22 October 2019 in medRxiv
Restoring somatosensory feedback to people with limb amputations is crucial for improving prosthesis acceptance and function. Epidural spinal cord stimulation is a commonly used clinical procedure that targets sensory neural pathways in the dorsal spinal cord to treat pain conditions. A similar approach could be developed as a clinically translatable means to restore somatosensation in amputees. We show that epidural stimulation of the dorsal spinal cord evoked sensory percepts, perceived as emanating from the amputated arm and hand, in four people with upper-limb amputation. After an initial caudal movement immediately following the implantation, the leads stabilized, exhibiting a median migration of <5 mm (each electrode contact is 3 mm long) over the remainder of the study in all the subjects. This was reflected in the consistent locations of evoked percepts in the hand across four subjects throughout the period of implantation, which lasted up to 29 days. The median change in the centroid location was 1.2 to 35.3 mm and the median change in percept area was 0 to 40%. While most of the evoked percepts were paresthetic in nature, a subset was described as naturalistic (e.g. touch or pressure) in three subjects. Modulating the stimulus amplitude affected the perceived intensity of the sensation in all subjects. A variety of sensory percepts were evoked in all subjects irrespective of the level of amputation or the time since amputation, suggesting the approach is amenable to a diverse population of amputees.
10 September 2023 in medRxiv
Background: People with lower-limb amputations lack sensory inputs from their missing limb, which increases their risk of falling. We recently demonstrated that spinal cord stimulation (SCS) can restore sensation in the missing lower limb. Previous studies have shown that SCS can affect motor control by exciting spinal reflex pathways after stroke or spinal cord injury. The effects of SCS on spinal reflex activation have not been studied in people with lower-limb amputation. Furthermore, it is unknown if SCS-evoked spinal reflex activation would perturb walking. Therefore, the goal of this study was to characterize SCS-evoked spinal reflexes in people with lower-limb amputation and quantify effects on gait parameters, including step cycle duration and limb alternation symmetry. Methods: We implanted percutaneous SCS electrodes over the lumbosacral enlargement in 3 people with trans-tibial amputation (2 diabetic neuropathy; 1 traumatic) for 28 or 84 days. SCS was delivered to restore sensation in the missing limb during walking based on signals from a pressure-sensing insole in the shoe under the prosthesis. We used electromyography (EMG) to record posterior root-muscle (PRM) reflexes in the residual limb while participants were seated, standing, or walking. We characterized rate-dependent depression and recruitment properties of the PRM reflexes. We used pressure data from instrumented insoles to measure the step cycle duration and limb alternation symmetry with and without SCS. Results: SCS evoked PRM reflexes in the residual limb muscles in all participants, which was confirmed by the presence of rate-dependent depression at stimulation frequencies ≥2Hz. Overall, there was broad activation of residual limb muscles with SCS that varied with the position of the stimulating electrode relative to the lumbar spinal cord. PRM reflexes were also activated during walking, as confirmed by the presence of rate-dependent depression. However, SCS-evoked PRM reflexes did not disrupt gait, with similar step cycle duration or limb alternation symmetry with and without SCS. Conclusions: Restoring sensation in the missing limb using SCS excites spinal reflexes according to the expected rostral-caudal myotomes but does not disrupt the step cycle duration or limb alternation symmetry in people with trans-tibial amputation.
31 March 2025 in Frontiers in Surgery
Introduction: Epidural spinal cord stimulation (SCS) is a clinical neuromodulation technique that is commonly used to treat neuropathic pain, with patients typically undergoing a one-week percutaneous trial phase before permanent implantation. Traditional SCS involves stimulation of the thoracic spinal cord, but there has been substantial recent interest in cervical SCS to treat upper extremity pain, restore sensation from the missing hand after amputation, or restore motor function to paretic limbs in people with stroke and spinal cord injury. Because of the additional mobility of the neck, as compared to the trunk, lead migration can be a major challenge for cervical SCS, especially during the percutaneous trial phase. The objective of this study was to optimize the implantation procedure of cervical SCS leads to minimize lead migration and increase lead stability during SCS trials.Methods: In this study, four subjects underwent percutaneous placement of three SCS leads targeting the cervical spinal segments as part of a clinical trial aiming to restore sensation for people with upper-limb amputation. The leads were maintained for up to 29 days and weekly x-ray imaging was used to measure rostrocaudal and mediolateral lead migration based on bony landmarks.Results and discussion: Lead migration was primarily confined to the rostrocaudal axis with the most migration occurring during the first week. Iterative improvements to the implantation procedure were implemented to increase lead stability across subjects. There was a decrease in lead migration for patients who had more rostral placement of the SCS leads. The average migration from the day of lead implant to lead removal was 29.7 mm for Subject 1 (lead placement ranging from T3-T4 to T1-T2), 41.9 mm for Subject 2 (T2-T3 to C7-T1), 1.9 mm for Subject 3 (T1-T2 to C7-T1), and 16.6 mm for Subject 4 (T1-T2 to C7-T1). We found that initial placement of spinal cord stimulator leads in the cervical epidural space as rostral as possible was critical to minimizing subsequent rostrocaudal lead migration.