Tsung-Chieh Yang

Tsung-Chieh Yang

Auto-generated profile, based on publicly available information

Tsung-Chieh Yang

Department of Prosthodontics School of Dentistry National Taiwan University Taipei Taiwan

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2011 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
TYTsung-Chieh Yang
Tsung-Chieh Yang
YMYoshinobu Maeda
Yoshinobu Maeda
TGTomoya Gonda
Tomoya Gonda
SKSunny Kotecha
Sunny Kotecha

16 December 2011 in Clinical Implant Dentistry and Related Research
Verified
Journal Article
Closed access
PDF file
MSMotofumi Sogo
Motofumi Sogo
KIKazunori Ikebe
Kazunori Ikebe
TYTsung‐Chieh Yang
Tsung‐Chieh Yang
MWMasahiro Wada
Masahiro Wada
YMYoshinobu Maeda
Yoshinobu Maeda

29 January 2013 in Journal of Oral Rehabilitation
Verified
Journal Article
Closed access
PDF file
TGT. Gonda
T. Gonda
TYT. C. Yang
T. C. Yang
YMY. Maeda
Y. Maeda

1 January 2013 in The International Journal of Oral and Maxillofacial Implants
Verified
Journal Article
Closed access
TYTsung-Chieh Yang
Tsung-Chieh Yang
YMYoshinobu Maeda
Yoshinobu Maeda
Tsung-Chieh Yang, DDS, PhD/Yoshinobu Maeda, DDS, PhD: Purpose: To evaluate the biomechanical effects of platform switching on external- and internal-connection implants with regard to strain around the implants under loading. Materials and Methods: Implant analogs (5.0 ? 12 mm) with external (EX) and internal (IN) connections were embedded into an acrylic resin block that simulated an edentulous ridge. Abutments with diameters of 5.0, 4.2, and 3.7 mm were attached to EX and IN analogs. A 100-N lateral load was applied to each abutment at an angle of 30 degrees, and the experiments were repeated 10 times. Strain gauges were attached to the implant surface at 1 mm (neck area) and 8 mm (apex area) below the platform to measure the strain around the implant under loading. Statistical analyses were performed by one-way analysis of variance and Steel-Dwass test. P < .05 was considered statistically significant. Results: Significantly higher strain values were found around the neck area in both analogs (EX, ?682.8 με; IN,?582.1 με) with conventional matching 5-mm-diameter abutments, followed by the analogs with 4.2-mm-diameter (EX, ?184.1 με; IN, ?229.1 με) and 3.7-mm-diameter (EX, ?150.5 με; IN, ?129.7 με) platform-switched abutments; this was statistically significant for EX (P < .05). In the apex area, a mild increase in strain was found with a decrease in abutment diameter, but no significant difference was found between 4.2- and 3.7-mm-diameter abutments for IN (P > .05). Conclusion: Within the limitations of this study, platform switching reduced strain surrounding the implant neck area in both EX and IN during loading. However, the decreases in strain values were greater with EX than with IN. Int J Oral Maxillofac Implants 2013;28:143?147. doi: 10.11607/jomi.2305 Key words: external-connection implant, internal-connection implant, platform switching, strain

1 February 2014 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
TYTsung-Chieh Yang
Tsung-Chieh Yang
YMYoshinobu Maeda
Yoshinobu Maeda
TGTomoya Gonda
Tomoya Gonda

1 June 2012 in Implant Dentistry
Verified
Journal Article
Closed access
MSMasashi Dds Sano
Masashi Dds Sano
KIKazunori Dds Ikebe
Kazunori Dds Ikebe
TYTsung-Chieh Dds Yang
Tsung-Chieh Dds Yang
YMYoshinobu Dds Maeda
Yoshinobu Dds Maeda
Purpose: To determine the influence of number and location of implants loaded on the stress to the bone in an edentulous maxilla using a three-dimensional finite element model (3D FEM). Material and Methods: Computed tomographic data with the bone density of a dry skull were used to construct a 3D FEM. Titanium implants were simulated in the configuration as 14 unsplinted implants (US14), 14 splinted implants (S14), 6 splinted implants (canine, premolar, and molar regions, S6), 4 splinted implants (S4), and 6 anterior implants (incisors and canines, A6). Distributed loads of 200 N were applied on the occlusal table of the superstructures. Results: The S6 model was subjected to a similar amount of stress and deformation to the US14 and the S14. The S4 and A6 models were subjected to approximately three times of stress under the vertical load, and approximately five times of stress under the inclined load, respectively, compared with the S6 model. Conclusions: The 3D FEM analyses suggest that the six splinted implants configuration has a similar stress and deformation pattern as compared with naturally positioned splinted 14 implants in the edentulous maxilla.