Hang Zhang

Hang Zhang

Auto-generated profile, based on publicly available information

Hang Zhang

Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, North China Electric Power University, Baoding 071003, People’s Republic of China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 September 2024 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
WPWang Ping
Wang Ping
WMWenchuang Ma
Wenchuang Ma
HZHang Zhang
Hang Zhang
JGJianghai Geng
Jianghai Geng
YLYunpeng Liu
Yunpeng Liu
ZZZheng Zhong
Zheng Zhong
Air density is an important factors affecting the morphology characteristics of long air gap discharge channels. Analyzing characteristic parameters, such as the propagation velocity and angle of the streamer-leader system at high altitude areas is indispensable in studying the discharge mechanism of long gaps. In this paper, optical images and optical power of the discharge channel were captured. The propagation velocity of the streamer-leader system and angle distribution characteristics of the streamer region were obtained. In accordance with the findings, the downward velocity of the streamer-leader system at low pressure ranges from 1 × 104 to 5 × 104 m s−1. Simultaneously, the velocity decreases slightly under the voltage with a low rise rate, and it is often accompanied by the phenomenon of leader re-luminescence. In addition, the optical images were processed by the pseudo-color algorithm, and the angle of the streamer region of the downward leader head was obtained between 50.3° and 71.6°. The angle of the streamer region is inversely correlated with the voltage rise rate but positively correlated with the gap distance. The results obtained in this paper have academic significance for improving the theoretical system of long gap discharge in high-altitude extreme environments.

1 September 2023 in AIP Advances
Verified
Journal Article
Open access
PDF file
WXWei Xiao
Wei Xiao
BLBing Luo
Bing Luo
LLLei Liu
Lei Liu
ZZZheng Zhong
Zheng Zhong
HZHang Zhang
Hang Zhang
JGJianghai Geng
Jianghai Geng
Southeast Tibet in China is rich in clean energy such as water energy, light energy, and wind energy. As the key means of large-scale clean energy transmission in southeast Tibet, the ultra-high voltage (UHV) power transmission projects will be constructed at an altitude of nearly 4000 m. To accurately acquire the external insulation strength of electrical equipment operating at different altitudes, the standard positive switching impulse voltages were applied to a rod electrode and a 1.1 m diameter shielding sphere at the altitude of 3400, 2100, and 80 m. The switching impulse discharge characterization and altitude correction factors of the 1.1 m diameter shielding sphere-plate gap under different clearances at different altitudes were obtained. The discharge voltage of the rod-plate gap at the altitude of 80 m was corrected to the altitude of 3400 m using altitude correction methods recommended by GB 311.1, GB/T 16927.1, and DL/T 2305. Further comparison was made between the calculation results using the three altitude correction methods mentioned above and the test results at an altitude of 3400 m. The discharge characterization and the minimum clearance of the end fittings of the electrical equipment in the valve hall at the altitude of 3800 and 4500 m were obtained by fitting and extrapolating the test data. The research results provide important reference significance for the external insulation configuration of UHV converter stations constructed in areas with an altitude of 3000 m and above.

10 January 2025 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
JGJianghai Geng
Jianghai Geng
HZHang Zhang
Hang Zhang
WMWenchuang Ma
Wenchuang Ma
WPWang Ping
Wang Ping
YLYunpeng Liu
Yunpeng Liu
ZZZheng Zhong
Zheng Zhong
To better understand the streamer discharge characteristics within the shielding sphere-plate gap in high-altitude converter halls, this study investigates the effects of altitude and surface burrs on discharge parameters during streamer discharge. Tests are conducted at altitudes of 2200 m and 3400 m, utilizing a 1.6 m diameter shielding sphere with a 5 m plate gap under positive polarity impulse conditions. The results reveal that the presence of burrs results in earlier initiation of streamer discharge and smaller increases in optical power during discharge. Moreover, higher altitudes result in earlier initiation of the streamer and a steeper rate of increase in field intensity. Furthermore, the analysis of voltage waveform slope reduction jitter during streamer discharge focuses on the effects of wire corona on voltage wave propagation, the influence of stray capacitance, and the charge injection during streamer. Wire corona reduces voltage wave propagation speed, with relatively minor changes in waveform compared to test data. Comparing different stray capacitance values and corresponding voltage fluctuations reveals increased fluctuation with larger stray capacitance values. Additionally, simulating charge injection during streamer discharge on voltage waveforms through an equivalent circuit yields results consistent with experimental observations. This study provides a data basis for analyzing the factors influencing voltage fluctuations during the streamer period.

27 September 2024
Verified
Conference Paper
Open access
LLLei Liu
Lei Liu
ZZZheng Zhong
Zheng Zhong
HZHang Zhang
Hang Zhang
WMWenchuang Ma
Wenchuang Ma
TLTianjiao Li
Tianjiao Li
JGJianghai Geng
Jianghai Geng
Ultra-high voltage direct current (UHVDC) transmission technology is a key energy transmission technology developed in China. The shielding fittings in the converter station valve hall, a crucial hub, play an important role in electrical load transmission, mechanical load bearing, and electromagnetic protection. However, as transmission projects extend to high-altitude areas in the western regions, reduced air pressure and lower air density lead to decreased insulation strength of the long air gaps between the sphere and the plate in the valve hall. There is an urgent need to study the discharge characteristics in high-altitude environments. In this paper, large-diameter sphere-plate long air gap tests under positive polarity operating impulse voltage were conducted at the Qinghai UHV test base at an altitude of 2,200 meters. By measuring characteristic parameters such as optical power, electric field strength, and current, and analyzing the development characteristics of the 0.6-meter diameter sphere-plate gap based on the experimental dataset and the streamer and discharge development model, the research provides theoretical support for the insulation design and optimization of DC transmission projects.