18 April 2024 in IEEE Transactions on Instrumentation and Measurement
With the development of both distribution automation and management system in distribution grid, the fault location methods based on wide-area measurement show great potential. Timely fault location based on wide-area measurements depends largely on the computing time of the algorithm. In addition, the meters layout method also affects the cost and accuracy of fault location. In this article, the efficiency of sparse Bayesian learning (SBL) algorithm and the meter configuration strategy for distributed grid fault location have been improved. Different from the previous calculation for all parameters in the multidimensional vector of Bayesian learning, the proposed method uses the $\boldsymbol {K}$ -means algorithm to extract partial parameters in the vector for update, which improves the computational efficiency without reducing the reconstruction accuracy. Then, for the sparse meter configuration using the principle of sparse recovery, which can be optimized by improving the coherence principle of the sensing matrix, the simulation results show that the improved Bayesian learning of the proposed $\boldsymbol {K}$ -means algorithm significantly improves the computational efficiency, regardless of low- or high-dimensional signals. At the same time, use the low coherence principle of sparse recovery to guide the meter configuration in distribution grid, which could increase the overall fault location accuracy of about 4% compared to recent work. To verify the effectiveness, the performance of the method is tested on IEEE standard 69 bus distribution grids. Simulation results indicate that the suggested strategy performs well for various scenarios.
5 October 2022 in Journal of Physics: Condensed Matter
The quantum anomalous Hall (QAH) effect has recently drawn great attention in spintronics with extraordinary property of chiral edge states without dissipation in absence of magnetic field. In M2X3 honeycomb Kagome lattice, numerous two-dimensional materials are predicted to be QAH insulators including metal oxides/sulfides and metal organic lattice. In this work, we proposed a general model to explain the mechanism of Dirac half metal with absence of spin orbital coupling and the nontrivial topological property with spin orbital coupling, which could be induced by combination of electron counting rule, crystal field effect and orbitals hybridization. Based on the mechanism, we further predict that triphenyl-metal lattice M2(C6H4)3 (M = V, Nb, Ta) are all QAH insulators with high Curie temperature and large nontrivial band gap for triphenyl-Nb and triphenyl-Ta lattice.
16 November 2023 in IEEE Transactions on Instrumentation and Measurement
Topology reconstruction is of great importance for fault location in smart grids. However, with the increasing development of grid infrastructure, the measurement perturbation increases and the topology reconstruction accuracy decreases. By analyzing the topology sparsity variation of the power grid before and after faults, a new method for fault location based on topology recognition is proposed. Traditional Bayesian inference with synthesized noise term is introduced to solve the measurement perturbation problem, and a fixed-point iteration method is adopted for inference to solve intractable posterior in Bayesian learning. Extensive simulations are conducted to verify the feasibility of the method, which show that the root mean square error (RMSE) of the proposed method is lower than 0.03 when the noise level varies from $5\mathrm {e}^{-6}$ to $5\mathrm {e}^{-3}$ . The fault location results are more accurate compared with traditional methods when facing ground fault. The proposed method is of great significance for fault location under unknown topology information.
17 April 2024 in IEEE Sensors Journal
Monitoring technology for partial discharges (PD) in Air-Insulated Substations (AIS) has undergone development and practical application. Partial discharge positioning based on Received Signal Strength Indication (RSSI) faces a variety of interference factors, including complex environments, multipath effects of signals, expensive fees and huge size of monitoring equipment. These factors jointly lead to the decline of PD positioning accuracy. In order to solve these problems, this paper proposes a substation patrol vehicle positioning technology based on RSSI and vehicle-mounted UHF sensor array. Initially, at a specific distance, multiple measurements, Gaussian filtering, and averaging are performed on a specific PD signal, to determine the RSSI at this distance, and consequently identify the parameters within the Shadowing model. Subsequently, a centralized and balanced preprocessing of the positioning equation is to be performed. Then, derive regularization parameters through the L-curve method and employ the Tikhonov regularization technique to determine the coordinates of the PD source. Simulations and experiments indicate that under simulated disturbances of 0-15% within a space of 30m × 30m × 20m, the proposed method maintains a positioning error within 3.6m. The method is cost-effective and operationally straightforward.
4 September 2018 in Physical Chemistry Chemical Physics
We performed a comprehensive first-principles study on the structural and electronic properties of ZnSe two-dimensional (2D) nanosheets and their derived one-dimensional (1D) nanoribbons (NRs) and nanotubes (NTs).
11 October 2023 in IET Generation, Transmission & Distribution
With the development of smart meters and other intelligent electronic devices, more and more data‐driven fault location methods based on wide area measurement are emerging. However, these diagnostic methods for dealing with the whole tested system often appear complex. This paper presents an innovative subsystems‐based fault location strategy in distribution grid by the sparsity promoted Bayesian learning algorithm. To avoid taking measurement for the whole distribution system, the fault‐included subsystem is selected according to the distribution characteristics of negative sequence voltage. Then the data for fault location is measured by allocating meters in subsystem, which can reduce the number of required meters. For accurately estimating the fault location, a sparse prior is proposed for the Bayesian learning, which could improve the accuracy of the fault location algorithm by about 4%. The performance is tested on a 12.66‐kV, 69‐bus distribution system in response to various fault scenarios. The results show that the accuracy of the proposed method for the fault section location can reach 90%. It also verifies the robustness and accuracy for fault line location, faced different fault types, fault resistance, noise, etc.