Mark E. Ambühl

Mark E. Ambühl

Auto-generated profile, based on publicly available information

Mark E. Ambühl

Société Des Produits Nestlé S.A. Nestlé Research, Route du Jorat 57, Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2016 in Nature Physics
Verified
Journal Article
Closed access
FRFranck Raynaud
Franck Raynaud
MAMark E. Ambühl
Mark E. Ambühl
CGChiara Gabella
Chiara Gabella
ABAlicia Bornert
Alicia Bornert
ISIvo F. Sbalzarini
Ivo F. Sbalzarini
AVAlexander B. Verkhovsky
Alexander B. Verkhovsky

9 June 2022 in Journal of Food Engineering
Verified
Journal Article
Closed access
SMSarah E.S. Michel
Sarah E.S. Michel
RSRoos Scheermeijer
Roos Scheermeijer
MAMark Ambühl
Mark Ambühl
IFIsabel Fernández Farrés
Isabel Fernández Farrés

20 February 2024 in Journal of Food Engineering
Verified
Journal Article
Open access
KKK. Kramm
K. Kramm
ARA. Roucher
A. Roucher
JDJ. Busom Descarrega
J. Busom Descarrega
MAM. Ambühl
M. Ambühl
JKJ. Kammerhofer
J. Kammerhofer
SHS. Heinrich
S. Heinrich

29 May 2026 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
IJIsabel S. Jüngling
Isabel S. Jüngling
LSLucas Schmitt
Lucas Schmitt
FFFilippo De Franceschi
Filippo De Franceschi
PFPaulo A. Da Costa Filho
Paulo A. Da Costa Filho
LLLei Lei
Lei Lei
NINatalia P. Ivleva
Natalia P. Ivleva
Microplastics (1 µm-5 mm) and nanoplastics (<1 µm) are emerging contaminants with potential health implications, requiring reliable detection for risk assessment. Raman microspectroscopy offers combined morphological and chemical information for identifying micro- and nanoplastics (MNPs). This study assesses the feasibility of automated Raman microspectroscopy for detecting and quantifying MNPs down to 500 nm, focusing on suitable filter materials and device precision. Among six tested filters, silicon filters with 1 µm pores (for particles ≥1 µm) and aluminum-coated polycarbonate filters with 0.4 µm pores (Al-PC, for particles ≥500 nm) performed best. They provided strong particle contrast, low background interference, and high Hit Quality Index (HQI) for submicron particles (polystyrene 500 nm beads, median HQI ≈ 91%), outperforming other filters affected by roughness and spectral interference. Automation using open-source software TUM-ParticleTyper 2 with Random Window Sampling enabled unbiased detection and quantification of MNPs down to 500 nm. Several limitations were noted: illumination settings influenced detected particle number and size recognition, with particles oversized by 0.5 µm ± 0.26 µm; stage precision (~100 nm) affected spectral quality and particle number (90% correct material identification. Validation with 500 nm polystyrene beads yielded 67 ± 10% recovery relative to theoretical values. Analysis of potable water samples showed predominantly non-plastic particles, with only 0.36 ± 0.13% in the 0.5-10 µm range identified as plastics, 18% of them <1 µm. Further method development, particularly for sample preparation, will be required for broader application to water and food samples. For interest only in particles ≥1 µm, filters with pore size closer 1 µm (e.g., silicon) are recommended. Overall, automated Raman microspectroscopy can quantitatively analyze MNPs down to 500 nm, supporting improved plastic exposure risk assessment.

4 February 2026 in Soft Matter
Verified
Journal Article
Open access
PDF file
YLYuechuan Lin
Yuechuan Lin
JDJosep Busom Descarrega
Josep Busom Descarrega
IGIlaria Gaiani
Ilaria Gaiani
STSidhanth Tyagi
Sidhanth Tyagi
HLHans Jörg Limbach
Hans Jörg Limbach
ABAdam S. Burbidge
Adam S. Burbidge
A new method combines SEM imaging, deep learning, and a robust stereological algorithm to resolve sub-micron pore distributions in powders, outperforming X-ray tomography resolution.