Sumathy Muniamuthu

Sumathy Muniamuthu

Auto-generated profile, based on publicly available information

Sumathy Muniamuthu

Department of Mechanical Engineering, Vel Tech Rangarajan Dr.Sagunthala R&D Institute of Science and Technology, Tamil Nadu, India

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Journal of Ecological Engineering
Verified
Journal Article
Open access
SKSUNIL KUMAR KUMAR K
SUNIL KUMAR KUMAR K
SMSumathy Muniamuthu
Sumathy Muniamuthu
AMA. Mohan
A. Mohan
PAP. Amirthalingam
P. Amirthalingam
MMM. Anbu Muthuraja
M. Anbu Muthuraja
This analysis focused on investigating thermal storage behaviour on phase change material along with Al2O3 as an additive. The experimental investigation was performed by three set temperature points, i.e. 40οC, 50οC and 60οC with the mass circulation rate through the tank of 5 kg/min, 3...


6 December 2023 in International Journal of Ambient Energy
Verified
Journal Article
Closed access
SKSUNIL KUMAR KUMAR K
SUNIL KUMAR KUMAR K
SMSumathy Muniamuthu
Sumathy Muniamuthu

1 May 2022 in Ecological Engineering & Environmental Technology
Verified
Journal Article
Open access
SKSUNIL KUMAR KUMAR K
SUNIL KUMAR KUMAR K
SMSumathy Muniamuthu
Sumathy Muniamuthu
BTB.T. Tharanisrisakthi
B.T. Tharanisrisakthi
The present research work deals with the design and fabrication of windmill using venturi effect. The venturi effect is achieved such a way that the propeller rotation is increased about four times for the wind velocity in the surroundings. For any direction of wind flow, the propeller is...

4 August 2023 in Journal of Thermal Engineering
Verified
Journal Article
Closed access
PDF file
KKK Sunıl KUMAR
K Sunıl KUMAR
SMSumathy Muniamuthu
Sumathy Muniamuthu
KMKala Raja Mohan
Kala Raja Mohan
This research work is mainly focused on the performance of the wind turbine power plant. The performance of the plant will depends on the working of wind turbine gearbox. Hence the parameters taken like inlet velocity of air, inlet temperatures and inlet pressure of the air entering into the gearbox. For experimentation a three stage gearbox has been considered and the data has been recorded for the period of 5 months. These results has been recorded with the help of SCADA software and the results are imported from SCADA for analyzing the minimum and maximum oil temperatures. Since these parameters effects directly on the thermal performance of the wind turbine power plant. From the analysis it was found that the temperature sensors for monitoring the oil TM1 and TM2 within temperature limits of 250οC and also the TS1 and TS2 Promises the sensing capacity within temperature limits up to 200 οC and response time is 30 minutes, also the coupling temperatures TC1 and TC2 gives very promising results upto 150 οC for 30 minutes response time.

19 February 2025 in Engineering Research Express
Verified
Journal Article
Open access
SKSUNIL KUMAR KUMAR K
SUNIL KUMAR KUMAR K
SMSumathy Muniamuthu
Sumathy Muniamuthu
Sachin SalunkheSachin Salunkhe
Sachin Salunkhe
Robert ČepRobert Čep
Robert Čep
Emad Abouel NasrEmad Abouel Nasr
Emad Abouel Nasr
The key thrust of this research work is to in-situ Analysis of the drop in Thermal Performance of wind turbine gearbox systems and global challenges and sustainable ideas detection of several failures that occur in the wind turbine gearbox with the help of the latest emerging sensors, and the source of the slave gearbox is a significant input for the master gearbox setup running at 1100 to 1150 rpm at generator side from Jan 2020 to Dec 2020. From the Experimental results, it is clearly understood that the majority of failures occurred due to irregular velocities ranging from 9 to 10 m s−1 at average velocities, and the kinematic viscosities of the oil exceed 400 μ resulting in heavy vibrations resulting in higher maintenance costs. The Master gearbox gives more Predominant results than the Slave gearbox; oil sump temperatures exceeding 85 °C result in poor active power generation falling below 100 Kw, and slave Gearbox oil sump temperatures are achieved at 100 °C; the Maximum temperature attained from the IMS Drive end-stage rate of 85 °C to 90 °C at lower speeds for master gearbox; Whereas slave gearbox temperatures are attained at 110 °C. The average temperature attained from the HSS stage of the Gearbox coupled with the generator is 90 °C, causing heavy vibration frequencies ranging from decibels causing tooth pitting failures for the master gearbox and for the slave gearbox. Average temperatures were attained by 120 °C.