Arbai Yusuf

Arbai Yusuf

Auto-generated profile, based on publicly available information

Arbai Yusuf

CTECH Labs, the Center for Tomography Research, Edwar Technology Co. Tangerang, Indonesia

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014
Verified
Conference Paper
Closed access
MHMunnik Haryanti
Munnik Haryanti
AHAbdul Halim
Abdul Halim
AYArbai Yusuf
Arbai Yusuf
Utilization solar panels to generate electricity were increased all over the world including Indonesia. Generally, solar panels mounted on permanent structure which the angle of sunlight direction are fixed. This installation method will reduce the efficiency of electrical energy generated by solar panels due the angle of sun direction changes every time. There are needs equipment that used to steer solar panels toward the sun, namely solar tracking. In this study, we proposed development a prototype of two-axis solar tracking using five photodiodes. Overall, solar tracking system consists of two DC motors, five photodiodes, microcontroller system, and mechanical structure. DC motors are used to driving toward azimuth and elevation, photodiode act as sun-sensor functioned to measure the angle of sunlight direction, microcontroller system functioned to process data and give signal to DC motors. The five photodiodes usage are intended to reduce the cost purchasing of sun-sensor which relatively expensive on the market. Solar tracking prototype has been tested using artificial light with an intensity is closer to the sunlight. Experiment result has shown that this solar tracking is able work very well and can follow the sun movement.

1 October 2012
Verified
Conference Paper
Closed access
WTWarsito P. Taruno
Warsito P. Taruno
MBMarlin Ramadhan Baidillah
Marlin Ramadhan Baidillah
RSRommy I. Sulaiman
Rommy I. Sulaiman
AYArbai Yusuf
Arbai Yusuf
WWWahyu Widada
Wahyu Widada
MAMuhammad Aljohani
Muhammad Aljohani
In this study, we proposed a novel sensor for real time 3D imaging of cancerous mass within human breast using the capacitance measurement method, namely Electrical Capacitance Volume Tomography developed earlier. The sensor works based on the fact that cancerous mass has much higher relative permittivity as compared with normal breast tissue. The electrical capacitance volume tomography (ECVT) imaging technique is capable of generating volumetric image of permittivity distribution of the breast in real time. The 3D sensor constitutes a half-sphere of sensing region to capture the whole permittivity image of the breast. The sensor consists of 24 electrodes with combined triangular and rectangular shapes. Simulated phantoms as well as actual phantom of human breast constituting paraffin as normal human breast tissue and rubber as breast cancer tissue have been used to test the reliability of the sensor system to evaluate the performance of the ECVT technique for breast cancer imaging. The reconstructed images using simulated objects as well as actual measurement using the actual phantom have shown accurate permittivity distributions. The results obtained showed a great feasibility of the 4D tomography imaging as an alternative for a robust and high speed nonradiation technique for breast cancer screening.

1 January 2014 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
IRIrzaman
Irzaman
HSH. Syafutra
H. Syafutra
AAA. Arif
A. Arif
HAHusin Alatas
Husin Alatas
MHM. N. Hilaluddin
M. N. Hilaluddin
TKT. M. Kadri
T. M. Kadri
Growth of Ba 0.5 Sr 0.5 TiO 3 (BST) 1 M thick films are conducted with variation of annealing hold time of 8 hours, 15 hours, 22 hours, and 29 hours at a constant temperature of 850 °C on p-type Si (100) substrate using sol-gel method then followed by spin coating process at 3000 rpm for 30 seconds. The BST thick film electrical conductivity is obtained to be 10−5 to 10−4 S/cm indicate that the BST thick film is classified as semiconductor material. The semiconductor energy band gap value of BST thick film based on annealing hold time of 8 hours, 15 hours, 22 hours, and 29 hours are 2.58 eV, 3.15 eV, 3.2 eV and 2.62 eV, respectively. The I-V photovoltaic characterization shows that the BST thick film is potentially solar cell device, and in accordance to annealing hold time of 8 hours, 15 hours, 22 hours and 29 hours have respective solar cell energy conversion efficiencies of 0.343%, 0.399%, 0.469% and 0.374%, respectively. Optical spectroscopy shows that BST thick film solar cells with annealing hold time of 8 hours, 15 hours, and 22 hours absorb effectively light energy at wavelength of ≥ 700 nm. BST film samples with annealing hold time of 29 hours absorb effectively light energy at wavelength of ≤ 700 nm. The BST thick film refraction index is between 1.1 to 1.8 at light wavelength between ±370 to 870 nm.

1 October 2014
Verified
Conference Paper
Closed access
AYArbai Yusuf
Arbai Yusuf
IMImamul Muttakin
Imamul Muttakin
RRRohmadi Rohmadi
Rohmadi Rohmadi
ARAmir Rudin
Amir Rudin
WWWahyu Widada
Wahyu Widada
WTWarsito P. Taruno
Warsito P. Taruno
Data acquisition system with single signal conditioning for multi-electrode on electrical capacitance volume tomography (ECVT) was described. ECVT is a method in 3D process imaging based on electrical capacitance. The ECVT hardware is employed to measure capacitance signal from 32 electrodes as sensory module. In this investigation, one signal conditioning was used for all electrodes hence hardware construction is simplified and power consumption is relatively low. In order to achieve that, switch configuration which could form analog multiplexer with small resistance and capacitance is required. Each electrode needs 4 analog switches, so that for 32 electrodes 128 analog switches are needed. The electrode is selectable according to desired function as excitation or detection. Experiment result has shown that this ECVT system is able to accomplish capacitance measurement with resolution 0.42 fF.

1 October 2014
Verified
Conference Paper
Closed access
AYArbai Yusuf
Arbai Yusuf
IMImamul Muttakin
Imamul Muttakin
WWWahyu Widada
Wahyu Widada
WTWarsito P. Taruno
Warsito P. Taruno
This research investigates single excitation signal applied on ECVT (electrical capacitance volume tomography) data acquisition system (DAS). ECVT is one of tomography processes based on capacitance measurement. Excitation signals being used in the system are square and sine waves. Single wave excitation signal was injected into pair electrodes which would produce one capacitance measurement. This method lessen the time required to acquire data thus fasten the data acquisition speed. For 16 channels, 138 frame per second could be achieved. The proposed method does not decrease accuracy and sensitivity of capacitance measurement.

1 March 2015 in TELKOMNIKA (Telecommunication Computing Electronics and Control)
Verified
Journal Article
Open access
PDF file
IMImamul Muttakin
Imamul Muttakin
AYArbai Yusuf
Arbai Yusuf
RRRohmadi Rohmadi
Rohmadi Rohmadi
WWWahyu Widada
Wahyu Widada
WTWarsito P. Taruno
Warsito P. Taruno
Design and Simulation of Quadrature Phase Detection in Electrical Capacitance Volume Tomography