Joo H. Kim

Joo H. Kim

Auto-generated profile, based on publicly available information

Joo H. Kim

Department of Mechanical and Aerospace Engineering, Polytechnic Institute of New York University, Brooklyn, NY, USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 July 2013 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
Carlotta MummoloCarlotta Mummolo
Carlotta Mummolo
LMLuigi Mangialardi
Luigi Mangialardi
JKJoo H. Kim
Joo H. Kim
Normal human walking typically consists of phases during which the body is statically unbalanced while maintaining dynamic stability. Quantifying the dynamic characteristics of human walking can provide better understanding of gait principles. We introduce a novel quantitative index, the dynamic gait measure (DGM), for comprehensive gait cycle. The DGM quantifies the effects of inertia and the static balance instability in terms of zero-moment point and ground projection of center of mass and incorporates the time-varying foot support region (FSR) and the threshold between static and dynamic walking. Also, a framework of determining the DGM from experimental data is introduced, in which the gait cycle segmentation is further refined. A multisegmental foot model is integrated into a biped system to reconstruct the walking motion from experiments, which demonstrates the time-varying FSR for different subphases. The proof-of-concept results of the DGM from a gait experiment are demonstrated. The DGM results are analyzed along with other established features and indices of normal human walking. The DGM provides a measure of static balance instability of biped walking during each (sub)phase as well as the entire gait cycle. The DGM of normal human walking has the potential to provide some scientific insights in understanding biped walking principles, which can also be useful for their engineering and clinical applications.

31 March 2010 in Multibody System Dynamics
Verified
Journal Article
Closed access
PDF file
JKJoo H. Kim
Joo H. Kim
YXYujiang Xiang
Yujiang Xiang
JYJingzhou Yang
Jingzhou Yang
JAJasbir S. Arora
Jasbir S. Arora
KAKarim Abdel-Malek
Karim Abdel-Malek

15 October 2012 in Robotica
Verified
Journal Article
Closed access
PDF file
Carlotta MummoloCarlotta Mummolo
Carlotta Mummolo
JKJoo H. Kim
Joo H. Kim
SUMMARY: Understanding and mimicking human gait is essential for design and control of biped walking robots. The unique characteristics of normal human gait are described as passive dynamic walking, whereas general human gait is neither completely passive nor always dynamic. To study various walking motions, it is important to quantify the different levels of passivity and dynamicity, which have not been addressed in the current literature. In this paper, we introduce the initial formulations of Passive Gait Measure (PGM) and Dynamic Gait Measure (DGM) that quantify passivity and dynamicity, respectively, of a given biped walking motion, and the proposed formulations will be demonstrated for proof-of-concepts using gait simulation and analysis. The PGM is associated with the optimality of natural human walking, where the passivity weight functions are proposed and incorporated in the minimization of physiologically inspired weighted actuator torques. The PGM then measures the relative contribution of the stance ankle actuation. The DGM is associated with the gait stability, and quantifies the effects of inertia in terms of the Zero-Moment Point and the ground projection of center of mass. In addition, the DGM takes into account the stance foot dimension and the relative threshold between static and dynamic walking. As examples, both human-like and robotic walking motions during single support phase are generated for a planar biped system using the passivity weights and proper gait parameters. The calculated PGM values show more passive nature of human-like walking as compared with the robotic walking. The DGM results verify the dynamic nature of normal human walking with anthropomorphic foot dimension. In general, the DGMs for human-like walking are greater than those for robotic walking. The resulting DGMs also demonstrate their dependence on the stance foot dimension as well as the walking motion; for a given walking motion, smaller foot dimension results in increased dynamicity. Future work on experimental validation and demonstration will involve actual walking robots and human subjects. The proposed results will benefit the human gait studies and the development of walking robots.

25 July 2013 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
DRDustyn Roberts
Dustyn Roberts
HKHumera Khan
Humera Khan
JKJoo H Kim
Joo H Kim
JSJames Slover
James Slover
PWPeter S Walker
Peter S Walker
There is no universally accepted definition of human joint stability, particularly in nonperiodic general activities of daily living. Instability has proven to be a difficult parameter to define and quantify, since both spatial and temporal measures need to be considered to fully characterize joint stability. In this preliminary study, acceleration-based parameters were proposed to characterize the joint stability. Several time-statistical parameters of acceleration and jerk were defined as potential stability measures, since anomalous acceleration or jerk could be a symptom of poor control or stability. An inertial measurement unit attached at the level of the tibial tubercle of controls and patients following total knee arthroplasty was used to determine linear acceleration of the knee joint during several activities of daily living. The resulting accelerations and jerks were compared with patient-reported instability as determined through a standard questionnaire. Several parameters based on accelerations and jerks in the anterior/posterior direction during the step-up/step-down activity were significantly different between patients and controls and correlated with patient reports of instability in that activity. The range of the positive to negative peak acceleration and infinity norm of acceleration, in the anterior/posterior direction during the step-up/step-down activity, proved to be the best indicators of instability. As time derivatives of displacement, these acceleration-based parameters represent spatial and temporal information and are an important step forward in developing a definition and objective quantification of human joint stability that can complement the subjective patient report.

7 March 2011 in International Journal for Numerical Methods in Engineering
Verified
Journal Article
Closed access
PDF file
JKJoo H. Kim
Joo H. Kim
KAKarim Abdel‐Malek
Karim Abdel‐Malek
YXYujiang Xiang
Yujiang Xiang
JYJingzhou (James) Yang
Jingzhou (James) Yang
JAJasbir S. Arora
Jasbir S. Arora

2 July 2013 in Multibody System Dynamics
Verified
Journal Article
Closed access
PDF file
JKJoo H. Kim
Joo H. Kim
CJChang B. Joo
Chang B. Joo