13 May 2021 in Nature Communications
Animal behavior usually has a hierarchical structure and dynamics. Therefore, to understand how the neural system coordinates with behaviors, neuroscientists need a quantitative description of the hierarchical dynamics of different behaviors. However, the recent end-to-end machine-learning-based methods for behavior analysis mostly focus on recognizing behavioral identities on a static timescale or based on limited observations. These approaches usually lose rich dynamic information on cross-scale behaviors. Here, inspired by the natural structure of animal behaviors, we address this challenge by proposing a parallel and multi-layered framework to learn the hierarchical dynamics and generate an objective metric to map the behavior into the feature space. In addition, we characterize the animal 3D kinematics with our low-cost and efficient multi-view 3D animal motion-capture system. Finally, we demonstrate that this framework can monitor spontaneous behavior and automatically identify the behavioral phenotypes of the transgenic animal disease model. The extensive experiment results suggest that our framework has a wide range of applications, including animal disease model phenotyping and the relationships modeling between the neural circuits and behavior.
30 January 2024 in Frontiers in Neuroscience
Background and purpose: The differential diagnosis between solid glioma and brain inflammation is necessary but sometimes difficult. We assessed the effectiveness of multiple diffusion metrics of diffusion-weighted imaging (DWI) in differentiating solid glioma from brain inflammation and compared the diagnostic performance of different DWI models.Materials and methods: Participants diagnosed with either glioma or brain inflammation with a solid lesion on MRI were enrolled in this prospective study from May 2016 to April 2023. Diffusion-weighted imaging was performed using a spin-echo echo-planar imaging sequence with five b values (500, 1,000, 1,500, 2000, and 2,500 s/mm2) in 30 directions for each b value, and one b value of 0 was included. The mean values of multiple diffusion metrics based on diffusion tensor imaging (DTI), diffusion kurtosis imaging (DKI), mean apparent propagator (MAP), and neurite orientation dispersion and density imaging (NODDI) in the abnormal signal area were calculated. Comparisons between glioma and inflammation were performed. The area under the curve (AUC) of the receiver operating characteristic curve (ROC) of diffusion metrics were calculated.Results: 57 patients (39 patients with glioma and 18 patients with inflammation) were finally included. MAP model, with its metric non-Gaussianity (NG), shows the greatest diagnostic performance (AUC = 0.879) for differentiation of inflammation and glioma with atypical MRI manifestation. The AUC of DKI model, with its metric mean kurtosis (MK) are comparable to NG (AUC = 0.855), followed by NODDI model with intracellular volume fraction (ICVF) (AUC = 0.825). The lowest value was obtained in DTI with mean diffusivity (MD) (AUC = 0.758).Conclusion: Multiple diffusion metrics can be used in differentiation of inflammation and solid glioma. Non-Gaussianity (NG) from mean apparent propagator (MAP) model shows the greatest diagnostic performance for differentiation of inflammation and glioma.
4 December 2025 in Physics in Medicine & Biology
Objective. To evaluate how medical metal implants influence T 1 and T 2 mapping in magnetic resonance imaging (MRI), focusing on relaxation quantification accuracy and repeatability. Approach. The National Institute of Standards and Technology/International Society for Magnetic Resonance in Medicine phantom was scanned on three 3 T MRI systems at different sites using variable flip angle (VFA), multi-echo fast spin echo (ME-FSE), and MR fingerprinting (MRF). Repeatability and accuracy were assessed, followed by analysis of the effects of aneurysm clips, cranial plates, and orthodontic materials. Main results. Coefficient of variation of 2.44%–10.81% for VFA/ME-FSE and 1.67%–16.31% for MRF. Deviations from reference values ranged from 5.96%–132.26% for VFA/ME-FSE and −36.87%–17.17% for MRF. When metal implants were introduced, VFA remained more robust for T 1 mapping while MRF and ME-FSE only quantified spheres distal to the metal reliably. B 0 / B 1 + mapping sequence effectively delineated artifact boundaries and guide reliable regions for relaxometry imaging. Significance. Medical metal implants can substantially affect relaxation quantification in MRI, with distortion severity depending on implant type and distance. These findings highlight the importance of accounting for these effects when interpreting quantitative MRI results in both clinical and research settings.