23 November 2021 in IEEE Transactions on Industry Applications
Better reliability of power supply is assured with the inculcation of DGs in a distribution network. Smart sensors and latest grid communication protocols have played a crucial role in the development of intelligent MGs. Conventional protection schemes do not provide reliable performance when implemented in MGs. This paper proposes an approach which requires root mean square value of one cycle three phase voltage and current measurements during fault. These data are treated as inputs for developing a fault isolation and locator module. This module is supposed to be available at central protection system, and is designed using ML based techniques viz. GPR for fault location prediction and SVM for fault identification. Effectiveness of the proposed methodology is evaluated by considering practical grid scenarios with load variation and different DG penetration level. Further, the robustness of the proposed model is assessed by performing sensitivity analysis with consideration of variation in line parameters and load as well as effect of DG correlation. A 7-bus meshed AC MG test system consisting of three DGs and two grid sources is modelled in SIMULINK platform, and is used to demonstrate the proposed module. Data analytics tools of MATLAB 2020a has been explored to develop a machine learning-based fault isolation and location module for MGs. The proposed scheme has also been validated with real time MG data obtained from OPAL-RT real time simulator OP-4510. The accuracy in predicted results proves that the proposed scheme is pertinent for real time practical applications.
1 July 2016 in Renewable and Sustainable Energy Reviews
16 January 2024 in IEEE Transactions on Industry Applications
Frequency Regulation (FR) is vulnerable to cyber-attacks due to their reliance on modern communication technologies. These attacks can disrupt the coordination between sub-components of the hybrid power system by influencing the communication between sensors, control centers, and actuators. Attackers can jam, alter or even delay the signals from sensors and control centers, which can severely impact power system operation. To maintain power system stability and reliability, it is imperative to develop a resilient FR mechanism that can withstand these threats. This article proposes a deep-learning-based Attack Detection and Mitigation (ADM) system for the cyber-physical model in FR analysis and an enhanced dual loop TI-LADRC with feed-forward topology for the amelioration of FR performance in the grid. ADM system estimates compares, and replaces Area Control Error (ACE) to detect and mitigate Denial of Service (DoS), False Data Injection (FDI), and Time Delay (TD) attacks. The case study is performed on a modified IEEE 39-bus and IEEE 118-bus system, considering the stochastic behavior of Renewable Energy Sources (RESs) and actual load fluctuations to ensure the efficacy of the proposed control scheme. Furthermore, real-time analysis using OPAL-RT OP5700 is presented to validate the resiliency of the control strategy and ensure improved FR analysis.
12 April 2022 in IEEE Transactions on Industry Applications
This article presents the impact of Demand Response (DR) on an identical restructured two-area power system considering communication latency. DR is emerging as a leading approach for the future electric power system, ameliorating the system reliability and frequency stability. Each test area comprises of a solar photovoltaic, wind turbine, biogas unit, traditional thermal power plant and an assets of electric vehicles (EVs). In this study, a hybrid hierarchical DR control mechanism is developed by incorporating the inherent communication latency in the loop. The stability of the investigated system with and without DR is compared in terms of stability margin to illustrate the significance of DR on system stability.The Quasi- Oppositional Harris Hawks Optimization (QOHHO) technique is used to optimize the coefficients of the proposed hybrid two degree of freedom (Proportional Integral Derivative)-Linear Active Disturbance Rejection Control (TDOF-LADRC). The proposed controller's efficacy in terms of system dynamics is contrasted with LADRC in order to examine its adequacy for the studied power system. Moreover, the practical feasibility of the proposed technique is demonstrated through experimental validation utilizing OPAL-RT based real-time simulation followed with analysis.
1 February 2018 in Renewable and Sustainable Energy Reviews
1 June 2013 in International Journal of Electrical Power & Energy Systems