1 October 2018 in Review of Scientific Instruments
The Cherenkov mechanism used in Gas Cherenkov Detectors (GCDs) is exceptionally fast. However, the temporal resolution of GCDs, such as the Gamma Reaction History diagnostic at the National Ignition Facility (NIF), has been limited by the current state-of-the-art photomultiplier tube technology to ∼100 ps. The soon-to-be deployed Pulse Dilation Photomultiplier Tube (PD-PMT) at NIF will allow for temporal resolution comparable to that of the gas cell or ∼10 ps. Enhanced resolution will contribute to the quest for ignition in a crucial way through precision measurements of reaction history and ablator areal density (ρR) history, leading to better constrained models. Features such as onset of alpha heating, shock reverberations, and burn truncation due to dynamically evolving failure modes may become visible for the first time. Test measurements of the PD-PMT at Atomic Weapons Establishment confirmed that design goals have been met. The PD-PMT provides dilation factors of 2 to 40× in 6 increments. The GCD-3 recently deployed at the NIF has been modified for coupling to a PD-PMT and will soon be making ultrafast measurements.
1 June 2018 in Review of Scientific Instruments
A pulse-dilation photomultiplier tube (PD-PMT) with sub-20 ps temporal resolution has been developed for use with γ-ray-sensitive gas Cherenkov detectors at the National Ignition Facility to improve the diagnosis of nuclear fusion burn history and the areal density of the remaining capsule ablator. The pulse-dilation mechanism entails the application of a time-dependent, ramp waveform to a photocathode-mesh structure, introducing a time-dependent photoelectron accelerating potential. The electric field imparts axial velocity dispersion to outgoing photoelectrons. The photoelectron pulse is dilated as it transits a drift region prior to amplification in a microchannel plate and read out with a digital oscilloscope. We report the first measurements with the prototype PD-PMT demonstrating nominal <20 ps FWHM across a 400 ps measurement window and <30 ps FWHM for an extracted charge up to 300 pC. The output peak areas are linear to within 20% over 3 orders of magnitude of input intensity. 3D particle in cell simulations, which included space charge effects, have been carried out to investigate the device temporal magnification, resolution, and linearity.
1 October 2018 in Review of Scientific Instruments
A new ultra-fast photomultiplier tube and associated drivers have been developed for use in the next generation of gamma-ray high pressure gas Cherenkov detectors for inertial confinement fusion experiments at the National Ignition Facility. Pulse-dilation technology has been applied to a standard micro-channel-plate-based photomultiplier tube to improve the temporal response by about 10×. The tube has been packaged suitably for deployment on the National Ignition Facility, and remote electronics have been designed to deliver the required non-linear waveforms to the pulse dilation electrode. This is achieved with an avalanche pulse generator system capable of generating fast arbitrary waveforms over the useful parameter space. The pulse is delivered via fast impedance-matching transformers and isolators, allowing the cathode to be ramped on a sub-nanosecond time scale between two high voltages in a controlled non-linear manner. This results in near linear pulse dilation over several ns. The device has a built-in fiducial system that allows easy calibration and testing with fiber optic laser sources. Results are presented demonstrating the greatly improved response time and other parameters of the device.
1 October 2018 in Review of Scientific Instruments
Fusion reaction history and ablator areal density measurements for Inertial Confinement Fusion experiments at the National Ignition Facility are currently conducted using the Gamma Reaction History diagnostic (GRH_6m). Future Gas Cherenkov Detectors (GCDs) will ultimately provide ∼100x more sensitivity, reduce the effective temporal response from ∼100 to ∼10 ps, and lower the energy threshold from 2.9 to 1.8 MeV, relative to GRH_6m. The first phase toward next generation GCDs consisted of inserting the existing coaxial GCD-3 detector into a reentrant well which puts it within 4 m of the implosion. Reaction history and ablator gamma measurement results from this Phase I are discussed here. These results demonstrate viability for the follow-on Phases of (II) the use of a revolutionary new pulse-dilation photomultiplier tube to improve the effective measurement bandwidth by >10x relative to current PMT technology; and (III) the design of a NIF-specific “Super” GCD which will be informed by the assessment of the radiation background environment within the well described here.
1 August 2018 in Review of Scientific Instruments
A glass Cherenkov detector, called the Diagnostic for Areal Density (DAD), has been built and implemented at the OMEGA laser facility for measuring fusion gammas above 430 keV, from which remaining shell ⟨ρR⟩abl can be determined. A proof-of-principle experiment is discussed, where signals from a surrogate gas Cherenkov detector are compared with reported values from the wedge range filter and charged particle spectrometer and found to correlate strongly. The design of the more compact port–based DAD diagnostic and results from the commissioning shots are then presented. Once absolutely calibrated, the DAD will be capable of reporting remaining shell ⟨ρR⟩abl for plastic and glass capsules within minutes of a shot and with potentially higher precision than existing techniques.
1 January 2021 in Physics of Plasmas
In a number of reported instances, implosions utilizing fuel mixtures have resulted in anomalously low fusion yields below those predicted by radiation-hydrodynamics simulations. Inter-species ion diffusion has been suggested as a possible cause of the observed yield degradation in fuel mixture implosions. An experimental platform utilizing hydro-equivalent deuterium–tritium (DT), deuterium–tritium–hydrogen (DTH), and deuterium-tritium-helium3 (DT3He) capsule implosions was developed to determine whether the inter-species ion diffusion theory may describe the resulting fuel mixture implosion behavior. The implosion experiments were performed at the Omega laser facility. X-ray images and shell areal density diagnostics results show that the hydro-equivalent three capsules (DT, DTH, and DT3He) have similar compression behavior. However, nuclear yield deviation was observed from the scaling determined using a fusion yield formula. In the DT3He mixture, a reduced yield of a factor of 0.65 ± 0.13 was observed, which is similar to a yield reduction observed in D3He mixture by Rygg et al. (i.e., Rygg effect). In contrast, in the DTH mixture, a factor of 1.17 ± 0.15 yield increase was observed, which we named the inverse Rygg effect. The yield increase observed in the DTH mixture is consistent with the inter-species ion diffusion theory where lighter H diffuses away from the core and concentrated DT in the core produces higher yield. An inter-species ion diffusion model, the Zimmerman–Paquette–Kagan–Zhdanov model, implemented in a Lagrangian radiation-hydrodynamics fluid code, was also used to analyze the present data, without the need to assume hydrodynamic equivalence of the capsules, but it does not completely explain the DTH or DT3He capsules although its effects are in the correct direction. Simulation-based Bayesian inference was used in the latter analysis to quantify the uncertainty in the numerical simulations. The simulation-based analysis resulted in an inferred Rygg-effect yield decrease factor of 0.91 ± 0.02 for the DT3He mixture, and an inferred inverse-Rygg yield increase factor of 1.21 ± 0.04 for the DTH mixture, based on simulations ignoring ion diffusion.