26 October 2005 in Experimental Brain Research
22 March 2004 in IEEE Transactions on Biomedical Engineering
Based on recent studies of neuro-adaptive control, we tested a new iterative algorithm to generate custom training forces to "trick" subjects into altering their target-directed reaching movements to a prechosen movement as an after-effect of adaptation. The prechosen movement goal, a sinusoidal-shaped path from start to end point, was never explicitly conveyed to the subject. We hypothesized that the adaptation would cause an alteration in the feedforward command that would result in the prechosen movement. Our results showed that when forces were suddenly removed after a training period of 330 movements, trajectories were significantly shifted toward the prechosen movement. However, de-adaptation occurred (i.e., the after-effect "washed out") in the 50-75 movements that followed the removal of the training forces. A second experiment suppressed vision of hand location and found a detectable reduction in the washout of after-effects, suggesting that visual feedback of error critically influences learning. A final experiment demonstrated that after-effects were also present in the neighborhood of training-44% of original directional shift was seen in adjacent, unpracticed movement directions to targets that were 60/spl deg/ different from the targets used for training. These results demonstrate the potential for these methods for teaching motor skills and for neuro-rehabilitation of brain-injured patients. This is a form of "implicit learning," because unlike explicit training methods, subjects learn movements with minimal instructions, no knowledge of, and little attention to the trajectory.
8 August 2013 in Neurorehabilitation and Neural Repair
Background. Neurorehabilitation studies suggest that manipulation of error signals during practice can stimulate improvement in coordination after stroke. Objective. To test visual display and robotic technology that delivers augmented error signals during training, in participants with stroke. Methods. A total of 26 participants with chronic hemiparesis were trained with haptic (via robot-rendered forces) and graphic (via a virtual environment) distortions to amplify upper-extremity (UE) tracking error. In a randomized crossover design, the intervention was compared with an equivalent amount of practice without error augmentation (EA). Interventions involved three 45-minute sessions per week for 2 weeks, then 1 week of no treatment, and then 2 additional weeks of the alternate treatment. A therapist provided a visual cursor using a tracking device, and participants were instructed to match it with their hand. Haptic and visual EA was used with blinding of participant, therapist, technician-operator, and evaluator. Clinical measures of impairment were obtained at the beginning and end of each 2-week treatment phase as well as at 1 week and at 45 days after the last treatment. Results. Outcomes showed a small, but significant benefit to EA training over simple repetitive practice, with a mean 2-week improvement in Fugl-Meyer UE motor score of 2.08 and Wolf Motor Function Test of timed tasks of 1.48 s. Conclusions. This interactive technology may improve UE motor recovery of stroke-related hemiparesis.
1 June 2009 in IEEE Transactions on Robotics
Many of those who survive a stroke develop a gait disability known as stiff-knee gait (SKG). Characterized by reduced knee flexion angle during swing, people with SKG walk with poor energy efficiency and asymmetry due to the compensatory mechanisms required to clear the foot. Previous modeling studies have shown that knee flexion activity directly before the foot leaves the ground, and this should result in improved knee flexion angle during swing. The goal of this research is to physically test this hypothesis using robotic intervention. We developed a device that is capable of assisting knee flexion torque before swing but feels imperceptible (transparent) for the rest of the gait cycle. This device uses sheathed Bowden cable to control the deflection of a compliant torsional spring in a configuration known as a series elastic remote knee actuator (SERKA). In this investigation, we describe the design and evaluation of SERKA, which includes a pilot experiment on stroke subjects. SERKA could supply a substantial torque (12 N middot m) in less than 20 ms, with a maximum torque of 41 N middot m. The device resisted knee flexion imperceptibly when desired, at less than 1 N middot m rms torque during normal gait. With the remote location of the actuator, the user experiences a mass of only 1.2 kg on the knee. We found that the device was capable of increasing both peak knee flexion angle and velocity during gait in stroke subjects. Thus, the SERKA is a valid experimental device that selectively alters knee kinetics and kinematics in gait after stroke.
1 January 2006 in Journal of Rehabilitation Research and Development
FMFerdinando A. Mussa-Ivaldi
Ferdinando A. Mussa-Ivaldi
We present an initial test of a technique for retraining reaching skills in patients with poststroke hemiparesis, in which errors are temporarily magnified to encourage learning and compensation. Individuals with poststroke hemiparesis held a horizontal plane robotic manipulandum that could exert a variety of forces while recording patients' movements. We measured how well the patients recovered movement straightness in a single visit to the laboratory (approximately 3 h). Following training, we returned forces to zero for an additional 50 movements to discern if aftereffects lasted. We found that all subjects showed immediate benefit from the training, although 3 of the 10 subjects did not retain these benefits for the remainder of the experiment. We discuss how these approaches demonstrate great potential for rehabilitation tools that augment error to facilitate functional recovery.
30 January 2013 in PLOS ONE
We studied reach adaptation to a 30° visuomotor rotation to determine whether augmented error feedback can promote faster and more complete motor learning. Four groups of healthy adults reached with their unseen arm to visual targets surrounding a central starting point. A manipulandum tracked hand motion and projected a cursor onto a display immediately above the horizontal plane of movement. For one group, deviations from the ideal movement were amplified with a gain of 2 whereas another group experienced a gain of 3.1. The third group experienced an offset equal to the average error seen in the initial perturbations, while a fourth group served as controls. Learning in the gain 2 and offset groups was nearly twice as fast as controls. Moreover, the offset group averaged more reduction in error. Such error augmentation techniques may be useful for training novel visuomotor transformations as required of robotic teleoperators or in movement rehabilitation of the neurologically impaired.