Clare Marie Rimnac

Clare Marie Rimnac

Auto-generated profile, based on publicly available information

Clare Marie Rimnac

Senior Editor, Clinical Orthopaedics and Related Research®, Schaumburg, IL, USA

Research Focus & Metrics

Academic Career Length

46Years (1981-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2009 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
MSM.C. Sobieraj
M.C. Sobieraj
CRC.M. Rimnac
C.M. Rimnac

13 June 2013 in Clinical Orthopaedics and Related Research
Verified
Journal Article
Open access
PDF file
SKSteven Kurtz
Steven Kurtz
SKSevi B. Kocagöz
Sevi B. Kocagöz
JHJosa A. Hanzlik
Josa A. Hanzlik
RURichard J. Underwood
Richard J. Underwood
JGJeremy L. Gilbert
Jeremy L. Gilbert
CRClare M. Rimnac
Clare M. Rimnac
Background Previous studies regarding modular head-neck taper corrosion were largely based on cobalt chrome (CoCr) alloy femoral heads. Less is known about head-neck taper corrosion with ceramic femoral heads. Questions/purposes We asked (1) whether ceramic heads resulted in less taper corrosion than CoCr heads; (2) what device and patient factors influence taper fretting corrosion; and (3) whether the mechanism of taper fretting corrosion in ceramic heads differs from that in CoCr heads. Methods One hundred femoral head-stem pairs were analyzed for evidence of fretting and corrosion using a visual scoring technique based on the severity and extent of fretting and corrosion damage observed at the taper. A matched cohort design was used in which 50 ceramic head-stem pairs were matched with 50 CoCr head-stem pairs based on implantation time, lateral offset, stem design, and flexural rigidity. Results Fretting and corrosion scores were lower for the stems in the ceramic head cohort (p = 0.03). Stem alloy (p = 0.004) and lower stem flexural rigidity (Spearman’s rho = −0.32, p = 0.02) predicted stem fretting and corrosion damage in the ceramic head cohort but not in the metal head cohort. The mechanism of mechanically assisted crevice corrosion was similar in both cohorts although in the case of ceramic femoral heads, only one of the two surfaces (the male metal taper) engaged in the oxide abrasion and repassivation process. Conclusions The results suggest that by using a ceramic femoral head, CoCr fretting and corrosion from the modular head-neck taper may be mitigated but not eliminated. Clinical Relevance The findings of this study support further study of the role of ceramic heads in potentially reducing femoral taper corrosion.

1 July 1994 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
CRClare Rimnac
Clare Rimnac
RKRobert Klein
Robert Klein
FBFoster Betts
Foster Betts
TWTimothy Wright
Timothy Wright
A study was performed to determine the time-course of oxidative degradation and the extent to which the degradation proceeded through the bulk of ultra-high molecular weight polyethylene joint components that had been irradiated and stored on a shelf. Standardized cylindrical samples, taken

1 September 2002 in Biomaterials
Verified
Journal Article
Closed access
SKSteven Kurtz
Steven Kurtz
MVM.L Villarraga
M.L Villarraga
MHM.P Herr
M.P Herr
JBJ.S Bergström
J.S Bergström
CRC.M Rimnac
C.M Rimnac
AEA.A Edidin
A.A Edidin

1 March 2006 in Biomaterials
Verified
Journal Article
Closed access
SGSara J. Gencur
Sara J. Gencur
CRClare M. Rimnac
Clare M. Rimnac
SKSteven M. Kurtz
Steven M. Kurtz

1 September 2001 in Journal of Orthopaedic Research
Verified
Journal Article
Closed access
OAOzan Akkus
Ozan Akkus
CRClare M. Rimnac
Clare M. Rimnac