Francisco Hernán Sepúlveda Palma

Francisco Hernán Sepúlveda Palma

Auto-generated profile, based on publicly available information

Francisco Hernán Sepúlveda Palma

Laboratorio de Metrología Térmica, Universidad de Santiago de Chile

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2021 in Measurement
Verified
Journal Article
Closed access
AMAdriana Machado Malafaia da Mata
Adriana Machado Malafaia da Mata
Bruno Furtado de MouraBruno Furtado de Moura
Bruno Furtado de Moura
Márcio Ferreira MartinsMárcio Ferreira Martins
Márcio Ferreira Martins
FPFrancisco Hernán Sepúlveda Palma
Francisco Hernán Sepúlveda Palma
RRRogério Ramos
Rogério Ramos

1 December 2021 in Measurement
Verified
Journal Article
Closed access
Bruno Furtado de MouraBruno Furtado de Moura
Bruno Furtado de Moura
MMMarcio Ferreira Martins
Marcio Ferreira Martins
FPFrancisco Hernán Sepúlveda Palma
Francisco Hernán Sepúlveda Palma
WSWellington Betencurte da Silva
Wellington Betencurte da Silva
JCJorge Acevedo Cabello
Jorge Acevedo Cabello
RRRogério Ramos
Rogério Ramos

19 January 2020 in Buildings
Verified
Journal Article
Open access
PDF file
JBJuan Pablo Bravo
Juan Pablo Bravo
TVTomás Venegas
Tomás Venegas
ECElizabeth Correa
Elizabeth Correa
AAalejandro alamos
alejandro alamos
FSFrancisco Sepúlveda
Francisco Sepúlveda
Camila BarrenecheCamila Barreneche
Camila Barreneche
The application of phase change materials (PCM) in the thermal envelope of buildings has proven to be an alternative to reduce energy consumption and to improve thermal comfort conditions. The present work evaluates the thermal behavior of gypsum boards modified with a microencapsulated PCM (mPCM) in a cubic test enclosure, considering the climatic conditions of Santiago de Chile in the September–November period of 2017. The design of the test enclosure was performed considering the minimization of parameters that affect the variation of its inner temperature and favoring the heat flow through the gypsum boards. Experimentally, the results reflect the main effects of the implementation of a mPCM, among which the displacement of the maximum heat load and the decrease in the daily oscillation of the internal temperature of the test enclosure (up to 2 °C) stand out. In addition, the mPCM modified gypsum board was thermally characterized to carry out a thermal simulation of the enclosures using EnergyPlus™. The obtained numerical results agree with those obtained experimentally, including the behavior of the transient heat flux through the gypsum boards. Moreover, it was found that considering a null infiltration rate gives place to unrealistic results, suggesting that this parameter should be controlled.

1 September 2020 in IEEE Latin America Transactions
Verified
Journal Article
Closed access
Bruno Furtado de MouraBruno Furtado de Moura
Bruno Furtado de Moura
Márcio Ferreira MartinsMárcio Ferreira Martins
Márcio Ferreira Martins
FPFrancisco Hernán Sepúlveda Palma
Francisco Hernán Sepúlveda Palma
WSWellington Betencurte da Silva
Wellington Betencurte da Silva
JCJorge Acevedo Cabello
Jorge Acevedo Cabello
RRRogério Ramos
Rogério Ramos
Electrical Resistance Tomography (ERT) is a technique employed in the industrial environment that reconstructs images formed by the impedance distributions inside a vessel. The method relies on measures from a data acquisition system, responsible to inject a current inside the vessel and measures the voltage on the boundaries, and sequentially an inverse problem solution. This paper introduces a low-cost design of an acquisition system that can obtain 30 images/s with a signal-to-noise ratio of 57.47 dB and a maximum error of 3.79%. It utilizes a simple RMS-to-DC converter demodulation scheme to provide good accessibility to researchers aimed at investigating flow patterns of multiphase flow applications.

1 April 2021 in Measurement
Verified
Journal Article
Closed access
AMAdriana Machado Malafaia da Mata
Adriana Machado Malafaia da Mata
Bruno Furtado de MouraBruno Furtado de Moura
Bruno Furtado de Moura
Márcio Ferreira MartinsMárcio Ferreira Martins
Márcio Ferreira Martins
FPFrancisco Hernán Sepúlveda Palma
Francisco Hernán Sepúlveda Palma
RRRogério Ramos
Rogério Ramos

23 December 2021 in IEEE Latin America Transactions
Verified
Journal Article
Closed access
Bruno Furtado de MouraBruno Furtado de Moura
Bruno Furtado de Moura
AMAdriana Machado Malafaia da Mata
Adriana Machado Malafaia da Mata
Márcio Ferreira MartinsMárcio Ferreira Martins
Márcio Ferreira Martins
FPFrancisco Hernan Sepulveda Palma
Francisco Hernan Sepulveda Palma
RRRogério Ramos
Rogério Ramos
Electrical Impedance Tomography (EIT) is a technique that enables the reconstruction of the impedance distributions inside a vessel in a multiphase flow of industrial processes. Such a technique combines a data acquisition (DAQ) system to inject a current and to measure the voltages on the sensors and an inverse problem technique to reconstruct the image properly. This problem is highly ill-conditioned, causing errors to produce instabilities. Therefore, when performing the acquisition, the DAQ system must have adequate accuracy to allow the reconstruction of images with good quality. To avoid these measurement inaccuracies, this paper introduces a methodology that aid in the process of development of low-cost systems. It consists of investigating the errors in the current version of the system. Further, predicting the systematic errors of each subsystem by modeling its frequency response by Simulation Program with Integrated Circuit Emphasis (SPICE). From this information, it is possible to perform critical analysis, aiding design decisions.