Earth Sciences Dept., Barcelona Supercomputing Centre - Centro Nacional de Supercomputación (BSC-CNS), Barcelona, Spain; Environmental Modelling Laboratory, Technical Univ. of Catalonia, Barcelona, Spain
Auto-generated profile, based on publicly available information
Robert F. Banks
Earth Sciences Dept., Barcelona Supercomputing Centre - Centro Nacional de Supercomputación (BSC-CNS), Barcelona, Spain; Environmental Modelling Laboratory, Technical Univ. of Catalonia, Barcelona, Spain
Air quality forecast systems need reliable and accurate representations of the planetary boundary layer (PBL) to perform well. An important question is how accurately numerical weather prediction models can reproduce conditions in diverse synoptic flow types. Here, observations from the summer 2014 HygrA-CD (Hygroscopic Aerosols to Cloud Droplets) experimental campaign are used to validate simulations from the Weather Research and Forecasting (WRF) model over the complex, urban terrain of the Greater Athens Area. Three typical atmospheric flow types were identified during the 39-day campaign based on 2-day backward trajectories: Continental, Etesians, and Saharan. It is shown that the numerical model simulations differ dramatically depending on the PBL scheme, atmospheric dynamics, and meteorological parameter (e.g., 2-m air temperature). Eight PBL schemes from WRF version 3.4 are tested with daily simulations on an inner domain at 1-km grid spacing. Near-surface observations of 2-m air temperature and relative humidity and 10-m wind speed are collected from multiple meteorological stations. Estimates of the PBL height come from measurements using a multiwavelength Raman lidar, with an adaptive extended Kalman filter technique. Vertical profiles of atmospheric variables are obtained from radiosonde launches, along with PBL heights calculated using bulk Richardson number. Daytime maximum PBL heights ranged from 2.57 km during Etesian flows, to as low as 0.37 km during Saharan flows. The largest differences between model and observations are found with simulated PBL height during Saharan synoptic flows. During the daytime, campaign-averaged near-surface variables show WRF tended to have a cool, moist bias with higher simulated wind speeds than the observations, especially near the coast. It is determined that non-local PBL schemes give the most agreeable solutions when compared with observations.Peer ReviewedPostprint (published version
1 December 2016 in Science of The Total Environment
Here we analyze the impact of four planetary boundary-layer (PBL) parametrization schemes from the Weather Research and Forecasting (WRF) numerical weather prediction model on simulations of meteorological variables and predicted pollutant concentrations from an air quality forecast system (AQFS). The current setup of the Spanish operational AQFS, CALIOPE, is composed of the WRF-ARW V3.5.1 meteorological model tied to the Yonsei University (YSU) PBL scheme, HERMES v2 emissions model, CMAQ V5.0.2 chemical transport model, and dust outputs from BSC-DREAM8bv2. We test the performance of the YSU scheme against the Assymetric Convective Model Version 2 (ACM2), Mellor-Yamada-Janjic (MYJ), and Bougeault-Lacarrère (BouLac) schemes. The one-day diagnostic case study is selected to represent the most frequent synoptic condition in the northeast Iberian Peninsula during spring 2015; regional recirculations. It is shown that the ACM2 PBL scheme performs well with daytime PBL height, as validated against estimates retrieved using a micro-pulse lidar system (mean bias=-0.11km). In turn, the BouLac scheme showed WRF-simulated air and dew point temperature closer to METAR surface meteorological observations. Results are more ambiguous when simulated pollutant concentrations from CMAQ are validated against network urban, suburban, and rural background stations. The ACM2 scheme showed the lowest mean bias (-0.96μgm-3) with respect to surface ozone at urban stations, while the YSU scheme performed best with simulated nitrogen dioxide (-6.48μgm-3). The poorest results were with simulated particulate matter, with similar results found with all schemes tested.
We evaluate planetary boundary-layer (PBL) parametrizations in the Weather Research and Forecasting (WRF) numerical model, with three connected objectives: first, for a 16-year period, we use a cluster analysis algorithm of three-day back-trajectories to determine general synoptic flow patterns over Barcelona, Spain arriving at heights of 0.5, 1.5, and 3 km; to represent the lower PBL, upper PBL, and lower free troposphere, respectively. Seven clusters are determined at each arriving altitude. Regional recirculations account for 54 % of the annual total at 0.5 km, especially in summertime. In the second objective, we assess a time-adaptive approach using an extended Kalman filter to estimate PBL height from backscatter lidar returns at 1200 UTC \(\pm \) 30 min for 45 individual days during a seven-year period. PBL heights retrieved with this technique are compared with three classic methods used in the literature to estimate PBL height from lidar. The methods are validated against PBL heights calculated from daytime radiosoundings. Lidar and radiosonde estimated PBL heights are classified under objectively-determined synoptic clusters. With the final objective, WRF model-simulated PBL heights are validated against lidar estimates using eight unique PBL schemes as inputs. Evaluation of WRF model-simulated PBL heights are performed under different synoptic situations. Determination coefficients with lidar estimates indicate the non-local assymetric convective model scheme is the most reliable, with the widely-tested local Mellor–Yamada–Janjic scheme showing the weakest correlations with lidar retrievals. Overall, there is a systematic underestimation of PBL height simulated in the WRF model.
This contribution evaluates an approach using an extended Kalman filter (EKF) to estimate the planetary boundary layer height (PBLH) from lidar measurements obtained in the framework of the European Aerosol Research LIdar NETwork (EARLINET) at 12 UTC ± 30-min for a 7-year period (2007-2013) under different synoptic flows over the complex geographical area of Barcelona, Spain. PBLH diagnosed with the EKF technique are compared with classic lidar methods and radiosounding estimates. Seven unique synoptic flows are identified using cluster analysis of 5756 HYSPLIT (HYbrid Single Particle Lagrangian Integrated Trajectory) three-day backtrajectories for a 16-year period (1998-2013) arriving at 0.5 km, 1.5 km, and 3 km, to represent the lower PBL, upper PBL, and low free troposphere, respectively. Regional recirculations are dominant with 54% of the annual total at 0.5 km and 57% of the total lidar days at 1.5 km, with a clear preference for summertime (0.5 km: 36% and 1.5 km: 29%). PBLH retrievals using the EKF method range from 0.79 - 1.6 km asl. The highest PBLHs are observed in southwest flows (15.2% of total) and regional recirculations from the east (34.8% of total), mainly caused by the stagnant synoptic pattern in summertime over the Iberian Peninsula. The lowest PBLHs are associated with north (19.6% of total) and northeast (4.3% of total) synoptic flows, when fresh air masses tend to lower PBLH. The adaptive nature of the EKF technique allows retrieval of reliable PBLH without the need for long time averaging or range smoothing, as typical with classic methodsAward-winningPostprint (published version
A training initiative in Europe opens doors for young scientists, promoting collaboration and broadening their skills with unique opportunities in atmospheric research.