To study the wider field (WF) swept-source OCT angiography (SS-OCTA) metrics, especially the nonperfusion area (NPA), in the diagnosing and staging of diabetic retinopathy (DR). Cross-sectional observational study (November 2018 to September 2020). A total of 473 eyes of 286 patients (69 eyes of 49 control patients and 404 eyes of 237 diabetic patients). We imaged using 6 × 6 mm and 12 × 12 mm angiograms on WF SS-OCTA. Images were analyzed using the ARI Network and FIJI ImageJ. Mixed effects multiple regression models and receiver operating characteristic (ROC) analysis were used for statistical analyses. Quantitative metrics such as vessel density (VD); vessel skeletonized density (VSD); foveal avascular zone (FAZ) area, circularity, and perimeter; and NPA in DR and their relative performance for its diagnosis and grading. Among patients with diabetes (median age, 59 years), 51 eyes had no DR, 185 eyes (88 mild, 97 moderate-severe) had nonproliferative DR (NPDR), and 168 eyes had proliferative DR (PDR). Trend analysis revealed a progressive decline in superficial capillary plexus (SCP) VD and VSD, and increased NPA with increasing DR severity. Additionally, there was a significant reduction in deep capillary plexus (DCP) VD and VSD in early DR (mild NPDR), but the progressive reduction in advanced DR stages was not significant. The NPA was the best parameter to diagnose DR (area under the curve [AUC], 0.96), whereas all parameters combined on both angiograms efficiently diagnosed (AUC, 0.97) and differentiated between DR stages (AUC range, 0.83–0.97). The presence of diabetic macular edema was associated with reduced SCP and DCP VD and VSD within mild NPDR eyes, whereas increased VD and VSD in SCP were observed in the moderate-severe NPDR group. Our work highlights the importance of NPA, which can be measured more readily and easily with WF SS-OCTA compared with fluorescein angiography. It is quick and noninvasive, and thus can be an important adjunct for DR diagnosis and management. In our study, a combination of all OCTA metrics on both 6 × 6 mm and 12 × 12 mm angiograms had the best diagnostic accuracy for DR and its severity. Further longitudinal studies are needed to assess NPA as a biomarker for progression or regression of DR severity.
Purpose: Optical coherence tomography angiography (OCT-A) has emerged as a novel tool for the non-invasive imaging and evaluation of the retinal microvasculature. There is little existing literature that compares OCT-A microvasculature metrics across different OCT-A devices in chorioretinal diseases. Herein, we examined these metrics on three available OCT-A platforms. Patients and methods: All subjects were scanned on each of three OCT-A devices: Optovue Avanti Angiovue, Topcon DRI-OCT Triton Swept-Source OCT, and Zeiss Cirrus 5000-HD-OCT Angioplex. Two investigators independently measured foveal avascular zone (FAZ) area. Superficial capillary plexus (SCP) and deep capillary plexus (DCP) vessel densities (VD) were calculated from binarized images with ImageJ software. Image quality across devices was qualitatively compared. Interclass correlation coefficient (ICC), Bland-Altman analysis, repeated measures ANOVA, and post-hoc tests were performed for statistical analysis. Results: Thirteen eyes of seven patients with chorioretinal diagnoses were reviewed. ICC for FAZ measurement was 0.95. There was no significant difference in FAZ area across the three devices (p= 0.792). There was a significant difference in the SCP VD between the OCT-A devices (Triton 0.344 ± 0.013, Angiovue 0.323 ± 0.013, Angioplex 0.367 ± 0.014, p < 0.05). Significantly greater DCP VD was observed with Angioplex (0.385 ± 0.010) in comparison to both Triton (0.331 ± 0.009) and Angiovue (0.341 ± 0.020). A comparison of image quality revealed that Angiovue gives the highest quality, followed by Angioplex and Triton. Conclusion: Core macular microvasculature metrics are now readily accessible on a variety of available OCT-A devices. While the FAZ can be reliably measured across all three devices in this study, there were significant differences for the vessel density in both the SCP and DCP. As a result, clinicians should be careful when comparing microvasculature metrics across different devices when using patient data in multicenter research investigations and clinical trials.
Purpose: During the COVID-19 pandemic, there is growing concern that patients are forgoing necessary care. Emergency departments (ED) represent an important site of eye care. We analyzed patterns of ED visits at an eye-specific ED since the declaration of the public health crisis. Materials and Methods: In this retrospective, cross-sectional single center study, medical records of 6744 patients who presented to the Massachusetts Eye and Ear ED between March 1st and April 30th in 2018, 2019, and 2020 were studied. The primary outcome measures were total volume of ED visits, proportion of urgent ED visits, and proportion of surgical visits. Results: Overall, the median number of daily visits to the ED decreased by 18 visits per day since the declaration of public health guidelines (interquartile range, 9– 24, p < 0.001). This accounted for a 32% decrease in the total volume of ED visits in 2020 compared to prior years during the study period (p < 0.001). There was a 9% increase in the proportion of primary diagnoses considered urgent (p = 0.002). The proportion of visits requiring urgent surgery increased by 39% (p = 0.004). Conclusion: The total number of eye-specific ED visits dropped compared to prior years while the proportion of urgent visits increased. Patients were likely more reluctant to seek eye care, deferring less urgent evaluation.
23 September 2022 in Graefe's Archive for Clinical and Experimental Ophthalmology