18 July 2012 in Behavior Research Methods
Ternary eye movement classification, which separates fixations, saccades, and smooth pursuit from the raw eye positional data, is extremely challenging. This article develops new and modifies existing eye-tracking algorithms for the purpose of conducting meaningful ternary classification. To this end, a set of qualitative and quantitative behavior scores is introduced to facilitate the assessment of classification performance and to provide means for automated threshold selection. Experimental evaluation of the proposed methods is conducted using eye movement records obtained from 11 subjects at 1000 Hz in response to a step-ramp stimulus eliciting fixations, saccades, and smooth pursuits. Results indicate that a simple hybrid method that incorporates velocity and dispersion thresholding allows producing robust classification performance. It is concluded that behavior scores are able to aid automated threshold selection for the algorithms capable of successful classification.
24 February 2015 in IEEE Transactions on Information Forensics and Security
This paper investigates liveness detection techniques in the area of eye movement biometrics. We investigate a specific scenario, in which an impostor constructs an artificial replica of the human eye. Two attack scenarios are considered: 1) the impostor does not have access to the biometric templates representing authentic users, and instead utilizes average anatomical values from the relevant literature and 2) the impostor gains access to the complete biometric database, and is able to employ exact anatomical values for each individual. In this paper, liveness detection is performed at the feature and match score levels for several existing forms of eye movement biometric, based on different aspects of the human visual system. The ability of each technique to differentiate between live and artificial recordings is measured by its corresponding false spoof acceptance rate, false live rejection rate, and classification rate. The results suggest that eye movement biometrics are highly resistant to circumvention by artificial recordings when liveness detection is performed at the feature level. Unfortunately, not all techniques provide feature vectors that are suitable for liveness detection at the feature level. At the match score level, the accuracy of liveness detection depends highly on the biometric techniques employed.
1 May 2004 in Journal of Fluids Engineering
The flow developed behind shock wave transmitted through a screen or a perforated plat is initially highly unsteady and nonuniform. It contains multiple shock reflections and interactions with vortices shed from the open spaces of the barrier. The present paper studies experimentally and theoretically/numerically the flow and wave pattern resulted from the interaction of an incident shock wave with a few different types of barriers, all having the same porosity but different geometries. It is shown that in all investigated cases the flow downstream of the barrier can be divided into two different zones. Due immediately behind the barrier, where the flow is highly unsteady and nonuniform in the other, placed further downstream from the barrier, the flow approaches a steady and uniform state. It is also shown that most of the attenuation experienced by the transmitted shock wave occurs in the zone where the flow is highly unsteady. When solving the flow developed behind the shock wave transmitted through the barrier while ignoring energy losses (i.e., assuming the fluid to be a perfect fluid and therefore employing the Euler equation instead of the Navier-Stokes equation) leads to non-physical results in the unsteady flow zone.
8 December 2014 in ACM Transactions on Applied Perception
This article proposes and evaluates a novel biometric approach utilizing the internal, nonvisible, anatomical structure of the human eye. The proposed method estimates the anatomical properties of the human oculomotor plant from the measurable properties of human eye movements, utilizing a two-dimensional linear homeomorphic model of the oculomotor plant. The derived properties are evaluated within a biometric framework to determine their efficacy in both verification and identification scenarios. The results suggest that the physical properties derived from the oculomotor plant model are capable of achieving 20.3% equal error rate and 65.7% rank-1 identification rate on high-resolution equipment involving 32 subjects, with biometric samples taken over four recording sessions; or 22.2% equal error rate and 12.6% rank-1 identification rate on low-resolution equipment involving 172 subjects, with biometric samples taken over two recording sessions.