Anna Wysocka-Rabin

Anna Wysocka-Rabin

Auto-generated profile, based on publicly available information

Anna Wysocka-Rabin

Particle Acceleration Physics and Technology Division, National Centre for Nuclear Research (NCNR) , Poland

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Radiation Measurements
Verified
Journal Article
Closed access
ASA. Szydlowski
A. Szydlowski
MJM. Jaskola
M. Jaskola
AMA. Malinowska
A. Malinowska
SPS. Pszona
S. Pszona
AWA. Wysocka-Rabin
A. Wysocka-Rabin
MKM. Kuk
M. Kuk

1 March 2016 in Nukleonika
Verified
Journal Article
Open access
PDF file
PAPrzemysław Adrich
Przemysław Adrich
RHRadosław Hanke
Radosław Hanke
EKEwa Kulczycka
Ewa Kulczycka
KKKonrad Kosiński
Konrad Kosiński
BMBartosz Meglicki
Bartosz Meglicki
AWAnna Wysocka-Rabin
Anna Wysocka-Rabin
Intraoperative electron radiation therapy (IOERT) is a cancer treatment method that combines oncologic surgery with electron beam radiotherapy. This method can reduce the duration of entire tumor treatment and increase its effectiveness. Moreover, shortening the treatment time significantly reduces the cost and accessibility of the therapy. As a result of interdisciplinary research, an innovative accelerator for IOERT, the IntraLine, was developed. In the course of this work, four patent applications were filed. Today, the work is half way through. In the near future, the device will be optimized. New mechanical design solutions will be developed. Mechanical optimization will significantly reduce the weight of the device. Accelerators control system, which today is in the demo phase, will also be significantly upgraded. This paper describes the stages of the IntraLine accelerator development, its current state and plans for the future R&D work, within the scope of our new Intra-Dose project.

1 October 2011 in Progress in Nuclear Science and Technology
Verified
Journal Article
Closed access
AWAnna Wysocka-Rabin
Anna Wysocka-Rabin
PAPrzemyslaw Adrich
Przemyslaw Adrich
AWAdam Wasilewski
Adam Wasilewski

1 January 2014 in Progress in Nuclear Science and Technology
Verified
Journal Article
Closed access
AWAnna Wysocka-Rabin
Anna Wysocka-Rabin
PAPrzemyslaw Adrich
Przemyslaw Adrich
AWAdam Wasilewski
Adam Wasilewski

9 January 2019 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
JCJoanna Czub
Joanna Czub
JBJanusz Braziewicz
Janusz Braziewicz
MBMarcin Brodecki
Marcin Brodecki
Wojciech GieszczykWojciech Gieszczyk
Wojciech Gieszczyk
MKMariusz Kłosowski
Mariusz Kłosowski
AWAnna Wysocka-Rabin
Anna Wysocka-Rabin
The calibration of low energy X-ray experimental setup with strongly filtered beam dedicated to radiobiological research was performed using the absorbed dose calculated from the data collected by two types detectors. For this purpose a semiconductor (Amptek, USA) and a thermoluminescent (Institute of Nuclear Physics, Krakow, Poland) detectors were applied. The absorbed dose in water values estimated by both detectors are in good agreement.

1 March 2014 in Nukleonika
Verified
Journal Article
Closed access
PDF file
SQSima Qamhiyeh
Sima Qamhiyeh
AWAnna Wysocka-Rabin
Anna Wysocka-Rabin
OJOliver Jäkel
Oliver Jäkel
Better knowledge of CT number values and their uncertainties can be applied to improve heavy ion treatment planning. We developed a novel method to calculate CT numbers for a computed tomography (CT) scanner using the Monte Carlo (MC) code, BEAMnrc/EGSnrc. To generate the initial beam shape and spectra we conducted full simulations of an X-ray tube, filters and beam shapers for a Siemens Emotion CT. The simulation output files were analyzed to calculate projections of a phantom with inserts. A simple reconstruction algorithm (FBP using a Ram-Lak filter) was applied to calculate the pixel values, which represent an attenuation coefficient, normalized in such a way to give zero for water (Hounsfield unit (HU)). Measured and Monte Carlo calculated CT numbers were compared. The average deviation between measured and simulated CT numbers was 4 ± 4 HU and the standard deviation σ was 49 ± 4 HU. The simulation also correctly predicted the behaviour of H-materials compared to a Gammex tissue substitutes. We believe the developed approach represents a useful new tool for evaluating the effect of CT scanner and phantom parameters on CT number values.