João Victor Cunha Cordeiro

João Victor Cunha Cordeiro

Auto-generated profile, based on publicly available information

João Victor Cunha Cordeiro

PhD student, Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Piracicaba, São Paulo, Brazil

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 February 2025 in Dentomaxillofacial Radiology
Verified
Journal Article
Open access
LBLauren Bohner
Lauren Bohner
HPHian Parize
Hian Parize
JCJoão Victor Cunha Cordeiro
João Victor Cunha Cordeiro
NLNatalia Koerich Laureano
Natalia Koerich Laureano
JKJohannes Kleinheinz
Johannes Kleinheinz
DDDorothea C. Dagassan-Berndt
Dorothea C. Dagassan-Berndt
Objectives: The purpose of this study was to evaluate how artefacts caused by titanium and zirconia dental implants affect the bone quality assessment in CBCT images. The effect of scan mode and the use of metal artefact reduction (MAR) algorithm on artefacts suppression were taken in consideration. Methods: Titanium and zirconia dental implants were installed in porcine bone samples and scanned with two CBCT devices with adjustments on scan mode and with the use of MAR. The control group consisted of bone sample without implant and scanned with full-rotation scan mode without MAR. Artefacts extension and bone quality around implants were measured by deviation of grey values and bone histomorphometry measurements (trabecular volume fraction, bone specific surface, trabecular thickness, and trabecular separation), respectively. Mean difference among groups was assessed by within ANOVA with Bonferroni correction. Correlation between bone quality measurements acquired in the experimental and control groups was assessed by Spearman correlation test (α = .05). Results: No statistical difference was found for artefacts extension in images acquired by half and full-rotation modes (P = .82). The application of MAR reduced artefacts caused by titanium and zirconia dental implants, showing no statistically significant difference from the control group (titanium: P = .20; zirconia: P = .31). However, there was no correlation between bone quality measurements (P < .05). Conclusions: Bone quality assessment was affected by the presence of artefacts caused by dental implants. Rotation mode did not affect the appearance of artefacts and bone qualitative measurements. MAR was able to decrease artefacts, however, it did not improve the accuracy of bone quality measurements.

9 October 2025 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Open access
BMBruno Bragança Rodrigues Matias
Bruno Bragança Rodrigues Matias
FFFábio José Persegani Oliva da Fonseca
Fábio José Persegani Oliva da Fonseca
JCJoão Victor Cunha Cordeiro
João Victor Cunha Cordeiro
LBLauren Bohner
Lauren Bohner
NSNewton Sesma
Newton Sesma
Despite advancements in digitally assisted dentistry, the digital workflow still presents limitations in challenging clinical situations. New artificial intelligence (AI)-assisted tools and the reverse scan technique can be used to improve the digital workflow for complete arch implant-supported prostheses, ensuring an accurate and predictable treatment workflow. The present report describes the integration of AI-assisted esthetic virtual simulation to a reverse scan body recording for complete mouth implant-supported prostheses.

20 September 2025 in Journal of Prosthodontics
Verified
Journal Article
Open access
JCJoão Victor Cunha Cordeiro
João Victor Cunha Cordeiro
LBLauren Bohner
Lauren Bohner
FZFernanda Pretto Zatt
Fernanda Pretto Zatt
ASArtur Ferronato Soto
Artur Ferronato Soto
HSHenrique Souza dos Santos
Henrique Souza dos Santos
RCRicardo Armini Caldas
Ricardo Armini Caldas
A technique is described to obtain a 3D‐printed custom tray for complete dentures through open‐source, free software and additive manufacturing. This approach enables the production of custom trays in a cost‐effective and optimized manner. A three‐dimensional (3D) digital cast is obtained by photogrammetry and later used to design a digital custom tray. Then, the digital custom tray is manufactured by a 3D printer to be used in clinical procedures. This technique is a clean, rapid, and low‐cost alternative to the traditional technique.