Objectives. To compare two different forms of mechanical circulatory support (MCS) in patients with complex high-risk indicated PCI (CHIP): the Impella CP system and veno-arterial extracorporeal membrane oxygenation (VA-ECMO). Background. To prevent hemodynamic instability in CHIP, various MCS systems are available. However, comparable data on different forms of MCS are not at hand. Methods. In this multicenter observational study, we retrospectively evaluated all CHIP procedures with the support of an Impella CP or VA-ECMO, who were declined surgery by the heart team. Major adverse cardiac events (MACE), mortality at discharge, and 30-day mortality were evaluated. Results. A total of 41 patients were included, of which 27 patients were supported with Impella CP and 14 patients with VA-ECMO. Baseline characteristics were well-balanced in both groups. No significant difference in periprocedural hemodynamic instability was observed between both groups (3.7% vs. 14.3%; ). The composite outcome of MACE showed no significant difference (30.7% vs. 21.4%; ). Bleeding complications were higher in the Impella CP group, but showed no significant difference (22.2% vs. 7.1%; ) and occurred more at the non-Impella access site. In-hospital mortality was 7.4% in the Impella CP group versus 14.3% in the VA-ECMO group and showed no significant difference ( ). 30-Day mortality showed no significant difference (7.4% vs. 21.4%; ). Conclusions. In patients with CHIP, there were no significant differences in hemodynamic instability and overall MACE between VA-ECMO or Impella CP device as mechanical circulatory support. Based on this study, the choice of either VA-ECMO or Impella CP does not alter the outcome.
26 March 2024 in Journal of the Society for Cardiovascular Angiography & Interventions
Vascular calcification is a hallmark of atherosclerosis and adds considerable challenges for percutaneous coronary intervention (PCI). This review underscores the critical role of coronary computed tomography (CT) angiography in assessing and quantifying vascular calcification for optimal PCI planning. Severe calcification significantly impacts procedural outcomes, necessitating accurate preprocedural evaluation. We describe the potential of coronary CT for calcium assessment and how CT may enhance precision in device selection and procedural strategy. These advancements, along with the ongoing Precise Procedural and PCI Plan study, represent a transformative shift toward personalized PCI interventions, ultimately improving patient outcomes in the challenging landscape of calcified coronary lesions.
Background: The applicability of quantitative flow ratio (QFR), a nonhyperemic, invasive coronary angiography‐derived computation of fractional flow reserve (FFR), has not been studied in coronary artery bypass grafts. We sought to explore the correlation and diagnostic agreement between QFR and FFR in saphenous vein grafts (SVGs). Methods and Results: A total of 129 prospectively included patients (mean age 73±8 years, 84% male) with prior coronary artery bypass grafting underwent invasive coronary angiography and pressure‐derived functional assessment in 150 nonoccluded SVGs. QFR dedicated angiography images of the SVGs were acquired and used for offline QFR computation. The diagnostic performance of QFR was compared with 2‐dimensional quantitative coronary angiography, using FFR as a reference. A threshold of ≤0.80 was used to define functional significance. QFR was successfully computed in 140 (93%) SVGs. We found a significant correlation between QFR and FFR (r=0.72, P <0.001). FFR indicated significant disease in 43 (31%) SVGs, whereas QFR analysis showed significant lesions in 53 (38%) bypass grafts. QFR exhibited a higher sensitivity and diagnostic accuracy compared with angiographic lesion assessment (84% versus 63%, P =0.030 and 83% versus 74%, P =0.036, respectively), whereas specificity did not differ (82% versus 79%, P =0.466). Lastly, QFR demonstrated a higher area under the receiver operating curve than quantitative coronary angiography (0.90 versus 0.82, P =0.008) for the detection of FFR‐defined significant vein graft disease. Conclusions: This study shows the potential applicability of contemporary QFR computation in venous bypass grafts with a moderate correlation and good diagnostic accuracy compared with functional assessment using FFR.
6 December 2024 in Catheterization and Cardiovascular Interventions