Byunghoon Chung

Byunghoon Chung

Auto-generated profile, based on publicly available information

Byunghoon Chung

From the Eyereum Eye Clinic (B.C., J.Y.C., D.S.Y.K., K.Y.K.), Seoul, Republic of Korea

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
BCByunghoon Chung
Byunghoon Chung
HLHun Lee
Hun Lee
CRCynthia J. Roberts
Cynthia J. Roberts
DKDavid Kang
David Kang
DRDan Z. Reinstein
Dan Z. Reinstein
TKTae-im Kim
Tae-im Kim
To assess the agreement of decentration measurements between tangential curvature topography and tomography pachymetry difference maps after a small-incision lenticule extraction (SMILE) procedure. Yonsei University College of Medicine and Eyereum Eye Clinic, Seoul, South Korea. Retrospective case series. Decentrations and pupillary offset (angle κ) were analyzed and compared using two different methods. A difference map of the tangential curvature was generated with a Placido corneal topographer (Keratron Scout) and a pachymetry difference map was generated with a Scheimpflug tomographer (Pentacam) for each eye, using preoperative and 3-month postoperative scans. Decentrations were also compared using a vector difference plot for the two maps. The study comprised 155 eyes (155 patients). The magnitude of decentration was 0.27 mm ± 0.17 (SD) (range 0.02 to 0.88 mm) with the tangential curvature difference maps and 0.26 ± 0.20 mm (range 0.00 to 0.91 mm) with the pachymetry difference maps, showing no significant difference in the arithmetic values of decentration (P = .124). However, the vector difference in pupillary offset between preoperative and postoperative measurements from the pachymetry difference map significantly correlated with the magnitude of vector differences of decentration between the two maps (P = .007). The vector difference plot also showed a wide distribution spread to all 4 quadrants, demonstrating a lack of agreement. Although there was no significant difference between the scalar magnitude of decentration with the tangential topography difference maps and tomography pachymetry difference maps, the vector differences did not agree and increasing error was present with increasing differences in pupillary offset in the pachymetry difference maps.

13 August 2024 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
BCByunghoon Chung
Byunghoon Chung
JCJin Young Choi
Jin Young Choi
DKDavid S.Y. Kang
David S.Y. Kang
KKKangyoon Kim
Kangyoon Kim
BKBo Yi Kim
Bo Yi Kim
TKTae-im Kim
Tae-im Kim

7 March 2015 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
JSJoo Youn Shin
Joo Youn Shin
MCMoonjung Choi
Moonjung Choi
BCByunghoon Chung
Byunghoon Chung
SBSuk Ho Byeon
Suk Ho Byeon

1 June 2015 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
JJJi Won Jung
Ji Won Jung
BCByung Hoon Chung
Byung Hoon Chung
SHSun Hyup Han
Sun Hyup Han
EKEung Kweon Kim
Eung Kweon Kim
Kyoung Yul SeoKyoung Yul Seo
Kyoung Yul Seo
TKTae-im Kim
Tae-im Kim
Original Article Ji Won Jung, MD; Byung Hoon Chung, MD; Sun Hyup Han, BA; Eung Kweon Kim, MD, PhD; Kyoung Yul Seo, MD, PhD; Tae-im Kim, MD, PhD To compare the measurements of refractive errors and ocular aberrations obtained using iDesign and WaveScan (Abbott Medical Optics, Inc., Santa Ana, CA), and to compare surgical outcomes of wavefront-guided LASEK using ablation profiles based on both aberrometers. Ninety myopic eyes of 45 normal patients were evaluated using both the iDesign and WaveScan to measure spherical and cylindrical errors, spherical equivalents, and Zernike coefficients of ocular aberrations. Wavefront-guided LASEK was performed in a different group of 59 eyes of 30 patients divided into two groups, the iDesign and Wavescan groups. The clinical outcomes between the two groups including uncorrected visual acuity, refractive errors, contrast sensitivity, and ocular aberration were compared at 1, 3, and 6 months postoperatively. The iDesign produced significantly higher myopic values for refractive errors than the WaveScan, as well as significantly lower levels of total higher order, third, fourth, and fifth order root mean square values and Zernike coefficients of vertical coma and spherical aberration. At postoperative 1, 3, and 6 months, there were no statistically significant differences between the two groups in terms of uncorrected visual acuity and remaining refractive errors. The percentages of patients with spherical equivalents within ±1.00 and ±0.50 diopters of emmetropia were 100% (29 eyes) and 75.9% (22 eyes), respectively, in the iDesign group and 96.7% (29 eyes) and 70.0% (21 eyes), respectively, in the WaveScan group. Mesopic contrast sensitivity values were significantly higher, and the change in root mean square values for spherical aberration was significantly lower in the iDesign group. There were significant differences between the iDesign and the WaveScan in the measurements of refraction and ocular aberrations. Wavefront-guided LASEK based on an ablation profile from the iDesign demonstrated comparable refractive predictability with the WaveScan group, resulting in minimal physician adjustment and superior postoperative visual quality. [J Refract Surg. 2015;31(6):398–405.] From the Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea (JWJ, BHC, SHH, EKK, KYS, TIK); the Department of Ophthalmology and Inha Vision Science Laboratory, Inha University School of Medicine, Incheon, South Korea (JWJ); and the Corneal Dystrophy Research Institute, Severance Biomedical Science Institute, and Brain Korea 21 Plus Project for Medical Science, Yonsei University College of Medicine, Seoul, South Korea (EKK). The authors have no financial or proprietary interest in the materials presented herein. Supported in part by a grant from the Korean Health Technology R & D Project, Ministry of Health & Welfare, Republic of Korea (HI14C2044) and the Basic Science Research Program through the National Research Foundation of Korea funded by the Ministry of Education, Science, and Technology (2013R1A1A2058907). AUTHOR CONTRIBUTIONS Study concept and design (JWJ, TIK); data collection (JWJ, BHC); analysis and interpretation of data (JWJ, EKK, KYS, TIK); writing the manuscript (JWJ, TIK); critical revision of the manuscript (JWJ, EKK, KYS, TIK); statistical expertise (JWJ); administrative, technical, or material support (SHH); supervision (TIK) Correspondence: Tae-im Kim, MD, PhD, Department of Ophthalmology, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, South Korea, 120-752. E-mail: tikim@yuhs.ac To compare the measurements of refractive errors and ocular aberrations obtained using iDesign and WaveScan (Abbott Medical Optics, Inc., Santa Ana, CA), and to compare surgical outcomes of wavefront-guided LASEK using ablation profiles based on both aberrometers. Ninety myopic eyes of 45 normal patients were evaluated using both the iDesign and WaveScan to measure spherical and cylindrical errors, spherical equivalents, and Zernike coefficients of ocular aberrations. Wavefront-guided LASEK was performed in a different group of 59 eyes of 30 patients divided into two groups, the iDesign and Wavescan groups. The clinical outcomes between the two groups including uncorrected visual acuity, refractive errors, contrast sensitivity, and ocular aberration were compared at 1, 3, and 6 months postoperatively. The iDesign produced significantly higher myopic values for refractive errors than the WaveScan, as well as significantly lower levels of total higher order, third, fourth, and fifth order root mean square values and Zernike coefficients of vertical coma and spherical aberration. At postoperative 1, 3, and 6 months, there were no statistically significant differences between the two groups in terms of uncorrected visual acuity and remaining refractive errors. The percentages of patients with spherical equivalents within ±1.00 and ±0.50 diopters of emmetropia were 100% (29 eyes) and 75.9% (22 eyes), respectively, in the iDesign group and 96.7% (29 eyes) and 70.0% (21 eyes), respectively, in the WaveScan group. Mesopic contrast sensitivity values were significantly higher, and the change in root mean square values for spherical aberration was significantly lower in the iDesign group. There were significant differences between the iDesign and the WaveScan in the measurements of refraction and ocular aberrations. Wavefront-guided LASEK based on an ablation profile from the iDesign demonstrated comparable refractive predictability with the WaveScan group, resulting in minimal physician adjustment and superior postoperative visual quality. [J Refract Surg. 2015;31(6):398–405.] From the Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea (JWJ, BHC, SHH, EKK, KYS, TIK); the Department of Ophthalmology and Inha Vision Science Laboratory, Inha University School of Medicine, Incheon, South Korea (JWJ); and the Corneal Dystrophy Research Institute, Severance Biomedical Science Institute, and Brain Korea 21 Plus Project for Medical Science, Yonsei University College of Medicine, Seoul, South Korea (EKK). The authors have no financial or proprietary interest in the materials presented herein. Supported in part by a grant from the Korean Health Technology R & D Project, Ministry of Health & Welfare, Republic of Korea (HI14C2044) and the Basic Science Research Program through the National Research Foundation of Korea funded by the Ministry of Education, Science, and Technology (2013R1A1A2058907). AUTHOR CONTRIBUTIONS Study concept and design (JWJ, TIK); data collection (JWJ, BHC); analysis and interpretation of data (JWJ, EKK, KYS, TIK); writing the manuscript (JWJ, TIK); critical revision of the manuscript (JWJ, EKK, KYS, TIK); statistical expertise (JWJ); administrative, technical, or material support (SHH); supervision (TIK) Correspondence: Tae-im Kim, MD, PhD, Department of Ophthalmology, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, South Korea, 120-752. E-mail: tikim@yuhs.ac 10.3928/1081597X-20150521-06

1 February 2016 in Optometry and Vision Science
Verified
Journal Article
Closed access
JSJoo Youn Shin
Joo Youn Shin
HCHun Jin Choi
Hun Jin Choi
BCByunghoon Chung
Byunghoon Chung
MCMoonjung Choi
Moonjung Choi
JLJonghyun Lee
Jonghyun Lee
SBSuk Ho Byeon
Suk Ho Byeon