24 July 2020 in Journal of Pediatric Orthopaedics B
MAMehmet Cemalettin Aksoy
Risk factors for rebound phenomenon (ReP) have not been investigated in detail. Aim of this study is to investigate risk factors of ReP in lower extremity deformities after two-hole plate removal. Patients who underwent hemiepiphysiodes were retrospectively reviewed. Joint orientation angles of tibia and femur, deformity type, age of patient at initial surgery and plate removal, deformity correction rate, bone growth rate were noted. An increase of 5° or more in joint orientation angles in the direction of the initial deformity was considered ReP. A relationship between the patient parameters and ReP was evaluated. Ninety-four segments (55 femurs and 39 tibias) of 43 patients (15 males and 28 females) were included. ReP was observed in 56.2% of all valgus deformities (n = 73), and in 23.8% of varus deformities (n = 21). The ReP rate was 60% (n = 27) and 20% (n = 2) in femoral segments with preoperative valgus and varus deformities, respectively (P = 0.03). When gender, etiology, sides and age of implant application and removal were compared, there was no difference between ReP(+) and ReP(−) groups in femur and tibia. The correction rate of mechanical lateral distal femoral angle in ReP(−) and ReP(+) femurs was 0.7 ± 0.4°/month and 1.1 ± 0.3°/month, respectively (P = 0.01). Age at implant application and removal in the femoral valgus group was significantly lower in the ReP(+) group (P = 0.008 and P = 0.005, respectively). The ReP rate was higher in femoral segments with overcorrection (P = 0.008). The ReP rate was higher in femoral valgus deformities. Younger age at plate application and removal, higher correction rate in deformity and intentional overcorrection increased risk for ReP.
22 March 2006 in Skeletal Radiology
14 July 2022 in Journal of Pediatric Orthopaedics
Background: Subtrochanteric femur fractures are unstable injuries due to strong muscle forces on the proximal femur. The ideal fixation device is controversial in the treatment of subtrochanteric femur fractures in children. The aim of this study is to evaluate the clinical and radiological outcomes of subtrochanteric femur fractures in children treated with an adult proximal humerus plate. Methods: A total of 9 patients [mean age at surgery, 8.3 years (range: 7 to 12); mean follow-up period, 28.1 months (range: 12 to 56)] who underwent surgery due to a subtrochanteric femur fracture and treated with an adult proximal humerus between January 2017 and December 2021 were retrospectively evaluated. Four of the patients had a pathological fracture associated with a benign bone tumor while 5 patients had a nonpathological fracture. The clinical and radiological outcomes were assessed using the Flynn scoring system at the latest follow-up. Time to union and complications were recorded. Results: All patients demonstrated a solid fusion of the fracture site and were able to bear full weight at the latest follow-up. The mean time to union was 8.2 weeks (range: 6 to 10). Based on the Flynn scoring system at the latest follow-up, seven patients had excellent clinical outcomes and two patients had satisfactory outcomes. Two patients had limb length discrepancy, and one patient had coxa valga and a limb length discrepancy of 16 mm. There were no patients with nonunion, infection, implant failure, osteonecrosis of the femoral head, and heterotopic bone formation. Conclusion: This study suggests that the adult proximal humerus plate may be an effective alternative fixation option in the treatment of subtrochanteric femur fractures in children, including pathological fractures. Level of Evidence: Level IV, Case series
1 August 2023 in Journal of Pediatric Orthopaedics
MAMehmet Cemalettin Aksoy
+1
Background: The present study aims to investigate the frequency of recurrence and tethering effect after only metaphyseal screw removal (sleeper plate technique) compared with the conventional complete plate removal in the treatment of lower extremity deformities with guided growth surgery. Methods: Seventy-two patients (107 limbs) treated by an 8-plate hemiepiphysiodesis technique around the knee joint were evaluated. After the desired correction, only metaphyseal screw was removed (sleeper plate group) in 35 limbs (25 patients), whereas both screws and plate were removed (plate removal group) in 72 limbs (47 patients). An increase of 5 degrees or more in joint orientation angles in the direction of the initial deformity was considered as recurrence. The rate of rebound, tethering, and maintenance of correction in groups was analyzed at the latest follow-up (mean of 49 mo). Results: The mean age of the patients was 97 months (range: 80 to 129 mo) at the time of index surgery. After a mean of 49 months (range: 16 to 86), 17 (48.5%) limbs maintained the desired stable correction in the sleeper plate group compared with 59 stable limbs (72.2%) in the plate removal group (P<0.001). There was no statistically significant difference regarding recurrence between the sleeper plate group and the plate removal group (34.3% vs. 27.8%, respectively) (P=0.216). Reinsertion of the metaphyseal screw was possible 8/12 limbs, and the remaining 4 limbs underwent further surgeries. There were 6 limbs (17.3%) of tethering in the sleeper plate group, and 4/6 limbs required further corrective surgeries. The remaining 2 limbs with slight tethering did not require further surgeries. Conclusions: Removing only metaphyseal screw increases the risk of tethering. In addition, reinsertion of the screw may not be possible in all cases due to bony growth, and further corrective surgeries may be necessary. Close follow-up is required if the sleeper plate technique is to be applied. Level of Evidence: Level III.
4 September 2021 in The Knee