changes significantly. We show that by varying the intensity of the NIR pulse, it is possible—(i) to control the ratio between sequential and non-sequential double ionization of Kr; (ii) to selectively probe quantum beating oscillations between Kr + ∗ satellite states that are coherently excited within the bandwidth of the XUV pulse; and (iii) to specifically probe the relaxation dynamics of doubly excited (Kr ∗ ∗ ) decay channels. Our studies show that the contribution of different ionization and decay channels (i)–(iii) can be altered by the NIR pulse intensity, thus demonstrating an efficient way to control the ionization dynamics in rare gas atoms.

1 November 2021 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
AZAnna Zymaková
Anna Zymaková
MAMartin Albrecht
Martin Albrecht
RARoman Antipenkov
Roman Antipenkov
AŠAlexandr Špaček
Alexandr Špaček
SKStefan Karatodorov
Stefan Karatodorov
JUJens Uhlig
Jens Uhlig
ELI Beamlines is a rapidly progressing pillar of the pan-European Extreme Light Infrastructure (ELI) project focusing on the development and deployment of science driven by high-power lasers for user operations. This work reports the results of a commissioning run of a water-jet plasma X-ray source driven by the L1 Allegra laser, outlining the current capabilities and future potential of the system. The L1 Allegra is one of the lasers developed in-house at ELI Beamlines, designed to be able to reach a pulse energy of 100 mJ at a 1 kHz repetition rate with excellent beam properties. The water-jet plasma X-ray source driven by this laser opens opportunities for new pump–probe experiments with sub-picosecond temporal resolution and inherent synchronization between pump and probe pulses.