16 September 2025 in Radiotherapy and Oncology
Based on prospectively uploaded treatment plans, a comprehensive analysis of the radiation therapy (RT) in the DBCG Skagen trial 1 is presented. From 2015 to 2021, 2963 breast cancer patients referred to adjuvant locoregional breast cancer RT after breast conserving surgery (BCS) or mastectomy were randomised to 50 Gy/25 fractions versus 40 Gy/15 fractions. Tumour-bed boost was simultaneous integrated boost (SIB). Delineated structure volumes were per ESTRO guidelines. Dosimetric data were obtained from the individual treatment plans. RT treatment plans from 2705 patients treated at 14 centres in 4 countries were analysed corresponding to 94 % of the per protocol patients. Overall, 1407 had BCS, 1298 had mastectomy, and 437 had SIB. The randomisation was balanced: 1329 (50 Gy) versus 1376 (40 Gy). All plans had target volume delineations per ESTRO guidelines. No significant differences were observed regarding delineated volumes nor regarding inter-centre variations per randomisation arm. Compliance to protocol constraints was generally high, however, the "hot-spot" dose compliance was higher in 50 Gy plans compared to 40 Gy plans due to stricter high dose constraints for the 40 Gy arm. The minimum coverage of target volumes was similar per randomisation arms. Respiratory gating technique was used in 83 % of the patients. When divided into subgroups per laterality and breathing technique, significantly higher lung and heart doses were detected in non-gated compared to gated plans. A high degree of protocol compliance was documented in the DBCG Skagen trial 1. No differences were observed among the treatment plans in the two randomisation arms.
30 September 2025 in Advances in Medical Pyhsics and Applied Sciences
Radiotherapy (RT) in lung cancer emphasizes the use of modern techniques due to the size of the treatment area and doses to critical organs. This study aimed to evaluate dosimetric differences between Helical Tomotherapy (HT) and Volumetric Arc Radiotherapy (VMAT) plans and which technique is more appropriate in patients with stage IIIB inoperable non-small cell lung cancer (NSCLC). Fifteen patients with stage IIIB inoperable NSCLC and a planning target volume (PTV) >200 cc or length >10 cm, treated between January 2024 and December 2024, were included. A prescription of 60 Gy in 30 fractions was applied. Plans were evaluated using conformity index (CI), homogeneity index (HI), and doses to critical organs. The median PTV volume was 385 cc (range: 213–615 cc). Both planning techniques covered 98% of the prescribed dose (p = 0.887), but HT demonstrated significantly better HI (p = 0.011). HT also yielded significantly lower doses in total lung V5, contralateral lung V5, heart mean dose, heart V50, and spinal cord max dose. Esophageal doses showed no significant differences. Although dose constraints for the esophagus were met in both planning systems, a lower dose was achieved with HT." Modern planning systems can achieve desired doses in large volume targets while remaining within dose limits for organs at risk. HT provided significant advantages in critical organ sparing and better homogeneity in dose distribution. The selection of the appropriate technique should be determined based on the characteristics of the tumor and the specific needs of the patient.
26 January 2025 in Advances in Medical Pyhsics and Applied Sciences
Purpose: Whole-brain irradiation is commonly used for patients with multiple brain metastases and poor performance status, often requiring rapid treatment planning. This study compares cone-beam computed tomography (CBCT)-based planning to conventional CT simulation for whole-brain radiotherapy (RT) to evaluate dosimetric differences and cost-effectiveness. Materials and Methods: Ten patients receiving palliative whole-brain RT at Acıbadem Atakent Hospital were included. Both CT simulation and CBCT images were used to create 3D conformal RT (3DCRT) plans. Brain and lens contours were marked, and dose calculations were performed with 6MV photon energy. Plans were normalized to ensure 95% of the target volume received 99,5% of the prescribed dose. Key metrics, including conformity index (CI), lens doses, maximum brain dose, brain volume, Hounsfield Units (HU), and monitor units (MU), were compared using the Wilcoxon test. Findings: Results showed no significant differences in lens contouring or CI between CBCT- and CT-based plans. Brain volume was significantly larger in CBCT images, and CBCT-based plans had higher maximum doses and MU values due to HU adjustments. However, HU values themselves did not differ significantly. Conclusion: CBCT-based planning demonstrated shorter processing times and reduced workload, making it more efficient economically. With proper calibration, CBCT planning offers a viable alternative for urgent whole-brain RT planning, providing comparable dose and plan quality to CT-based methods.