Todd. D. Stewart

Todd. D. Stewart

Auto-generated profile, based on publicly available information

Todd. D. Stewart

School of Mechanical Engineering University of Leeds Leeds UK

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2003 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
TSTodd D. Stewart
Todd D. Stewart
Joanne TipperJoanne Tipper
Joanne Tipper
GIGerard Insley
Gerard Insley
RSRobert M. Streicher
Robert M. Streicher
EIEileen Ingham
Eileen Ingham
JFJohn Fisher
John Fisher

1 March 2004 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Closed access
PDF file
JFJ. Fisher
J. Fisher
XHX. Q. Hu
X. Q. Hu
TST. D. Stewart
T. D. Stewart
SWS. Williams
S. Williams
Joanne TipperJoanne Tipper
Joanne Tipper
GBG. Berry
G. Berry

1 December 2001 in Journal of Materials Science: Materials in Medicine
Verified
Journal Article
Closed access
PDF file
TST. Stewart
T. Stewart
Joanne TipperJoanne Tipper
Joanne Tipper
RSR. Streicher
R. Streicher
EIE. Ingham
E. Ingham
JFJ. Fisher
J. Fisher

1 January 2013 in The Bone & Joint Journal
Verified
Journal Article
Closed access
PDF file
AMA. B. McWilliams
A. B. McWilliams
SDS. L. Douglas
S. L. Douglas
ARA. C. Redmond
A. C. Redmond
AGA. J. Grainger
A. J. Grainger
POP. J. O’cOnnor
P. J. O’cOnnor
MSM. H. Stone
M. H. Stone
The results of hip and knee replacement surgery are generally regarded as positive for patients. Nonetheless, they are both major operations and have recognised complications. We present a review of relevant claims made to the National Health Service Litigation Authority. Between 1995 and 2010 there were 1004 claims to a value of £41.5 million following hip replacement surgery and 523 claims to a value of £21 million for knee replacement. The most common complaint after hip surgery was related to residual neurological deficit, whereas after knee replacement it was related to infection. Vascular complications resulted in the highest costs per case in each group. Although there has been a large increase in the number of operations performed, there has not been a corresponding relative increase in litigation. The reasons for litigation have remained largely unchanged over time after hip replacement. In the case of knee replacement, although there has been a reduction in claims for infection, there has been an increase in claims for technical errors. There has also been a rise in claims for non-specified dissatisfaction. This information is of value to surgeons and can be used to minimise the potential mismatch between patient expectation, informed consent and outcome. Cite this article: Bone Joint J 2013;95-B:122–6.

21 October 2003 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
GHG. I. Howling
G. I. Howling
HSH. Sakoda
H. Sakoda
AAA. Antonarulrajah
A. Antonarulrajah
HMH. Marrs
H. Marrs
TST. D. Stewart
T. D. Stewart
EIE. Ingham
E. Ingham

1 April 2002 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Open access
JFJ Fisher
J Fisher
XHX Q Hu
X Q Hu
Joanne TipperJoanne Tipper
Joanne Tipper
TST D Stewart
T D Stewart
SWS Williams
S Williams
EIE Ingham
E Ingham
Although the wear of existing metal-on-metal (MOM) hip prostheses (1 mm3/106 cycles) is much lower than the more widely used polyethylene-on-metal bearings, there are concerns about the toxicity of metal wear particles and elevated metal ion levels, both locally and systemically, in the human body. The aim of this study was to investigate the possibility of reducing the volume of wear, the concentration of metal debris and the level of metal ion release through using surfaceengineered femoral heads. Three thick (8-12 μm) coatings (TiN, CrN and CrCN) and one thin (2 μm) coating (diamond-like carbon, DLC), were evaluated on the femoral heads when articulating against high carbon content cobalt-chromium alloy acetabular inserts (HC CoCrMo) and compared with a clinically used MOM cobalt-chromium alloy bearing couple using a physiological anatomical hip joint simulator (Leeds Mark II). This study showed that CrN, CrCN and DLC coatings produced substantially lower wear volumes for both the coated femoral heads and the HC CoCrMo inserts. The TiN coating itself had little wear, but it caused relatively high wear of the HC CoCrMo inserts compared with the other coatings. The majority of the wear debris for all half-coated couples comprised small, 30 nm or less, CoCrMo metal particles. The Co, Cr and Mo ion concentrations released from the bearing couples of CrN-, CrCN- and DLC-coated heads articulating against HC CoCrMo inserts were at least 7 times lower than those released from the clinical MOM prostheses. These surface-engineered femoral heads articulating on HC CoCrMo acetabular inserts produced significantly lower wear volumes and rates, and hence lower volumetric concentrations of wear particles, compared with the clinical MOM prosthesis. The substantially lower ion concentration released by these surface-engineered components provides important evidence to support the clinical application of this technology.