Optical tracking system (OTS) is widely used in robot orthopedic surgeries. During the surgery, the locomotion of the surgical instrument along different osteotomy planes and the adjustment of the patient’s body will lead to obvious variations on the spatial relationship among the positioning tools. Usually, the OTS is manually placed at a fixed viewpoint. As the size of the measurement volume (MV) of the OTS is limited, some positioning tools might move towards the boundaries of the MV, increasing the risk of navigation failure. This paper proposes a two-phase optimization scheme for the active online adjusting of the OTS viewpoint to guarantee the consistency of navigation. A novel optimization structure is proposed with the consideration of continuous state inequality constraints. The dynamic accuracy of the OTS during the active adjusting is also demonstrated to be reliable. Ultimately, simulations and experiments are performed on an active navigation system to verify the effectiveness of the proposed two-phase optimization scheme. Experimental results show that the OTS can be moved to the optimal viewpoint smoothly when confronted with significant variations on the spatial relationship among the positioning tools, guaranteeing the consistency of navigation. The navigation robot successfully keeps the positioning tools around the central region of the MV at different surgical phases.
30 August 2023 in IEEE Transactions on Medical Robotics and Bionics
Optical tracking system (OTS) plays a significant role in orthopedic surgeries to track the relative position and orientation between the surgical tool and the patient’s lesion via markers. Typically, OTS is placed in a fixed pose and remains static throughout the surgery. However, the measurement volume (MV) of OTS is limited. With the movements of the surgical tool or the patient, the markers might move beyond the MV, causing navigation failure. To address this challenge, this paper proposes a real-time optimization-based tracking method to actively adjust the observation view of the OTS and guarantee the consistency of intraoperative navigation. Specifically, the continuously tracking of markers is formulated into an optimization problem, where minimum and maximum angle optimization functions are designed to ensure surgical safety. The dynamic accuracy of the OTS is also evaluated to be reliable during the adjusting process. Ultimately, simulations and phantom experiments are performed on an active navigation system to verify the effectiveness of the proposed optimization tracking method. Experimental results show that the OTS can always track all markers when confronted with moving markers. The navigation robot successfully keeps the markers within the MV of the OTS.
Intraoperative optical tracking system (OTS) suffers from the visual occlusion problem when an obstacle blocks the visual cone (VC) of the OTS. In this paper, angle and distance margins are proposed to quantify the degree of danger of an obstacle based on its spatial relationship to the VCs of the OTS. Based on this mathematical modeling, an active navigation system is proposed, where the navigation robot is used to adjust the pose of the OTS before occlusion occurs. Circular and translational trajectories are proposed as basic adjusting trajectories for the OTS. A dual-step optimization is then established to find the optimal observation pose of the OTS and plan an occlusion-free adjusting trajectory for the navigation robot. Finally, simulations and experiments are conducted to validate the effectiveness of the proposed method. The results demonstrate that the proposed method effectively keeps the VCs of the OTS away from the moving path of the obstacle, and thus maintaining consistent navigation. This active navigation method is promising for the safe operations of surgical systems employing optical navigation.
Optical navigation is the mainstream technology used in intraoperative navigation for the orthopedic surgical robot. The information loss problem in optical navigation system (OTS) seriously affects the surgical process. Different from the conventional orthopedic surgical robot systems, we propose to use an additional navigation robot to adjust the viewpoint of the OTS. In this navigation-operation dual-robot collaborative robotic system for orthopedic surgery (NOR2CORS), a comprehensive range of functions are realized, including CT image segmentation, path planning, intraoperative operation, and active navigation. In this paper, pedicle screw placement is adopted as an example to assess the effectiveness and performance of the NOR2CORS. An assessment criterion is also proposed to assess the accuracy of pedicle screw placement based on the widely-used Gertzbein and Robbins classification. Experiments are conducted on a human spine model (24 pedicles) and ex-vivo porcine spine (10 pedicles). According to the proposed assessment criterion, 96% pedicles on human spine model can be classified as grade A and 4% grade B, with 67% of them as grade A2 and above. In the ex-vivo porcine spine experiment, all pedicle screw placements can be classified as grade A, with 80% of them as grade A2 and above. In the surgical process, all positioning targets can be observed without any interruption in navigation. These results demonstrated the efficiency and accuracy of the NOR2CORS.