Shilin Zhao

Shilin Zhao

Auto-generated profile, based on publicly available information

Shilin Zhao

Department of Cancer Biology, Vanderbilt University, Nashville, TN, USA

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
SZShilin Zhao
Shilin Zhao
Yan GuoYan Guo
Yan Guo
QSQuanhu Sheng
Quanhu Sheng
YSYu Shyr
Yu Shyr
Heat maps and clustering are used frequently in expression analysis studies for data visualization and quality control. Simple clustering and heat maps can be produced from the “heatmap” function in R. However, the “heatmap” function lacks certain functionalities and customizability, preventing it from generating advanced heat maps and dendrograms. To tackle the limitations of the “heatmap” function, we have developed an R package “heatmap3” which significantly improves the original “heatmap” function by adding several more powerful and convenient features. The “heatmap3” package allows users to produce highly customizable state of the art heat maps and dendrograms. The “heatmap3” package is developed based on the “heatmap” function in R, and it is completely compatible with it. The new features of “heatmap3” include highly customizable legends and side annotation, a wider range of color selections, new labeling features which allow users to define multiple layers of phenotype variables, and automatically conducted association tests based on the phenotypes provided. Additional features such as different agglomeration methods for estimating distance between two samples are also added for clustering.

1 May 2014 in Genomics
Verified
Journal Article
Closed access
Yan GuoYan Guo
Yan Guo
SZShilin Zhao
Shilin Zhao
QSQuanhu Sheng
Quanhu Sheng
FYFei Ye
Fei Ye
JLJiang Li
Jiang Li
YSYu Shyr
Yu Shyr

27 May 2014 in BioMed Research International
Verified
Journal Article
Open access
PDF file
Yan GuoYan Guo
Yan Guo
SZShilin Zhao
Shilin Zhao
FYFei Ye
Fei Ye
QSQuanhu Sheng
Quanhu Sheng
YSYu Shyr
Yu Shyr
Background. After a decade of microarray technology dominating the field of high-throughput gene expression profiling, the introduction of RNAseq has revolutionized gene expression research. While RNAseq provides more abundant information than microarray, its analysis has proved considerably more complicated. To date, no consensus has been reached on the best approach for RNAseq-based differential expression analysis. Not surprisingly, different studies have drawn different conclusions as to the best approach to identify differentially expressed genes based upon their own criteria and scenarios considered. Furthermore, the lack of effective quality control may lead to misleading results interpretation and erroneous conclusions. To solve these aforementioned problems, we propose a simple yet safe and practical rank-sum approach for RNAseq-based differential gene expression analysis named MultiRankSeq. MultiRankSeq first performs quality control assessment. For data meeting the quality control criteria, MultiRankSeq compares the study groups using several of the most commonly applied analytical methods and combines their results to generate a new rank-sum interpretation. MultiRankSeq provides a unique analysis approach to RNAseq differential expression analysis. MultiRankSeq is written in R, and it is easily applicable. Detailed graphical and tabular analysis reports can be generated with a single command line.

12 October 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
Yan GuoYan Guo
Yan Guo
SZShilin Zhao
Shilin Zhao
QSQuanhu Sheng
Quanhu Sheng
MGMingsheng Guo
Mingsheng Guo
BLBrian Lehmann
Brian Lehmann
YSYu Shyr
Yu Shyr
The most popular RNA library used for RNA sequencing is the poly(A) captured RNA library. This library captures RNA based on the presence of poly(A) tails at the 3′ end. Another type of RNA library for RNA sequencing is the total RNA library which differs from the poly(A) library by capture method and price. The total RNA library costs more and its capture of RNA is not dependent on the presence of poly(A) tails. In practice, only ribosomal RNAs and small RNAs are washed out in the total RNA library preparation. To evaluate the ability of detecting RNA for both RNA libraries we designed a study using RNA sequencing data of the same two breast cancer cell lines from both RNA libraries. We found that the RNA expression values captured by both RNA libraries were highly correlated. However, the number of RNAs captured was significantly higher for the total RNA library. Furthermore, we identify several subsets of protein coding RNAs that were not captured efficiently by the poly(A) library. One of the most noticeable is the histone-encode genes, which lack the poly(A) tail.

24 September 2015 in BMC Genomics
Verified
Journal Article
Open access
PDF file
Yan GuoYan Guo
Yan Guo
ABAmma Bosompem
Amma Bosompem
SMSanjay Mohan
Sanjay Mohan
BEBegum Erdogan
Begum Erdogan
FYFei Ye
Fei Ye
AKAnnette S. Kim
Annette S. Kim
Although advances in sequencing technologies have popularized the use of microRNA (miRNA) sequencing (miRNA-seq) for the quantification of miRNA expression, questions remain concerning the optimal methodologies for analysis and utilization of the data. The construction of a miRNA sequencing library selects RNA by length rather than type. However, as we have previously described, miRNAs represent only a subset of the species obtained by size selection. Consequently, the libraries obtained for miRNA sequencing also contain a variety of additional species of small RNAs. This study looks at the prevalence of these other species obtained from bone marrow aspirate specimens and explores the predictive value of these small RNAs in the determination of response to therapy in myelodysplastic syndromes (MDS). Paired pre and post treatment bone marrow aspirate specimens were obtained from patients with MDS who were treated with either azacytidine or decitabine (24 pre-treatment specimens, 23 post-treatment specimens) with 22 additional non-MDS control specimens. Total RNA was extracted from these specimens and submitted for next generation sequencing after an additional size exclusion step to enrich for small RNAs. The species of small RNAs were enumerated, single nucleotide variants (SNVs) identified, and finally the differential expression of tRNA-derived species (tDRs) in the specimens correlated with diseasestatus and response to therapy. Using miRNA sequencing data generated from bone marrow aspirate samples of patients with known MDS (N = 47) and controls (N = 23), we demonstrated that transfer RNA (tRNA) fragments (specifically tRNA halves, tRHs) are one of the most common species of small RNA isolated from size selection. Using tRNA expression values extracted from miRNA sequencing data, we identified six tRNA fragments that are differentially expressed between MDS and normal samples. Using the elastic net method, we identified four tRNAs-derived small RNAs (tDRs) that together can explain 67 % of the variation in treatment response for MDS patients. Similar analysis of specifically mitochondrial tDRs (mt-tDRs) identified 13 mt-tDRs which distinguished disease status in the samples and a single mt-tDR which predited response. Finally, 14 SNVs within the tDRs were found in at least 20 % of the MDS samples and were not observed in any of the control specimens. This study highlights the prevalence of tDRs in RNA-seq studies focused on small RNAs. The potential etiologies of these species, both technical and biologic, are discussed as well as important challenges in the interpretation of tDR data. Our analysis results suggest that tRNA fragments can be accurately detected through miRNA sequencing data and that the expression of these species may be useful in the diagnosis of MDS and the prediction of response to therapy.

7 January 2017 in BMC Genomics
Verified
Journal Article
Open access
PDF file
Yan GuoYan Guo
Yan Guo
KVKasey Vickers
Kasey Vickers
YXYanhua Xiong
Yanhua Xiong
SZShilin Zhao
Shilin Zhao
QSQuanhu Sheng
Quanhu Sheng
CFCharles R Flynn
Charles R Flynn
DNA and RNA fractions from whole blood, serum and plasma are increasingly popular analytes that are currently under investigation for their utility in the diagnosis and staging of disease. Small non-coding ribonucleic acids (sRNAs), specifically microRNAs (miRNAs) and their variant isoforms (isomiRs), and transfer RNA (tRNA)-derived small RNAs (tDRs) comprise a repertoire of molecules particularly promising in this regard. In this designed study, we compared the performance of various methods and kits for isolating circulating extracellular sRNAs (ex-sRNAs). ex-sRNAs from one healthy individual were isolated using five different isolation kits: Qiagen Circulating Nucleic Acid Kit, ThermoFisher Scientific Ambion TRIzol LS Reagent, Qiagen miRNEasy, QiaSymphony RNA extraction kit and the Exiqon MiRCURY RNA Isolation Kit. Each isolation method was repeated four times. A total of 20 small RNA sequencing (sRNAseq) libraries were constructed, sequenced and compared using a rigorous bioinformatics approach. The Circulating Nucleic Acid Kit had the greatest miRNA isolation variability, but had the lowest isolation variability for other RNA classes (isomiRs, tDRs, and other miscellaneous sRNAs (osRNA). However, the Circulating Nucleic Acid Kit consistently generated the fewest number of reads mapped to the genome, as compared to the best-performing method, Ambion TRIzol, which mapped 10% of the miRNAs, 7.2% of the tDRs and 23.1% of the osRNAs. The other methods performed intermediary, with QiaSymphony mapping 14% of the osRNAs, and miRNEasy mapping 4.6% of the tDRs and 2.9% of the miRNAs, achieving the second best kit performance rating overall. In summary, each isolation kit displayed different performance characteristics that could be construed as biased or advantageous, depending upon the downstream application and number of samples that require processing.