26 April 2021 in Frontiers in Energy Research
This paper presents a region boundaries determination method for critical commutation failures (CF) in multi-infeed high-voltage direct-current (HVDC) systems under unbalanced short circuit faults. By using the nodal impedance matrix, a calculation approach for the converter extinction angles is deduced. First, the extinction angles under unbalanced short circuit faults are calculated. If the extinction angle of a bus is less than the minimum extinction angle, the bus is a failed bus set. By this means, region boundaries of critical commutation failures are demarcated by examining each bus in the AC system. Finally, the effectiveness of the proposed approach was verified by using a modified IEEE 39-bus system.
21 May 2021 in Frontiers in Energy Research
Electromechanical transient (EMT) and transient stability hybrid simulations can make full use of their fast-solving ability and high-precision computing ability to accurately simulate the dynamic characteristics of large-scale AC/DC systems. This paper selects the bus as the hybrid simulation interface bus in the AC system near the DC system, which can effectively improve the simulation accuracy of the AC/DC system interaction. At the interface bus, Norton equivalent and Thevenin equivalent are applied to the EMT simulation side and electromechanical transient simulation side, respectively. The three-phase simulation data and three-sequence component simulation data are extracted respectively, and the serial iteration method is used for hybrid simulation calculation. This paper takes Zhangbei multi terminal AC/DC system as an example, compares the hybrid simulation results with the EMT simulation results, and tries to verify the accuracy and effectiveness of the hybrid simulation method.
31 August 2021 in Mathematical Problems in Engineering
A method of rapidly demarcating the critical commutation failure (CF) region of a multi-infeed high-voltage direct-current (HVDC) system is proposed. Based on the nodal impedance matrix and nodal voltage interaction factor, for different AC fault conditionsboth balanced and unbalanceda method of calculating the extinction angles of converters in multi-infeed HVDC systems is deduced in detail. First, the extinction angles of convertor stations under single-phase, double-phase, and three-phase ground faults and line-to-line faults occurring at any bus in an AC system are calculated. The minimum extinction angle serves as a CF criterion. If the calculated extinction angle for a certain bus is smaller than the minimum extinction angle, then a fault at that bus will cause CF of the HVDC system and put that bus into a failed bus set. The critical failure impedance boundaries of the topology diagram can therefore be demarcated by examining every bus in the AC system. The validity and accuracy of the proposed index and the method were verified by calculation results based on the three-infeed HVDC system model of the IEEE 39-bus system. Finally, the critical failure impedance boundary was demarcated in the IEEE 118-bus system to demonstrate the application in a wider range of systems.