Nick Ryckx

Nick Ryckx

Auto-generated profile, based on publicly available information

Nick Ryckx

Institute of Radiation Physics, Lausanne University Hospital, Lausanne, Switzerland

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2017 in Medical Physics
Verified
Journal Article
Closed access
PDF file
MZMichele Zeverino
Michele Zeverino
MJMaud Jaccard
Maud Jaccard
DPDavid Patin
David Patin
NRNick Ryckx
Nick Ryckx
MMMaud Marguet
Maud Marguet
RMRaphaël Moeckli
Raphaël Moeckli

20 November 2019 in European Radiology
Verified
Journal Article
Closed access
PDF file
CAChristoph Aberle
Christoph Aberle
NRNick Ryckx
Nick Ryckx
RTReto Treier
Reto Treier
SSSebastian Schindera
Sebastian Schindera

1 December 2018 in Zeitschrift für Medizinische Physik
Verified
Journal Article
Closed access
TLThiago V.M. Lima
Thiago V.M. Lima
SGSilvano Gnesin
Silvano Gnesin
NRNick Ryckx
Nick Ryckx
KSKlaus Strobel
Klaus Strobel
NSNicolas Stritt
Nicolas Stritt
RLReto Linder
Reto Linder

4 November 2015 in Radiation Protection Dosimetry
Verified
Journal Article
Open access
PDF file
RCRégis Le Coultre
Régis Le Coultre
JBJulie Bize
Julie Bize
MCMélanie Champendal
Mélanie Champendal
DWDavid Wittwer
David Wittwer
NRNick Ryckx
Nick Ryckx
FVFrancis R. Verdun
Francis R. Verdun
In 2013, a nationwide investigation was conducted in Switzerland to establish the population's exposure from medical X rays. A hybrid approach was used combining the Raddose database accessible on-line by the participating practices and the Swiss medical tariffication system for hospitals. This study revealed that the average annual number of examinations is 1.2 per inhabitant, and the associated annual effective dose is 1.4 mSv. It also showed that computed tomography is the most irradiating modality and that it delivers 70 % of the total dose. The annual effective dose per inhabitant registered a 17 % increase in 5 y and is comparable with what was recently reported in neighbouring countries.

1 June 2018 in European Radiology
Verified
Journal Article
Open access
PDF file
DRDamien Racine
Damien Racine
NRNick Ryckx
Nick Ryckx
ABAlexandre Ba
Alexandre Ba
Fabio BecceFabio Becce
Fabio Becce
AVAnais Viry
Anais Viry
SSSabine Schmidt
Sabine Schmidt
Objective We investigated the variability in diagnostic information inherent in computed tomography (CT) images acquired at 68 different CT units, with the selected acquisition protocols aiming to answer the same clinical question. Methods An anthropomorphic abdominal phantom with two optional rings was scanned on 68 CT systems from 62 centres using the local clinical acquisition parameters of the portal venous phase for the detection of focal liver lesions. Low-contrast detectability (LCD) was assessed objectively with channelised Hotelling observer (CHO) using the receiver operating characteristic (ROC) paradigm. For each lesion size, the area under the ROC curve (AUC) was calculated and considered as a figure of merit. The volume computed tomography dose index (CTDIvol) was used to indicate radiation dose exposure. Results The median CTDIvol used was 5.8 mGy, 10.5 mGy and 16.3 mGy for the small, medium and large phantoms, respectively. The median AUC obtained from clinical CT protocols was 0.96, 0.90 and 0.83 for the small, medium and large phantoms, respectively. Conclusions Our study used a model observer to highlight the difference in image quality levels when dealing with the same clinical question. This difference was important and increased with growing phantom size, which generated large variations in patient exposure. In the end, a standardisation initiative may be launched to ensure comparable diagnostic information for well-defined clinical questions. The image quality requirements, related to the clinical question to be answered, should be the starting point of patient dose optimisation. Key Points • Model observers enable to assess image quality objectively based on clinical tasks. • Objective image quality assessment should always include several patient sizes. • Clinical diagnostic image quality should be the starting point for patient dose optimisation. • Dose optimisation by applying DRLs only is insufficient for ensuring clinical requirements.

1 April 2018 in Physica Medica
Verified
Journal Article
Open access
NRNick Ryckx
Nick Ryckx
MSMarta Sans-Merce
Marta Sans-Merce
SSSabine Schmidt
Sabine Schmidt
PPPierre-Alexandre Poletti
Pierre-Alexandre Poletti
FVFrancis R. Verdun
Francis R. Verdun
When performing CT examinations on pregnant patients, great effort should be dedicated towards optimising the exposure of the mother and the conceptus. For this purpose, many radiology departments use high-Z garments to be wrapped around the patient's lower abdomen for out-of-plane organ shielding to protect the fetus. To assess their current protection efficiency, we performed a literature review and compared the efficiencies mentioned in the literature to Monte-Carlo calculations of CT protocols for which the overall scan length was reduced. We found 11 relevant articles, all of them reporting uterus exposure due to CT imaging performed for exclusion of pulmonary embolism, one of the leading causes of peripartum deaths in western countries. Uterus doses ranged between 60 and 660 µGy per examination, and relative dose reductions to the uterus due to high-Z garments were between 20 and 56%. Calculations showed that reducing the scan length by one to three centimetres could potentially reduce uterus dose up to 24% for chest imaging, and even 47% for upper abdominal imaging. These dose reductions were in the order of those achieved by high-Z garments. However, using the latter may negatively influence the diagnostic image quality and even interfere with the automatic exposure control system thus increasing patient dose if positioned in the primary beam, for example in the overranging length in helical acquisition. We conclude that efforts should be concentrated on positioning the patient correctly in the gantry and optimising protocol parameters, rather than using high-Z garments for out-of-plane uterus shielding.