1 November 2011 in Géotechnique
Vibrated stone columns are frequently used as a method of reinforcing soft ground as they provide increased bearing capacity and reduce foundation settlements. Their performance in relation to bearing capacity is well documented, but there is also a need for enhanced understanding of their settlement characteristics, particularly in relation to small-group configurations. This paper presents results obtained from physical model tests on triaxial specimens 300 mm in diameter and 400 mm high. Parameters investigated include column length to diameter ratio, area replacement ratio and single/group configuration. The findings of the work are as follows. The design is flexible: settlement can equally be controlled using short columns at relatively high area replacement ratios, or longer columns at smaller area replacement ratios. An optimum area replacement ratio of 30–40% exists for the control of settlement. The settlement performance of a small column group is highly influenced by inter-column and footing interaction effects.
1 September 2007 in Journal of Geotechnical and Geoenvironmental Engineering
This paper investigates the performance of stone columns in a weak deposit such as peat. It evaluates the effects of reinforcing stone columns by jacketing with a tubular wire mesh and bridging reinforcement with a metal rod and a concrete plug. A series of plate loading tests was conducted on isolated stone columns installed in a soil bed consisting of a peat layer sandwiched between two layers of sand. The load–displacement characteristics of footings supported by stone columns were investigated by applying load to a circular plate supported on: (a) untreated soil; (b) soil treated with stone columns; and (c) soil treated with stone columns reinforced with the above reinforcing techniques. The work has shown that the settlement characteristics of the soil can be improved by installing stone columns and that a significant enhancement in the load–settlement response is achieved when the columns are reinforced by the various methods.
1 January 2007 in Canadian Geotechnical Journal
This paper reports an experimental study in which samples of soft kaolin clay (100 mm in diameter and 200 mm in height) were reinforced with vertical columns of sand and tested under triaxial conditions. Samples were reinforced with either a single column of sand of 32 mm diameter or three columns of sand, each of 20 mm diameter. The replacement method was used to form the columns. The columns were installed in the clay to depths of 120 and 200 mm. Tests were also carried out on samples that were not reinforced with sand columns. The samples were compressed under both drained and undrained conditions. It was found that the undrained shear strength of samples containing full-depth columns was greatly improved compared with that of the unreinforced samples. In the fully drained tests, the sample installed with a single column of 32 mm diameter exhibited better performance than the sample with three columns of 20 mm diameter, although the area replacement ratio in the case of the three 20 mm diameter columns was higher than that of the single 32 mm diameter column. However, the undrained strength of the composite material was not particularly affected by the number of columns.Key words: Ground improvement, undrained shear strength, consolidation, stress path, settlement.
1 May 2015 in Measurement
2 October 2014 in Marine Georesources & Geotechnology
This article reports on a series of small-scale, plane strain, 1 g physical model tests designed to investigate the bearing capacity and failure mechanics of end-bearing soil-cement columns formed via Deep Mixing (DM). Pre-formed soil-cement columns, 24 mm in diameter and 200 mm in length, were installed in a soft clay bed using a replacement method; the columns represented improvement area ratios, ap, of 17%, 26%, and 35% beneath a rigid foundation of width 100 mm. Particle Image Velocimetry (PIV) was implemented in conjunction with close-range photogrammetry in order to track soil displacement during loading, from which the failure mechanisms were derived. Bearing capacity performance was verified using Ultimate Limit State numerical analysis, with the results comparing favorably to the analytical static and kinematic solutions proposed by previous researchers. A new equation for bearing capacity was derived from this numerical analysis based on the improvement area ratio and cohesion ratio of the soil column and ground model.
1 October 2014 in Proceedings of the Institution of Civil Engineers - Geotechnical Engineering
Helical screw piles are a popular solution for relatively low-capacity, removable or recyclable foundations supporting road and rail signage or similar light structures. When specifying a helical screw pile, a designer must choose the active length and the helical plate spacing ratio, which are governed by the number, spacing and size of the individual helices. This paper presents an investigation using transparent synthetic soil and particle image velocimetry to observe the failure of helical screw piles with helical plate spacing ratios of 1·5–3 and active lengths up to three times the diameter. For the geometries and properties examined, capacity is shown to be a function of active length and the dominant failure mechanism is characterised by the formation of a cylindrical failure surface. A simple analytical model is developed and used to assess the impact of different design methodologies on immediate displacements under loading. A traditional ‘permissible stress' method is shown to be conservative, whereas modern ‘partial factor' methods are more economical and lead to greater immediate displacements for a given design load. Designers using modern ‘partial factor' approaches, such as Eurocode 7, might benefit from specifying a helical plate spacing ratio of less than 1·5 to maximise the stiffness of the response to axial loading and minimise the immediate displacements experienced upon application of working loads.