Guosheng Liu

Guosheng Liu

Auto-generated profile, based on publicly available information

Guosheng Liu

Changsha University of Science and Technology, Changsha, CHINA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2023 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
YXYixiang Xia
Yixiang Xia
ZLZewen Li
Zewen Li
YXYanhui Xi
Yanhui Xi
YFYixuan Feng
Yixuan Feng
GWGuorui Wu
Guorui Wu
GLGuosheng Liu
Guosheng Liu
This study aims to address the challenge of fault location in distribution networks with closed-loop structures. We propose a comprehensive method that focuses on two aspects: traveling wave head calibration and fault location. By analyzing the propagation properties of hybrid lines traveling waves, we demonstrate the feasibility of optimizing wave speed using time difference measurements. To solve the time calibration problem of weak fault signals, we utilize the signal cumulative deviation curve to select the time window of fault mutation, and then develop a novel wide scale time window difference operator for accurate calibration. Finally, we use a positioning method based on dynamic virtual faults to optimize wave speed and accurately locate faults in both overhead and cable lines. We build an improved IEEE 118 node network using power system simulation software (PSCAD) for simulation verification, which shows that our proposed method can accurately calibrate the initial wavefront time of fault traveling waves and precisely locate the fault positions.

13 May 2025 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
GWGuorui Wu
Guorui Wu
ZLZewen Li
Zewen Li
YXYixiang Xia
Yixiang Xia
GLGuosheng Liu
Guosheng Liu
YWYuanchuan Wang
Yuanchuan Wang
SCSixu Chen
Sixu Chen
To address the issues of location accuracy in traveling wave (TW) network location methods, which are susceptible to clock synchronization errors and TW speed inaccuracies. We propose a TW network location method based on virtual fault time difference information, simulating the propagation of TWs using virtual faults (VFs). Theoretically, the study analyzes the impact of transition resistance and TW heads (TWHs) aliasing on TWHs calibration, proposing an optimal effective time difference criterion that is unaffected by these factors. Algorithmically, VFs are first set in the faulty line, and a path search algorithm is used to obtain all TWH paths from the VF point to the measurement points. Subsequently, based on the optimal effective time difference selection criteria for different fault areas, steps such as filtering VF wave head paths and simulating virtual fault TWHs yield the optimal time difference matrix for the VFs. The accuracy of the VF location is assessed by calculating the degree of difference between the time difference information of virtual and real faults. An optimization algorithm continuously adjusts the VF point location and TW speed, gradually converging the VF point to the real fault point until they coincide, at which point the VF location corresponds to the real fault location. Verified by the PSCAD simulation platform, the proposed method can achieve precise fault location under various fault types, transition resistances, and noise interferences.

1 January 2026 in IEEE Transactions on Industrial Informatics
Verified
Journal Article
Closed access
GWGuorui Wu
Guorui Wu
YXYixiang Xia
Yixiang Xia
ZLZewen Li
Zewen Li
GLGuosheng Liu
Guosheng Liu
RDRenjie Deng
Renjie Deng
SRShen Ren
Shen Ren

10 April 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
GWGuorui Wu
Guorui Wu
ZLZewen Li
Zewen Li
YXYixiang Xia
Yixiang Xia
GLGuosheng Liu
Guosheng Liu
CHChenguang Hu
Chenguang Hu
KLKe Li
Ke Li
Addressing the challenges brought by complex hybrid ring networks in fault section location and accurate location, this paper proposes a hybrid transmission network traveling wave (TW) location method based on fault deduction and wave speed optimization. First, the paper analyzes the TW propagation process and establishes equivalent models for each stage of the propagation process, deriving initial TW relationships between measurement points. Based on this, the fault deduction algorithm determines the TW propagation paths, enabling network decomposition of complex hybrid ring lines. Combining the concept of virtual fault (VF), a fault section location model is established, and the fault section is determined by maximizing the similarity of VF waveforms. Utilizing the TW arrival time in non-fault areas after network decomposition, a TW speed optimization model is established to obtain the optimal TW speed solution for the region, achieving accurate location. Verified by the PSCAD simulation platform, this method can accurately locate the fault section and determine the optimal TW speed in complex hybrid ring network scenarios, achieving accurate fault location.