Seong-Hyun Han

Seong-Hyun Han

Auto-generated profile, based on publicly available information

Seong-Hyun Han

Department of Medical Engineering, Graduate School, Kyung Hee University, Seoul 02447, Republic of Korea

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
SHSeong-Hyun Han
Seong-Hyun Han
KMKi Won Moon
Ki Won Moon
YLYun Jong Lee
Yun Jong Lee
GLGi-Ja Lee
Gi-Ja Lee
Accurate and effective diagnosis and individualized management of gout can be potentially achieved by detecting uric acid (UA) and xanthine (XT) simultaneously using an easy-to-use method. Herein, we report simultaneous detection of UA and XT using a 3-dimensional (3D) macroporous gold nanoparticle-incorporated reduced graphene oxide–carbon nanotube nanocomposite (GNP/rGO-CNT). The GNP/rGO-CNT was simply prepared on a glassy carbon electrode (GCE) by one-step electrochemical deposition/co-reduction. It displayed highly sensitive and selective responses to UA and XT, showing excellent stability and good reproducibility in neutral pH. It was demonstrated that 3D GNP/rGO-CNT on GCE could detect UA and XT in human saliva and blood serum simultaneously. This GNP/rGO-CNT for simultaneous detection of UA and XT in human body fluids can be utilized for monitoring drug adherence for gout treatment, together with gout diagnosis.

1 January 2020 in AIP Advances
Verified
Journal Article
Open access
PDF file
JMJinwon Mok
Jinwon Mok
SHSeonghyun Han
Seonghyun Han
HLHyunsook Lee
Hyunsook Lee
It is widely known that abnormal peripheral blood circulation due to intravascular stenosis causes ischemic diseases and blood circulatory disorders. The purpose of this study was to investigate the influence of pulsed magnetic field (PMF) on hemodynamic characteristics in blood vessel with stenosis of 33% with diameter of 15μm, with the change of PMF intensity and hematocrit (Ht) concentration. Stenosed microvascular channels were fabricated using polydimethylsiloxane (PDMS). Our PMF stimulator has the maximum intensity of 2700G at a transition time of 102 μs with pulse intervals of 1Hz. For the Ht altered RBCs suspension, the changes in blood flow and deformation of red blood cells (RBCs) were examined before and after PMF stimulus with various intensity of 200∼2700G. In stenosed channel, threshold intensity for improvement of blood flow seems to be 400G. The higher the Ht, the higher the viscosity and the slower the velocity of RBCs, but after PMF stimulus, RBCs movement overall increased by more than 9∼67% in both Ht 5% and 20% RBCs suspension. Our study shows that PMF plays an important role in in treating cardiovascular diseases with blood circulation disorders caused by narrowing microvascular due to stenosis. In order to extend our results to clinical applications, we need develop more indicators for hemorheologic characteristics such as viscosity and resistance, and need further experiment with diverse PMF condition such as pulse shape, pulse duration, or repetition rate.