Matias Hemmilä

Matias Hemmilä

Auto-generated profile, based on publicly available information

Matias Hemmilä

University of Turku Department of Clinical Medicine, Turku, Southwest Finland, Finland

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2020 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
APAntton Palomäki
Antton Palomäki
MHMatias Hemmilä
Matias Hemmilä
ILInari Laaksonen
Inari Laaksonen
MMMarkus Matilainen
Markus Matilainen
AEAntti Eskelinen
Antti Eskelinen
KMKeijo T Makela
Keijo T Makela
Background: To enhance osseointegration in total hip arthroplasty (THA), ultraporous or highly porous-coated cups were introduced. Implant survival data on these new devices have been scarce. The aim of our study was to assess the survivorship of ultraporous Tritanium cups (Stryker) in a population-based register study. Methods: In this study, we collected data on 6,080 primary THAs using a Tritanium cup and 25,670 THAs using a conventional cup (control group) from the Finnish Arthroplasty Register; these procedures were performed from January 1, 2009, to December 31, 2017. We calculated the Kaplan-Meier survival estimates with 95% confidence intervals (CIs). The end point was revision for any reason or for aseptic loosening of the cup. The revision risks were assessed with use of the Cox multiple regression model. The variables assessed in the Cox model were femoral head size, age group, involved side, operation year, sex, diagnosis, and fixation of the stem. The proportional hazards assumption of the Cox model was not fulfilled, so the follow-up time was divided into 3 time periods: 0 to 2 years, >2 to 4 years, and >4 years. Results: When comparing the 2 groups with regard to revision for any reason, the 5-year Kaplan-Meier survivorship of the Tritanium group (94.7% [95% CI, 94.0% to 95.4%]) was inferior to that of the control group (96.0% [95% CI, 95.7% to 96.3%]). In the Cox regression analysis of the 2 groups for the time period of >4 years, the Tritanium group had an increased risk of revision for any reason compared with the control group (hazard ratio [HR], 3.12 [95% CI, 1.82 to 5.35]; p < 0.001). With regard to revision for aseptic loosening of the cup, the Tritanium group had an increased risk of revision compared with the control group for both 0 to 2 years (HR, 3.80 [95% CI, 1.76 to 8.24]; p < 0.001) and >2 to 4 years (HR, 11.2 [95% CI, 3.28 to 38.0]; p < 0.001). Conclusions: There was no advantage to using the ultraporous-coated Tritanium cup for primary THA compared with conventional uncemented cups. However, wide CIs for some HR estimates may point to a lack of precision. Therefore, further research on subject is needed. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

19 November 2025 in Journal of Bone and Joint Surgery
Verified
Journal Article
Open access
HKHannes Keemu
Hannes Keemu
ESEetu Syystö
Eetu Syystö
Riku KlénRiku Klén
Riku Klén
MVMikko S. Venäläinen
Mikko S. Venäläinen
MHMatias Hemmilä
Matias Hemmilä
KMKeijo T Makela
Keijo T Makela
Background: Debridement, antibiotics, and implant retention (DAIR) is the method of choice in the treatment of acute periprosthetic joint infection (PJI). However, the optimal timing of DAIR is somewhat unclear. We assessed the success of DAIR performed during different time intervals after primary total hip arthroplasty (THA) and total knee arthroplasty (TKA) using data from the Finnish Arthroplasty Register (FAR). Methods: There were 178,498 primary operations (78,888 THAs and 99,610 TKAs) from May 2014 to April 2022 recorded in the FAR. Male patients represented 53.4% of the THA group and 55.5% of the TKA group. The most common age group was ≤62 years in the THA group and ≥76 years in the TKA group. All patients were of Finnish ethnicity. A total of 1,014 DAIR procedures were performed within 6 months after the primary arthroplasty. Cases of reoperation after DAIR were followed for 1 year after the DAIR; re-revision due to PJI within 1 year was regarded as a failure of the DAIR treatment. We compared the failure rate of DAIR among 3 time intervals: 0 to 42, 43 to 84, and 85 to 180 days after the primary operation. A Cox regression model was used to assess risk factors for re-revision. Results: In the THA group, the failure rate was 15.1% when DAIR was performed within 42 days, 10.0% when performed at 43 to 84 days, and 31.4% when performed at 85 to 180 days after the primary THA. In the TKA group, the failure rate was 8.9% when DAIR was performed within 42 days, 16.7% when performed at 43 to 84 days, and 9.8% when performed at 85 to 180 days after the primary TKA. Later DAIR was not associated with an increased re-revision risk, compared with the reference of 0 to 42 days, in the THA group (43 to 84 days: hazard ratio [HR], 1.2 [95% confidence interval (CI), 0.6 to 2.2; p = 0.63]; 85 to 180 days: HR, 1.4 [95% CI, 0.6 to 3.0; p = 0.41]). The same was true in the TKA group (43 to 84 days: HR, 1.0 [95% CI, 0.4 to 2.4; p = 0.98]; 85 to 180 days: HR, 1.9 [95% CI, 1.0 to 3.8; p = 0.065]). Conclusions: The failure rate of DAIR may not increase as much as previously thought if performed >6 weeks after primary total joint arthroplasty. Thus, DAIR can also be worth considering as a treatment method for PJI beyond the first 6 weeks postoperatively, depending on the severity of the case. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.

24 November 2022 in Acta Orthopaedica
Verified
Journal Article
Open access
PDF file
APAntton Palomäki
Antton Palomäki
MHMatias Hemmilä
Matias Hemmilä
MMMarkus Matilainen
Markus Matilainen
AEAntti Eskelinen
Antti Eskelinen
JHJaason Haapakoski
Jaason Haapakoski
KMKeijo T Mäkelä
Keijo T Mäkelä
Background and purpose: Long-term outcome of small head (28 mm) metal-on-metal (MoM) total hip arthroplasty (THA) is available mainly for Metasul devices (Sulzer Medica, Winterthur, Switzerland). Biomet MoM THA was frequently used in Finland. Therefore, we assessed long-term survivorship of the M2a 28-mm RingLoc MoM THA (Biomet, Warsaw, IN, USA) and compared it with the metal-on-polyethylene (MoP) RingLoc THA from the same manufacturer.Patients and methods: We conducted a register study based on THAs from the Finnish Arthroplasty Register performed between January 1, 2000 and December 31, 2007. 290 28-mm head M2a MoM THAs and 1,647 28-mm head MoP THAs (reference group) were included. The endpoint was revision for any reason, or revision for aseptic loosening, osteolysis, liner wear, or metallosis as one group. Kaplan–Meier survival estimates were calculated, and revision risks were assessed using a Cox multiple regression model, both with 95% confidence intervals (CI).Results: No difference was found in the 15-year Kaplan–Meier survivorship between the 28-mm head M2a RingLoc MoM THA and the reference group for any reason for revision (87.7% [82.9–92.1] and 83.3% [81.0–85.3], respectively). The adjusted hazard ratio (HR) for any reason for revision for the MoM THA group compared with the reference group was at least equal or better (0.70 [0.48–1.02]). Both groups presented similar survival for revision for aseptic loosening of the cup, osteolysis, liner wear, or metallosis, at 96.2% (92.7–98.0) and 95.4% (93.9–96.5), respectively.Interpretation: In the long-term survival there was no difference between the M2a 28-mm RingLoc MoM THA and 28-mm MoP THA. Further follow-up regimens for M2a 28-mm RingLoc THA patients may be unnecessary, but long-term metal ion and radiological data is needed before any formal suggestions.

19 August 2026 in BMJ Open
Verified
Journal Article
Open access
PDF file
EAElias Autio
Elias Autio
TVTero Vahlberg
Tero Vahlberg
EEElina M. Ekman
Elina M. Ekman
ILInari Laaksonen
Inari Laaksonen
MHMatias Hemmilä
Matias Hemmilä
KMKeijo T Makela
Keijo T Makela
Objective: Metal-on-metal (MoM) total hip arthroplasty (THA) and hip-resurfacing arthroplasty were widely used worldwide, including in Finland, at the beginning of the century. This study aimed to assess the long-term cancer risk among all Finnish patients with any kind of MoM hip device and to compare it with that of the general Finnish population and patients with conventional THA. Design: Population-based study. Setting: Nationwide retrospective comparative register-based study. Participants: A total of 18 922 patients who underwent MoM hip arthroplasty (HA) and 29 247 patients who underwent conventional THA (reference cohort) were recorded in the Finnish Arthroplasty Register (FAR) between 2001 and 2013. Data on cases of cancer up to 2021 for these cohorts were extracted from the Finnish Cancer Registry (FCR). Data from the FAR and FCR, as well as information on deaths from the Population Register Centre, were linked using personal identification codes. Main outcome measures: The relative risk of cancer was expressed as the ratio of the observed to expected number of cases in the Finnish population using the standardised incidence ratio (SIR). Poisson regression was used to estimate the relative risk of cancer in the MoM cohort compared with the non-MoM cohort as a ratio of SIRs. Results: The overall risk of cancer in the MoM cohort was decreased compared with that of the general Finnish population (1381 observed versus 1521 expected; SIR 0.91; 95% CI 0.86 to 0.96; p<0.001). The overall cancer risk in the MoM cohort was similar to that of the non-MoM cohort (SIR ratio 0.94; 95% CI 0.88 to 1.00). Basal cell carcinoma and melanoma risks in the MoM cohort were increased compared with that of the general Finnish population (991 observed vs 918 expected; SIR 1.08; 95% CI 1.01 to 1.15; p=0.02, and 167 observed vs 143 expected; SIR 1.17; 95% CI 1.00 to 1.36; p=0.05, respectively). However, the basal cell carcinoma and melanoma risks between the MoM and the non-MoM cohorts were similar (SIR ratio 1.05; 95% CI 0.97 to 1.14, and SIR ratio 1.20; 95% CI 0.97 to 1.47, respectively). Conclusions: MoM HA was not associated with increased overall cancer risk, even in the long term. The melanoma, basal cell carcinoma and prostate findings should be interpreted cautiously because they are increased versus the general population but not versus conventional THA. Longer follow-up periods may be needed to clarify the risks of skin and prostate cancers.