Intraoperative electron radiation therapy (IOERT) is a cancer treatment method that combines oncologic surgery with electron beam radiotherapy. This method can reduce the duration of entire tumor treatment and increase its effectiveness. Moreover, shortening the treatment time significantly reduces the cost and accessibility of the therapy. As a result of interdisciplinary research, an innovative accelerator for IOERT, the IntraLine, was developed. In the course of this work, four patent applications were filed. Today, the work is half way through. In the near future, the device will be optimized. New mechanical design solutions will be developed. Mechanical optimization will significantly reduce the weight of the device. Accelerators control system, which today is in the demo phase, will also be significantly upgraded. This paper describes the stages of the IntraLine accelerator development, its current state and plans for the future R&D work, within the scope of our new Intra-Dose project.
1 October 2011 in Progress in Nuclear Science and Technology
The calibration of low energy X-ray experimental setup with strongly filtered beam dedicated to radiobiological research was performed using the absorbed dose calculated from the data collected by two types detectors. For this purpose a semiconductor (Amptek, USA) and a thermoluminescent (Institute of Nuclear Physics, Krakow, Poland) detectors were applied. The absorbed dose in water values estimated by both detectors are in good agreement.
Better knowledge of CT number values and their uncertainties can be applied to improve heavy ion treatment planning. We developed a novel method to calculate CT numbers for a computed tomography (CT) scanner using the Monte Carlo (MC) code, BEAMnrc/EGSnrc. To generate the initial beam shape and spectra we conducted full simulations of an X-ray tube, filters and beam shapers for a Siemens Emotion CT. The simulation output files were analyzed to calculate projections of a phantom with inserts. A simple reconstruction algorithm (FBP using a Ram-Lak filter) was applied to calculate the pixel values, which represent an attenuation coefficient, normalized in such a way to give zero for water (Hounsfield unit (HU)). Measured and Monte Carlo calculated CT numbers were compared. The average deviation between measured and simulated CT numbers was 4 ± 4 HU and the standard deviation σ was 49 ± 4 HU. The simulation also correctly predicted the behaviour of H-materials compared to a Gammex tissue substitutes. We believe the developed approach represents a useful new tool for evaluating the effect of CT scanner and phantom parameters on CT number values.