Russell H. Taylor

Russell H. Taylor

Auto-generated profile, based on publicly available information

Russell H. Taylor

Computer Science Department, The Johns Hopkins University, Baltimore, MD, USA

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 1999 in Medical Image Analysis
Verified
Journal Article
Open access
RTRussell H. Taylor
Russell H. Taylor
LJLeo Joskowicz
Leo Joskowicz
BWBill Williamson
Bill Williamson
AGAndré Guéziec
André Guéziec
AKAlan Kalvin
Alan Kalvin
ALArmin Lahmer
Armin Lahmer
This paper describes an ongoing project to develop a computer-integrated system to assist surgeons in revision total hip replacement (RTHR) surgery. In RTHR surgery, a failing orthopedic hip implant, typically cemented, is replaced with a new one by removing the old implant, removing the cement and fitting a new implant into an enlarged canal broached in the femur. RTHR surgery is a difficult procedure fraught with technical challenges and a high incidence of complications. The goals of the computer-based system are the significant reduction of cement removal labor and time, the elimination of cortical wall penetration and femur fracture, the improved positioning and fit of the new implant resulting from precise, high-quality canal milling and the reduction of bone sacrificed to fit the new implant. Our starting points are the ROBODOC system for primary hip replacement surgery and the manual RTHR surgical protocol. We first discuss the main difficulties of computer-integrated RTHR surgery and identify key issues and possible solutions. We then describe possible system architectures and protocols for preoperative planning and intraoperative execution. We present a summary of methods and preliminary results in CT image metal artifact removal, interactive cement cut-volume definition and cement machining, anatomy-based registration using fluoroscopic X-ray images and clinical trials using an extended RTHR version of ROBODOC. We conclude with a summary of lessons learned and a discussion of current and future work.


1 October 1997
Verified
Journal Article
Closed access
JCJ A Cadeddu
J A Cadeddu
ABA Bzostek
A Bzostek
SSS Schreiner
S Schreiner
ABA C Barnes
A C Barnes
WRW W Roberts
W W Roberts
LKL R Kavoussi
L R Kavoussi

24 August 2005
Verified
Conference Paper
Closed access
RTR.H. Taylor
R.H. Taylor
PKPeter Kazanzides
Peter Kazanzides
BMB.D. Mittelstadt
B.D. Mittelstadt
HPH.A. Paul
H.A. Paul

31 December 2002
Verified
Conference Paper
Closed access
PDF file
LJL. Joskowicz
L. Joskowicz
RTR.H. Taylor
R.H. Taylor
An implemented algorithm for determining if an implant can be successfully inserted into a cavity is presented. The program computes an insertion trajectory consisting of small implant motion steps. Motion steps are computed by solving a series of linear optimization problems whose solution corresponds to the maximum allows displacement in a preferred direction satisfying localized motion constraints. The program implements a greedy, search-free algorithm to find a monotone trajectory in a preferred direction to any desired resolution. The program has been successfully tested on real cases Author(s) Joskowicz, L. IBM T.J. Watson Res. Center, Yorktown Heights, NY, USA Taylor, R.H.